Estimation of optical properties of turbid media using spatially resolved diffuse reflectance combined with LSTM-attention network

被引:1
|
作者
Sun, Danni [1 ]
Wang, Xin [1 ]
Huang, Min [1 ]
Zhu, Qibing [1 ]
Qin, Jianwei [2 ]
机构
[1] Jiangnan Univ, Key Lab Adv Proc Control Light Ind, Minist Educ, Wuxi 214122, Peoples R China
[2] ARS, USDA, Environm Microbial & Food Safety Lab, Beltsville Agr Res Ctr, Bldg 303,BARC East,10300 Baltimore Ave, Baltimore, MD 20705 USA
基金
中国国家自然科学基金;
关键词
MONTE-CARLO; SCATTERING PROPERTIES; LIGHT TRANSPORT; ABSORPTION; FRUITS;
D O I
10.1364/OE.485235
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The accurate estimation of the optical properties of turbid media by using a spatially resolved (SR) technique remains a challenging task due to measurement errors in the acquired spatially resolved diffuse reflectance (SRDR) and challenges in inversion model implementation. In this study, what we believe to be a novel data-driven model based on a long short-term memory network and attention mechanism (LSTM-attention network) combined with SRDR is proposed for the accurate estimation of the optical properties of turbid media. The proposed LSTM-attention network divides the SRDR profile into multiple consecutive and partially overlaps sub-intervals by using the sliding window technique, and uses the divided sub-intervals as the input of the LSTM modules. It then introduces an attention mechanism to evaluate the output of each module automatically and form a score coefficient, finally obtaining an accurate estimation of the optical properties. The proposed LSTM-attention network is trained with Monte Carlo (MC) simulation data to overcome the difficulty in preparing training (reference) samples with known optical properties. Experimental results of the MC simulation data showed that the mean relative error (MRE) with 5.59% for the absorption coefficient [with the mean absolute error (MAE) of 0.04 cm-1, coefficient of determination (R2) of 0.9982, and root mean square error (RMSE) of 0.058 cm-1] and 1.18% for the reduced scattering coefficient (with an MAE of 0.208 cm-1, R2 of 0.9996, and RMSE of 0.237 cm-1), which were significantly better than those of the three comparative models. The SRDR profiles of 36 liquid phantoms, collected using a hyperspectral imaging system that covered a wavelength range of 530-900 nm, were used to test the performance of the proposed model further. The results showed that the LSTM-attention model achieved the best performance (with the MRE of 14.89%, MAE of 0.022 cm-1, R2 of 0.9603, and RMSE of 0.026 cm-1 for the absorption coefficient; and the MRE of 9.76%, MAE of 0.732 cm-1, R2 of 0.9701, and RMSE of 1.470 cm-1for the reduced scattering coefficient). Therefore, SRDR combined with the LSTM-attention model provides an effective method for improving the estimation accuracy of the optical properties of turbid media.
引用
收藏
页码:10260 / 10272
页数:13
相关论文
共 50 条
  • [41] Noninvasive determination of the optical properties of two-layered turbid media from time-resolved reflectance measurements
    Kienle, A
    Glanzmann, T
    Wagnières, G
    van den Bergh, H
    BIOMEDICAL SENSORS, FIBERS, AND OPTICAL DELIVERY SYSTEMS, PROCEEDINGS, 1999, 3570 : 20 - 27
  • [42] Comparison of spatially and temporally resolved diffuse transillumination measurement systems for extraction of optical properties of scattering media
    Ortiz-Rascon, E.
    Bruce, N. C.
    Garduno-Mejia, J.
    Carrillo-Torres, R.
    Hernandez-Paredes, J.
    Alvarez-Ramos, M. E.
    APPLIED OPTICS, 2017, 56 (33) : 9199 - 9204
  • [43] The determination of in vivo human tissue optical properties and absolute chromophore concentrations using spatially resolved steady-state diffuse reflectance spectroscopy
    Doornbos, RMP
    Lang, R
    Aalders, MC
    Cross, FW
    Sterenborg, HJCM
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (04): : 967 - 981
  • [44] Extraction of optical properties from a turbid medium using fiber probe for spectral and spatial diffuse reflectance measurement
    Rudraiah, Pavitra Sokke
    Duadi, Hamootal
    Fixler, Dror
    OSA CONTINUUM, 2021, 4 (02): : 762 - 773
  • [45] Quantifying the optical properties and chromophore concentrations of turbid media by chemometric analysis of hyperspectral diffuse reflectance data collected using a fourier interferometric imaging system
    Pham, TH
    Eker, C
    Durkin, A
    Tromberg, BJ
    Andersson-Engels, S
    APPLIED SPECTROSCOPY, 2001, 55 (08) : 1035 - 1045
  • [46] Accuracy of PCA-NN in non-invasively determining tissue optical properties from spatially resolved diffuse reflectance
    Chen, YQ
    Lin, L
    Li, G
    Gao, JM
    Wu, KJ
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT II , PTS 1 AND 2, 2005, 5630 : 498 - 509
  • [47] Estimation of the scattering coefficients of turbid media using angle-resolved optical frequency-domain imaging
    Desjardins, A. E.
    Vakoc, B. J.
    Bilenca, A.
    Tearney, G. J.
    Bouma, B. E.
    OPTICS LETTERS, 2007, 32 (11) : 1560 - 1562
  • [48] Reconstruction of optical coefficients in turbid media using time-resolved reflectance and calibration-free instrument response functions
    Helton, Michael
    Mycek, Mary-Ann
    Vishwanath, Karthik
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (03): : 1595 - 1608
  • [49] Regression models for real-time estimation of optical and structural sample properties from subdiffusive spatially resolved reflectance
    Naglic, Peter
    Ivancic, Matic
    Pernus, Franjo
    Likar, Bostjan
    Burmen, Miran
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XXIX, 2018, 10492
  • [50] EXPERIMENTAL TESTS OF A SIMPLE DIFFUSION-MODEL FOR THE ESTIMATION OF SCATTERING AND ABSORPTION-COEFFICIENTS OF TURBID MEDIA FROM TIME-RESOLVED DIFFUSE REFLECTANCE MEASUREMENTS
    MADSEN, SJ
    WILSON, BC
    PATTERSON, MS
    PARK, YD
    JACQUES, SL
    HEFETZ, Y
    APPLIED OPTICS, 1992, 31 (18): : 3509 - 3517