Experimental and numerical analysis of the hygric performance of earthen buildings after facade hydrophobization treatment

被引:3
|
作者
Li, Xiaolong [1 ,2 ]
Zhong, Qiuyang [1 ,2 ]
Tang, Mingfang [1 ,2 ]
Gao, Yafeng [3 ]
Feng, Chi [1 ,2 ]
机构
[1] Chongqing Univ, Sch Architecture & Urban Planning, Chongqing, Peoples R China
[2] Chongqing Univ, Minist Educ, Key Lab New Technol Construct Cities Mt Area, Chongqing, Peoples R China
[3] Chongqing Univ, Sch Civil Engn, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Rammed earth; Hydrophobization treatment; Hygrothermal properties; Indoor humidity; THERMAL-CONDUCTIVITY; RAMMED EARTH; MOISTURE;
D O I
10.1016/j.cscm.2023.e02217
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Earth is used extensively for buildings worldwide, as its thermal properties contribute to a favorable indoor thermal environment. However, earthen materials are sensitive to moisture ingress, which can result in structural damage and undesirable indoor humidity conditions. Through hydrophobization treatment, the capillarity of earth can be significantly reduced while hygroscopicity remains largely unchanged, thereby possibly improving the hygric performance of earthen buildings. In the present study, experiments and simulations were conducted to inves-tigate the effect of hydrophobization on earthen materials and buildings. The experimental results show that the bulk density, open porosity, and pore-size distribution of rammed earth changed by only a few percent after hydrophobization treatment. The thermal properties (thermal conduc-tivity, specific heat capacity, solar reflectivity and longwave emissivity) and hygroscopic prop-erties (sorption isotherm and water vapor permeability) also showed limited changes (< 20 % in most cases). In contrast, capillarity, represented by the capillary absorption coefficient, was reduced by over 80 %. Numerical simulations further showed that relative humidity and moisture content at the exterior and middle positions of earthen walls strongly decreased after hydro-phobization treatment. The largest moisture flux discrepancy between untreated and treated walls was 652.1 g/(h center dot m(2)). Furthermore, the parametric analysis indicated that facade treatment dominated the hygric state of the exterior and middle positions of earthen walls, while ventilation was most important at the wall interior and in the indoor space. Therefore, combining facade hydrophobization treatment and ventilation is recommended to improve the performance of earthen walls and maintain a favorable indoor environment.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Experimental and numerical analysis on hydrodynamic performance of flapping plates
    Zhou, Jun-Wei
    Mei, Lei
    Guo, Bin
    Li, Ming-Yang
    Pan, Xiao-Yun
    Chuan Bo Li Xue/Journal of Ship Mechanics, 2023, 27 (01): : 52 - 69
  • [32] EXPERIMENTAL AND NUMERICAL ANALYSIS OF THERMAL PERFORMANCE IN HEAT PIPES
    Nookaraju, B. Ch
    Rao, P. S. V. Kurma
    Nagasarada, S.
    INTERNATIONAL CONFERENCE ON COMPUTATIONAL HEAT AND MASS TRANSFER (ICCHMT) - 2015, 2015, 127 : 800 - 808
  • [33] Numerical and experimental performance analysis of rotary desiccant wheels
    Yamaguchi, Seiichi
    Saito, Kiyoshi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 60 : 51 - 60
  • [34] Techniques and Experimental Results for Performance Analysis of Photovoltaic Modules Installed in Buildings
    Spertino, F.
    Ahmad, J.
    Ciocia, A.
    Di Leo, P.
    8TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, SEB-16, 2017, 111 : 954 - 963
  • [35] Numerical and experimental analysis of building walls thermal performance
    Al Fakhoury, Joelle
    Sassine, Emilio
    Cherif, Yassine
    Dgheim, Joseph
    Antczak, Emmanuel
    JOURNAL OF BUILDING PHYSICS, 2024, 48 (01) : 5 - 30
  • [36] Experimental study and numerical analysis on seismic performance of steel beam-column damping joint in Chinese traditional style buildings
    Sui, Yan
    He, Zhenhua
    Xue, Jianyang
    Wu, Zhanjing
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (05):
  • [37] Numerical simulation and experimental analysis of springback after ironing
    Zhou, J
    Hu, J
    ADVANCES IN MANUFACTURING TECHNOLOGY - XVII, 2003, : 93 - 99
  • [38] Experimental-numerical research on the seismic performance of URM buildings made of lightweight AAC blocks
    Penna, Andrea
    Rota, Maria
    Mandirola, Martina
    Rosti, Annalisa
    Magenes, Guido
    MAUERWERK, 2015, 19 (02) : 130 - 143
  • [39] Experimental and numerical study on thermal performance of new cool clay tiles in residential buildings in Europe
    Pisello, Anna Laura
    Cotana, Franco
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 1393 - 1398
  • [40] EXPERIMENTAL AND NUMERICAL ANALYSIS OF SOIL-TO-AIR HEAT EXCHANGER SYSTEM FOR DOMESTIC BUILDINGS
    Damodharan, Arunkumar
    Murugan, Ramu
    Abuthakeer, Syath
    THERMAL SCIENCE, 2020, 24 (01): : 603 - 608