Experimental and numerical analysis of the hygric performance of earthen buildings after facade hydrophobization treatment

被引:3
|
作者
Li, Xiaolong [1 ,2 ]
Zhong, Qiuyang [1 ,2 ]
Tang, Mingfang [1 ,2 ]
Gao, Yafeng [3 ]
Feng, Chi [1 ,2 ]
机构
[1] Chongqing Univ, Sch Architecture & Urban Planning, Chongqing, Peoples R China
[2] Chongqing Univ, Minist Educ, Key Lab New Technol Construct Cities Mt Area, Chongqing, Peoples R China
[3] Chongqing Univ, Sch Civil Engn, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Rammed earth; Hydrophobization treatment; Hygrothermal properties; Indoor humidity; THERMAL-CONDUCTIVITY; RAMMED EARTH; MOISTURE;
D O I
10.1016/j.cscm.2023.e02217
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Earth is used extensively for buildings worldwide, as its thermal properties contribute to a favorable indoor thermal environment. However, earthen materials are sensitive to moisture ingress, which can result in structural damage and undesirable indoor humidity conditions. Through hydrophobization treatment, the capillarity of earth can be significantly reduced while hygroscopicity remains largely unchanged, thereby possibly improving the hygric performance of earthen buildings. In the present study, experiments and simulations were conducted to inves-tigate the effect of hydrophobization on earthen materials and buildings. The experimental results show that the bulk density, open porosity, and pore-size distribution of rammed earth changed by only a few percent after hydrophobization treatment. The thermal properties (thermal conduc-tivity, specific heat capacity, solar reflectivity and longwave emissivity) and hygroscopic prop-erties (sorption isotherm and water vapor permeability) also showed limited changes (< 20 % in most cases). In contrast, capillarity, represented by the capillary absorption coefficient, was reduced by over 80 %. Numerical simulations further showed that relative humidity and moisture content at the exterior and middle positions of earthen walls strongly decreased after hydro-phobization treatment. The largest moisture flux discrepancy between untreated and treated walls was 652.1 g/(h center dot m(2)). Furthermore, the parametric analysis indicated that facade treatment dominated the hygric state of the exterior and middle positions of earthen walls, while ventilation was most important at the wall interior and in the indoor space. Therefore, combining facade hydrophobization treatment and ventilation is recommended to improve the performance of earthen walls and maintain a favorable indoor environment.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Experimental Performance and Numerical Simulation of a Thai Modern Facade Wall
    Ananacha, T.
    Puangsombut, W.
    Hirunlabh, J.
    Khedari, J.
    INTERNATIONAL JOURNAL OF VENTILATION, 2015, 14 (03) : 255 - 272
  • [2] Thermal Performance of Multifunctional Facade Solution Containing Phase Change Materials: Experimental and Numerical Analysis
    Amaral, C.
    Gomez, F.
    Moreira, M.
    Silva, T.
    Vicente, R.
    POLYMERS, 2023, 15 (13)
  • [3] A model plan for buildings maintenance with application in the performance analysis of a composite facade cover
    Mendes Silva, J. A. R.
    Falorca, Jorge
    CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (10) : 3248 - 3257
  • [4] Experimental and Numerical Analysis of a PCM-Integrated Roof for Higher Thermal Performance of Buildings
    SIMON Fran?ois
    RUIZ-VALERO Letzai
    GIRARD Aymeric
    GALLEGUILLOS Hector
    JournalofThermalScience, 2024, 33 (02) : 522 - 536
  • [5] Experimental and Numerical Analysis of a PCM-Integrated Roof for Higher Thermal Performance of Buildings
    François Simon
    Letzai Ruiz-Valero
    Aymeric Girard
    Hector Galleguillos
    Journal of Thermal Science, 2024, 33 : 522 - 536
  • [6] Experimental and Numerical Analysis of a PCM-Integrated Roof for Higher Thermal Performance of Buildings
    Simon, Francois
    Ruiz-Valero, Letzai
    Girard, Aymeric
    Galleguillos, Hector
    JOURNAL OF THERMAL SCIENCE, 2024, 33 (02) : 522 - 536
  • [7] Experimental and numerical analysis of heat transfer and airflow on an interactive building facade
    Fuliotto, Roberto
    Cambuli, Francesco
    Mandas, Natalino
    Bacchin, Nicoletta
    Manara, Giampiero
    Chen, Qingyan
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1677 - 1684
  • [8] Experimental and numerical analysis of a naturally ventilated double-skin facade
    Souza, L. C. O.
    Souza, H. A.
    Rodrigues, E. F.
    ENERGY AND BUILDINGS, 2018, 165 : 328 - 339
  • [9] Experimental and numerical analysis of heat transfer and airflow on an interactive building facade
    Fuliotto, Roberto
    Cambuli, Francesco
    Mandas, Natalino
    Bacchin, Nicoletta
    Manara, Giampiero
    Chen, Qingyan
    ENERGY AND BUILDINGS, 2010, 42 (01) : 23 - 28
  • [10] Experimental and Numerical Investigation on Group Anchor Performance of Wooden Bolts in Rammed Earthen Sites
    Wang, Nan
    Zhang, Jingke
    Li, Weihao
    Zhang, Hao
    Wang, Yanwu
    Xu, Hongsheng
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2024,