Evaluation of a calibration rig for stereo laparoscopes

被引:3
|
作者
Dowrick, Thomas [1 ]
Xiao, Guofang [1 ]
Nikitichev, Daniil [1 ]
Dursun, Eren [1 ]
van Berkel, Neils [1 ]
Allam, Moustafa [2 ]
Koo, Bongjin [1 ]
Ramalhinho, Joao [1 ]
Thompson, Stephen [1 ]
Gurusamy, Kurinchi [2 ]
Blandford, Ann [1 ]
Stoyanov, Danail [1 ]
Davidson, Brian R. [2 ]
Clarkson, Matthew J. [1 ]
机构
[1] UCL, Wellcome EPSRC Ctr Intervent & Surg Sci, London, England
[2] UCL Med Sch, Royal Free Hosp, Royal Free Campus, London, England
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
calibration; image-guided surgery; laparascope; stereo; HAND-EYE CALIBRATION; AUGMENTED REALITY; REGISTRATION;
D O I
10.1002/mp.16310
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundAccurate camera and hand-eye calibration are essential to ensure high-quality results in image-guided surgery applications. The process must also be able to be undertaken by a nonexpert user in a surgical setting. PurposeThis work seeks to identify a suitable method for tracked stereo laparoscope calibration within theater. MethodsA custom calibration rig, to enable rapid calibration in a surgical setting, was designed. The rig was compared against freehand calibration. Stereo reprojection, stereo reconstruction, tracked stereo reprojection, and tracked stereo reconstruction error metrics were used to evaluate calibration quality. ResultsUse of the calibration rig reduced mean errors: reprojection (1.47 mm [SD 0.13] vs. 3.14 mm [SD 2.11], p-value 1e-8), reconstruction (1.37 px [SD 0.10] vs. 10.10 px [SD 4.54], p-value 6e-7), and tracked reconstruction (1.38 mm [SD 0.10] vs. 12.64 mm [SD 4.34], p-value 1e-6) compared with freehand calibration. The use of a ChArUco pattern yielded slightly lower reprojection errors, while a dot grid produced lower reconstruction errors and was more robust under strong global illumination. ConclusionThe use of the calibration rig results in a statistically significant decrease in calibration error metrics, versus freehand calibration, and represents the preferred approach for use in the operating theater.
引用
收藏
页码:2695 / 2704
页数:10
相关论文
共 50 条
  • [41] A Smart Rig for Calibration of Gas Sensor Nodes
    Benammar, Mohieddine A.
    Ahmad, Sabbir H. M.
    Abdaoui, Abderrazak
    Tariq, Hasan
    Touati, Farid
    Al-Hitmi, Mohammed
    Crescini, Damiano
    SENSORS, 2020, 20 (08)
  • [42] Differential SfM and image correction for a rolling shutter stereo rig
    Fan, Bin
    Dai, Yuchao
    Zhang, Zhiyuan
    Wang, Ke
    IMAGE AND VISION COMPUTING, 2022, 124
  • [43] WHAT CAN BE SEEN IN 3 DIMENSIONS WITH AN UNCALIBRATED STEREO RIG
    FAUGERAS, OD
    LECTURE NOTES IN COMPUTER SCIENCE, 1992, 588 : 564 - 578
  • [44] Structure from omnidirectional stereo rig motion for city modeling
    Havlena, Michal
    Pajdla, Tomas
    Cornelis, Kurt
    VISAPP 2008: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON COMPUTER VISION THEORY AND APPLICATIONS, VOL 2, 2008, : 407 - +
  • [45] Stereo-rig Design: Lens Selection - Part 3
    Reu, Phillip
    EXPERIMENTAL TECHNIQUES, 2013, 37 (01) : 1 - 3
  • [46] Stereo-rig design: Lens selection—part 3
    Phillip Reu
    Experimental Techniques, 2013, 37 : 1 - 3
  • [47] Automatic detection and tracking of pedestrians from a moving stereo rig
    Schindler, Konrad
    Ess, Andreas
    Leibe, Bastian
    Van Gool, Luc
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2010, 65 (06) : 523 - 537
  • [48] Calibration of binocular stereo measurement system based on calibration cross
    Sun, Nan
    Zhang, Liyan
    Ye, Nan
    Wang, Hongtao
    Guangxue Xuebao/Acta Optica Sinica, 2012, 32 (04):
  • [49] Stereo Camera Calibration with an Embedded Calibration Device and Scene Features
    Qin, Xiameng
    Yang, Jiaolong
    Liang, Wei
    Pei, Mingtao
    Jia, Yunde
    2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO 2012), 2012,
  • [50] TILT CALIBRATION FOR STEREO-MICROSCOPY
    MARTIN, M
    RYDER, DA
    DAVIES, TJ
    METALLOGRAPHY, 1976, 9 (02): : 157 - 165