The Influence of Transtibial Prosthesis Type on Lower-Body Gait Adaptation: A Case Study

被引:2
|
作者
Cherni, Yosra [1 ,2 ]
Laurendeau, Simon [2 ,3 ]
Robert, Maxime [1 ,2 ]
Turcot, Katia [2 ,3 ]
机构
[1] Laval Univ, Dept Rehabil, Quebec City, PQ G1V 0A6, Canada
[2] Ctr Interdisciplinary Res Rehabil & Social Integra, Quebec City, PQ G1M 2S8, Canada
[3] Laval Univ, Dept Kinesiol, Quebec City, PQ G1V 0A6, Canada
关键词
prosthetic devices; artificial limbs; gait rehabilitation; gait symmetry; transtibial amputation; WEIGHT-BEARING ASYMMETRY; LOWER-LIMB AMPUTATION; KNEE OSTEOARTHRITIS; FUNCTIONAL MOBILITY; SUPPORT; WALKING; AMPUTEES; ANKLE; FOOT; INDIVIDUALS;
D O I
10.3390/ijerph20010439
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Gait parameters are altered and asymmetrical in individuals with transtibial amputation. The purpose of this study was to evaluate and compare the effect of four different prosthetic feet on lower-limb biomechanics during gait. A 34-year-old man with transtibial amputation performed four gait analysis sessions with four foot-ankle prostheses (Variflex, Meridium, Echelon, and Kinterra). Kinematic and kinetic parameters and gait symmetry were analyzed in different prosthetic conditions. The type of prosthesis had little effect on the participant's spatiotemporal parameters. Throughout the stance phase, increased hip angle, reduced knee flexion and ankle dorsiflexion were observed in the amputated leg. For kinetic parameters, reduced propulsive force (SI = 0.42-0.65), reduced knee extension moment (mainly during Echelon and Kinterra conditions, SI = 0.17 and 0.32, respectively), and increased knee abduction moment (mainly during the Variflex and Meridium, SI = 5.74 and 8.93, respectively) were measured in the amputated leg. Lower support moments were observed in the amputated leg as compared to the unaffected leg, regardless of the type of prosthesis (SI = 0.61-0.80). The prostheses tested induced different lower-limb mechanical adaptations. In order to achieve the clinical goal of better gait symmetry between lower limbs, an objective gait analysis could help clinicians to prescribe prosthetic feet based on quantitative measurement indicators to optimize gait rehabilitation.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Influence of passive lower-body heating on muscle metabolic perturbation and high-intensity exercise tolerance in humans
    Bailey, Stephen J.
    Wilkerson, Daryl P.
    Fulford, Jonathan
    Jones, Andrew M.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (10) : 3569 - 3576
  • [32] Influence of footwear, foot-strike pattern and step frequency on spatiotemporal parameters and lower-body stiffness in running
    Jaen-Carrillo, Diego
    Garcia-Pinillos, Felipe
    Latella, Christopher
    Moore, Stephanie R.
    Carton-Llorente, Antonio
    Roche-Seruendo, Luis E.
    JOURNAL OF SPORTS SCIENCES, 2022, 40 (03) : 299 - 309
  • [33] Skating sprint performance and the influence of lower-body strength and power in professional and junior elite ice hockey athletes
    Laakso, Lassi A. A.
    Secomb, Josh L. L.
    SPORTS BIOMECHANICS, 2023,
  • [34] Influence of passive lower-body heating on muscle metabolic perturbation and high-intensity exercise tolerance in humans
    Stephen J. Bailey
    Daryl P. Wilkerson
    Jonathan Fulford
    Andrew M. Jones
    European Journal of Applied Physiology, 2012, 112 : 3569 - 3576
  • [35] Does IMU redundancy improve multi-body optimization results to obtain lower-body kinematics? A preliminary study says no
    Couvertier, Marien
    Pacher, Leonie
    Fradet, Laetitia
    JOURNAL OF BIOMECHANICS, 2024, 168
  • [36] The Influence of Multiple Pregnancies on Gait Asymmetry: A Case Study
    Lefranc, Aude S.
    Klute, Glenn K.
    Neptune, Richard R.
    JOURNAL OF APPLIED BIOMECHANICS, 2023, 39 (06) : 403 - 414
  • [37] Influence Of Unweighting On Muscle Oxygenation And Vo2 During Running On A Lower-body Positive-pressure Treadmill
    Farina, Kathryn A.
    Zambito, Allie R.
    Sunderland, Kyle L.
    Smoliga, James M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 948 - 948
  • [38] Using embedded prosthesis sensors for clinical gait analyses in people with lower limb amputation: A feasibility study
    Manz, Sabina
    Seifert, Dirk
    Altenburg, Bjoern
    Schmalz, Thomas
    Dosen, Strahinja
    Gonzalez-Vargas, Jose
    CLINICAL BIOMECHANICS, 2023, 106
  • [39] EFFECT OF SYNCHRONIZED, SYSTOLIC, LOWER-BODY, POSITIVE PRESSURE ON HEMODYNAMICS IN HUMAN SEPTIC SHOCK - A PILOT-STUDY
    GUNTER, JP
    DEBOISBLANC, BP
    RUST, BS
    JOHNSON, WD
    SUMMER, WR
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 151 (03) : 719 - 723
  • [40] The effect of prosthetic alignment on lower limb kinetics in people with a transtibial bone-anchored prosthesis: An experimental within-subject study
    Groeneveld, Alyssa M. G.
    Jonkergouw, Niels
    Bruijn, Sjoerd M.
    Houdijk, Han
    Kooiman, Vera G. M.
    Leijendekkers, Ruud A.
    Prins, Maarten R.
    GAIT & POSTURE, 2025, 117 : 274 - 282