The effect of surgical change to hip geometry on hip biomechanics after primary total hip arthroplasty

被引:4
|
作者
Bahl, Jasvir S. [1 ]
Arnold, John B. [2 ,3 ]
Saxby, David J. [4 ]
Taylor, Mark [5 ]
Solomon, Lucian B. [1 ,6 ]
Thewlis, Dominic [1 ,6 ]
机构
[1] Univ Adelaide, Ctr Orthopaed & Trauma Res COTR, Adelaide Med Sch, Adelaide, SA, Australia
[2] Univ South Australia, Allied Hlth & Human Performance Unit, Alliance Res Exercise Nutr & Act ARENA, Adelaide, SA, Australia
[3] Univ South Australia, Allied Hlth & Human Performance Unit, IIMPACT Hlth, Adelaide, SA, Australia
[4] Griffith Univ, Griffith Ctr Biomed & Rehabil Engn GCORE, Menzies Hlth Inst Queensland, Gold Coast, Qld, Australia
[5] Flinders Univ S Australia, Coll Sci & Engn, Med Device Res Inst, Adelaide, SA, Australia
[6] Royal Adelaide Hosp, Dept Orthopaed & Trauma, Adelaide, SA, Australia
基金
英国医学研究理事会;
关键词
hip biomechanics; hip geometry; musculoskeletal model; simulation; ABDUCTOR MUSCLE STRENGTH; FEMORAL OFFSET; ORIENTATION; DISLOCATION; POSITION;
D O I
10.1002/jor.25455
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of this study was to determine the effect of surgical change to the acetabular offset and femoral offset on the abductor muscle and hip contact forces after primary total hip arthroplasty (THA) using computational methods. Thirty-five patients undergoing primary THA were recruited. Patients underwent a computed tomography scan of their pelvis and hip, and underwent gait analysis pre- and 6-months postoperatively. Surgically induced changes in acetabular and femoral offset were used to inform a musculoskeletal model to estimated abductor muscle and hip joint contact forces. Two experiments were performed: (1) influence of changes in hip geometry on hip biomechanics with preoperative kinematics; and (2) influence of changes in hip geometry on hip biomechanics with postoperative kinematics. Superior and medial placement of the hip centre of rotation during THA was most influential in reducing hip contact forces, predicting 63% of the variance (p < 0.001). When comparing the preoperative geometry and kinematics model, with postoperative geometry and kinematics, hip contact forces increased after surgery (0.68 BW, p = 0.001). Increasing the abductor lever arm reduced abductor muscle force by 28% (p < 0.001) and resultant hip contact force by 17% (0.6 BW, p = 0.003), with both preoperative and postoperative kinematics. Failure to increase abductor lever arm increased resultant hip contact force 11% (0.33 BW, p < 0.001). In conclusion, increasing the abductor lever arm provides a substantial biomechanical benefit to reduce hip abductor and resultant hip joint contact forces. The magnitude of this effect is equivalent to the average increase in hip contact force seen with improved gait from pre-to post-surgery.
引用
收藏
页码:1240 / 1247
页数:8
相关论文
共 50 条
  • [41] Total hip arthroplasty after hip joint gunshot injury
    Pazarci, Ozhan
    Kilinc, Seyran
    Camurcu, Yalkin
    Bulut, Okay
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (03)
  • [42] Is convention hip precaution necessary after total hip arthroplasty?
    Chan, Vincent W. K.
    Chan, M. T.
    Chan, P. K.
    Yan, C. H.
    Chiu, K. Y.
    [J]. JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2021, 28
  • [43] Study of hip joint dislocation after total hip arthroplasty
    Toshinori Masaoka
    Kengo Yamamoto
    Takaaki Shishido
    Yoichi Katori
    Tatsuro Mizoue
    Hideo Shirasu
    Daisuke Nunoda
    [J]. International Orthopaedics, 2006, 30 : 26 - 30
  • [44] Hip Arthroplasty After Surgical Treatment of Intertrochanteric Hip Fractures
    Yuan, Brandon J.
    Abdel, Matthew P.
    Cross, William W.
    Berry, Daniel J.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (11): : 3438 - 3444
  • [45] DO CONVERSION TOTAL HIP ARTHROPLASTY YIELD COMPARABLE RESULTS TO PRIMARY TOTAL HIP ARTHROPLASTY?
    Chin, G.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2016, 64 (01) : 262 - 262
  • [46] Study of hip joint dislocation after total hip arthroplasty
    Masaoka, T
    Yamamoto, K
    Shishido, T
    Katori, Y
    Mizoue, T
    Shirasu, H
    Nunoda, D
    [J]. INTERNATIONAL ORTHOPAEDICS, 2006, 30 (01) : 26 - 30
  • [47] Total hip arthroplasty after failed fixation of hip fractures
    Kyle, Richard F.
    Cooper, Jessica
    [J]. ORTHOPEDICS, 2006, 29 (09) : 783 - 784
  • [48] Total Hip Arthroplasty in the Ankylosed Hip
    Swanson, Megan A.
    Huo, Michael H.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2011, 19 (12) : 737 - 745
  • [49] Approaches to the hip for total hip arthroplasty
    Abdulkareem, I. H.
    [J]. SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2013, 11 (01): : 56 - 56
  • [50] Implant survival after primary total hip arthroplasty due to childhood hip disorders Results from the Danish Hip Arthroplasty Registry
    Thillemann, Theis M.
    Pedersen, Alma B.
    Johnsen, Sren P.
    Sballe, Kjeld
    [J]. ACTA ORTHOPAEDICA, 2008, 79 (06) : 769 - 776