关键词
PHR sensor; self-field; disk arrays; permeability; ROOM-TEMPERATURE; MAGNETORESISTANCE;
D O I
10.4283/JKMS.2023.33.2.076
中图分类号
O59 [应用物理学];
学科分类号
摘要
In order to analyze the permeability measurement performance of the PHR sensor, Type A and Type B sensors with different driving current directions were fabricated. In Type A and B sensors, the magnetic field dependence of the PHR signal V and the signal by self-field V was measured, and these results were well agreed with the calculated results by single domain model. In particular, V was reflected the magnetic sensitivity of Vf, and increased as much as AV by the NiFe disk array specimen placed on the sensor. The permeability measurement performance of Type A and B sensors obtained from AV were high resolution of Ap= 0.45 and 0.75, respectively.
引用
收藏
页码:76 / 81
页数:6
相关论文
共 50 条
  • [41] Optical fiber current sensor for HVDC pole line current measurement
    Yan, Z
    Li, HB
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 7, 2005, : 28 - 30
  • [42] Plasma current measurement at JET using polarimetry-current sensor
    Leysen, W.
    Gusarov, A.
    Wuilpart, M.
    Beaumont, P.
    Boboc, A.
    Croft, D.
    Bekris, N.
    Batistoni, P.
    FUSION ENGINEERING AND DESIGN, 2020, 160
  • [43] Optical fiber current sensor for HVDC pole line current measurement
    College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
    Gaoya Dianqi, 2006, 4 (293-294+297):
  • [44] Straight Driving Improvement of Mobile Robot Using Fuzzy/Current Sensor
    Yoon, Ha-Neul
    Kim, Dong-Eon
    Choi, Byeong-Chan
    Lee, Min-Chul
    Lee, Jang-Myung
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2016, PT I, 2016, 9834 : 343 - 350
  • [45] Design of an EMT-TMR Sensor Array for the Measurement of Magnetic Permeability
    Wang C.
    Zou P.
    Cui Z.
    He H.
    Cao Q.
    Wang H.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2019, 52 (06): : 559 - 567
  • [46] Sensitivity Measurement of the Piezoelectric Paint Sensor according to the Poling Electric Field
    Han, Dae-Hyun
    Park, Seung-Bok
    Kang, Lae-Hyong
    COMPOSITES RESEARCH, 2014, 27 (04): : 146 - 151
  • [47] The effect of electrical parameters of eddy current sensor on metal film thickness measurement performance and the optimization method
    Li, Hongkai
    Wang, Jinlong
    Zhang, Tong
    Li, Zihan
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (10):
  • [48] One small step in the right direction for MRI measurement performance
    Hunter, D. J.
    OSTEOARTHRITIS AND CARTILAGE, 2009, 17 (05) : 557 - 558
  • [49] The impact of the performance measurement systems in setting the 'direction' in the University of Warwick
    Tapinos, E
    Dyson, RG
    Meadows, M
    PRODUCTION PLANNING & CONTROL, 2005, 16 (02) : 189 - 198
  • [50] The validity and reliability of a novel app for the measurement of change of direction performance
    Balsalobre-Fernandez, Carlos
    Bishop, Chris
    Vicente Beltran-Garrido, Jose
    Cecilia-Gallego, Pau
    Cuenca-Amigo, Aleix
    Romero-Rodriguez, Daniel
    Madruga-Parera, Marc
    JOURNAL OF SPORTS SCIENCES, 2019, 37 (21) : 2420 - 2424