A novel method for evaluating combined component anteversion in total hip arthroplasty on cross-table lateral hip radiographs

被引:1
|
作者
Dimitriou, Dimitris [1 ]
Zindel, Christoph [1 ]
Winkler, Elin [1 ]
Cornaz, Frederic [1 ]
Mazel, Peter [1 ]
Zingg, Patrick O. O. [1 ]
机构
[1] Univ Zurich, Balgrist Univ Hosp, Dept Orthoped, Forchstr 340, CH-8008 Zurich, Switzerland
关键词
Total hip arthroplasty; Femoral anteversion; Acetabular anteversion; Combined anteversion; THA dislocation; ACETABULAR CUP; ORIENTATION; DISLOCATION; RANGE; IMPINGEMENT; POSITION; MOTION; ZONE; WEAR;
D O I
10.1007/s00402-023-04825-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionAccurate measurement of combined component anteversion (CA) is important in evaluating the radiographic outcomes following total hip arthroplasty (THA). The aim of the present study was to evaluate the accuracy and reliability of a novel radiographic method in estimating CA in THA.Materials and methodsThe radiographs and computer tomography of patients who underwent a primary THA were retrospectively reviewed, to measure the radiographic CA (CAr), defined as the angle between a line connecting the center of the femoral head to the most anterior rim of the acetabular cup and a line connecting the center of the femoral head to the base of the femoral head to allow a comparison with the CA measured on the CT (CACT). Subsequently, a computational simulation was performed to evaluate the effect of cup anteversion, inclination, stem anteversion, and leg rotation on the CAr and develop a formula that would correct the CAr according to the acetabular cup inclination based on the best-fit equation.ResultsIn the retrospective analysis of 154 THA, the average CAr_cor, and CACT were 53 +/- 11 degrees and 54 +/- 11 degrees (p > 0.05), respectively. A strong correlation was found between CAr and CACT (r = 0.96, p < 0.001), with an average bias of - 0.5 degrees between CAr_cor and CACT. In the computational simulation, the CAr was strongly affected by the cup anteversion, inclination, stem anteversion, and leg rotation. The formula to convert the CAr to CA_cor was: CA-cor = 1.3*Car - (17* In (Cup Inclination) - 31.ConclusionThe combined anteversion measurement of THA components on the lateral hip radiograph is accurate and reliable, implying that it could be routinely used postoperatively but also in patients with persistent complaints following a THA.
引用
收藏
页码:5977 / 5984
页数:8
相关论文
共 50 条
  • [31] Preoperative planning and postoperative evaluation of total hip arthroplasty that takes combined anteversion
    Imai H.
    Miyawaki J.
    Kamada T.
    Takeba J.
    Mashima N.
    Miura H.
    European Journal of Orthopaedic Surgery & Traumatology, 2016, 26 (5) : 493 - 500
  • [32] Combined Anteversion Technique for the Modified Hardinge Approach in Cementless Total Hip Arthroplasty
    Suksathien, Yingyong
    Tippimanchai, Thanut
    TECHNIQUES IN ORTHOPAEDICS, 2021, 36 (04) : 416 - 420
  • [33] Clinical effects of combined anteversion and offset on postoperative dislocation in total hip arthroplasty
    Hidaka, Ryo
    Matsuda, Kenta
    Nakamura, Shigeru
    Nakamura, Masaki
    Kawano, Hirotaka
    ARTHROPLASTY, 2024, 6 (01)
  • [34] Differences in range of motion with the same combined anteversion after total hip arthroplasty
    Ohmori, Takaaki
    Kabata, Tamon
    Kajino, Yoshitomo
    Taga, Tadashi
    Hasegawa, Kazuhiro
    Inoue, Daisuke
    Yamamoto, Takashi
    Takagi, Tomoharu
    Yoshitani, Junya
    Ueno, Takuro
    Tsuchiya, Hiroyuki
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (05) : 1021 - 1028
  • [35] Revision Total Hip Arthroplasty Using Imageless Navigation With the Concept of Combined Anteversion
    Chang, Jun-Dong
    Kim, In-Sung
    Prabhakar, Sharad
    Mansukhani, Sameer A.
    Lee, Sang-Soo
    Yoo, Je-Hyun
    JOURNAL OF ARTHROPLASTY, 2017, 32 (05): : 1576 - 1580
  • [36] Novel Measure of Acetabular Cup Inclination and Anteversion During Total Hip Arthroplasty
    Walter, William L.
    Baker, Neri A.
    Marsden-Jones, Daniel
    Sadeghpour, Ameneh
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2022, 15 : 1 - 14
  • [37] A Novel Device for Intraoperative Measurement of Stem Anteversion Angle in Total Hip Arthroplasty
    Iwakiri, Kentaro
    Ohta, Yoichi
    Ueno, Shuhei
    Minoda, Yukihide
    Kobayashi, Akio
    Nakamura, Hiroaki
    ARTHROPLASTY TODAY, 2024, 28
  • [38] The validity of a novel radiological method for measuring femoral stem version on anteroposterior radiographs of the hip after total hip arthroplasty
    Weber, M.
    Lechler, P.
    von Kunow, R.
    Voellner, F.
    Keshmiri, A.
    Hapfelmeier, A.
    Grifka, J.
    Renkawitz, T.
    BONE & JOINT JOURNAL, 2015, 97B (03): : 306 - 311
  • [39] A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty
    Aydogan M.
    Burç H.
    Saka G.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (6) : 897 - 903
  • [40] Digital Radiography During Total Hip Arthroplasty: Early Results With a Combined Anteversion Technique
    Wojcik, Jay J.
    Lyons, Steven T.
    ORTHOPEDICS, 2022, 45 (04) : 221 - 226