Regulation intensity assessment of pumped storage units in daily scheduling for renewable energy consumption

被引:14
|
作者
Wang, Ran [1 ]
Yang, Weijia [1 ]
Ji, Liantao [2 ]
Li, Xudong [1 ]
Zhang, ShuShu [1 ,3 ]
Jing, Xiuyan [4 ]
机构
[1] Wuhan Univ, State Key Lab Water Resources & Hydropower Engn S, Wuhan 430072, Peoples R China
[2] China Elect Power Res Inst, Nanjing 210003, Peoples R China
[3] Swiss Fed Inst Technol Lausanne EPFL, Sch Architecture Civil & Environm Engn, Lausanne, Switzerland
[4] State Grid Corp China, Beijing 100032, Peoples R China
关键词
Pumped storage; Regulation intensity; Renewable energy consumption; Quantitative assessment; Optimal scheduling; WIND POWER; HYDRO STORAGE; OPERATION; SOLAR; OPTIMIZATION; PERFORMANCE; STRATEGY; SYSTEMS; PLANTS;
D O I
10.1016/j.seta.2023.103027
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To flexibly consume variable renewable energy (VRE), the pumped storage units are facing severe issues induced by regulation duties (e.g., tear, fatigue, vibrations, etc.). This work aims to assess the regulation intensity of the pumped storage unit (RIPSU) for VRE consumption considering both the power grid and units. Firstly, the definition of RIPSU focusing on source-grid coordination is innovatively proposed. Furthermore, a novel assessment model including five important indicators: number of startups and shutdowns, operation duration of power generation, comprehensive utilization hours, regulation mileage, and operation duration in vibration zones, is recommended in VRE systems with pumped storage (PS). Secondly, taking the minimization of VRE consumption deviation as the objective, a day-ahead scheduling model of the Wind-Photovoltaic-Pumped storage hybrid system is established to optimize operation for a better evaluation. Finally, the feasibility of the assess-ment model is demonstrated by a case study in the Jilin Province of China. The results show that RIPSU will generally increase by approximately 2% to 5% for every 5% rise in VRE consumption. The multiple influencing factors on RIPSU are investigated, including energy consumption demand, resources of VRE, and load demand. The study could support the reliability evaluation in various co-operations of PS and large-scale VRE.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] A prospective assessment of scale effects of energy conversion in ultra-low-head pumped hydro energy storage units
    Wang, Hao
    Wang, Fujun
    Wang, Chaoyue
    Wang, Benhong
    Li, Chenfeng
    Li, Dianji
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2024, 315
  • [32] Pumped hydro energy storage and 100 % renewable electricity for East Asia
    Cheng Cheng
    Andrew Blakers
    Matthew Stocks
    Bin Lu
    [J]. Global Energy Interconnection, 2019, 2 (05) : 387 - 393
  • [33] Optimal Weekly Operation Scheduling on Pumped Storage Hydro Power Plant and Storage Battery Considering Reserve Margin with a Large Penetration of Renewable Energy
    Kumano, J.
    Yokoyama, A.
    [J]. 2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014, : 1120 - 1126
  • [34] Complementary Operations of Multi-renewable Energy Systems with Pumped Storage
    Zhu, Zean
    Wang, Lingling
    Wang, Xu
    Jiang, Chuanwen
    Zhou, Shichao
    Gong, Kai
    [J]. CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2023, 9 (05): : 1866 - 1880
  • [35] Joint scheduling method for pumped storage units and new energy stations considering frequency deviation and voltage stiffness constraints
    Lou, Wei
    Wang, Guoteng
    Xu, Ling
    Zhao, Le
    Huang, Ying
    Xu, Zheng
    Lin, Boyuan
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2024, 44 (11): : 66 - 71
  • [36] Operation scheduling of prosumer with renewable energy sources and storage devices
    Souza, S. M.
    Gil, M.
    Sumaili, J.
    Madureira, A. G.
    Pecas Lopes, J. A.
    [J]. 2016 13TH INTERNATIONAL CONFERENCE ON THE EUROPEAN ENERGY MARKET (EEM), 2016,
  • [37] Residential power scheduling with renewable energy and storage in a smart grid
    Telecommunication Systems, Networks and Services Lab, National Institute of Posts and Telecommunications , 2, Allal El Fassi Avenue, Rabat, Morocco
    [J]. Energy Effic., 8
  • [38] Performance analysis of various hybrid renewable energy systems using battery, hydrogen, and pumped hydro-based storage units
    Awan, Ahmed Bilal
    Zubair, Muhammad
    Sidhu, Guftaar Ahmed Sardar
    Bhatti, Abdul Rauf
    Abo-Khalil, Ahmed G.
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (12) : 6296 - 6321
  • [39] Complementary assessment and design optimization of a hybrid renewable energy system integrated with open-loop pumped hydro energy storage
    Ghandehariun, Samane
    Ghandehariun, Amir M.
    Ziabari, Nima Bahrami
    [J]. RENEWABLE ENERGY, 2024, 227
  • [40] Peak Shaving Benefits Assessment of Renewable Energy Source Considering Joint Operation of Nuclear and Pumped Storage Station
    Gong, Ying
    Tan, Changshu
    Zhang, Yannan
    Yuan, Yiping
    Zhou, Lei
    Li, Yan
    Wang, Jianxue
    [J]. CLEANER ENERGY FOR CLEANER CITIES, 2018, 152 : 953 - 958