High-security automatic path planning of radiofrequency ablation for liver tumors

被引:2
|
作者
Li, Jing [1 ,2 ]
Gao, Huayu [1 ,2 ]
Shen, Nanyan [1 ,2 ]
Wu, Di [5 ]
Feng, Lanyun [3 ,4 ]
Hu, Peng [1 ,2 ]
机构
[1] Shanghai Univ, Shanghai Key Lab Intelligent Mfg & Robot, Shanghai, Peoples R China
[2] Shanghai Univ, Sch Mechatron Engn & Automat, Shanghai, Peoples R China
[3] Fudan Univ, Dept Integrat Oncol, Shanghai Canc Ctr, Shanghai, Peoples R China
[4] Fudan Univ, Shanghai Med Coll, Dept Oncol, Shanghai, Peoples R China
[5] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai, Peoples R China
关键词
Liver tumor; Multi-objective optimization; NSGA-II; Puncture path; THERMAL ABLATION; THERAPY; CANCER;
D O I
10.1016/j.cmpb.2023.107769
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Radiofrequency ablation (RFA) is an effective method for the treatment of liver tumors. Preoperative path planning, which plays a crucial role in RFA treatment, requires doctors to have significant experience and ability. Specifically, correct and highly active preoperative path planning should ensure the safety of the whole puncturing process, complete ablation of tumors and minimal damage to healthy tissues. Methods: In this paper, a high-security automatic multiple puncture path planning method for liver tumors is proposed, in which the optimization of the ablation number, puncture number, target positions and puncture point positions subject to comprehensive clinical constraints are studied. In particular, both the safety of the puncture path and the distribution of ablation ellipsoids are taken into consideration. The influence of each constraint on the safety of the whole puncturing process is discussed in detail. On this basis, the efficiency of the planning method is obviously improved by simplifying the computational data and optimized variables. In addition, the performance and adaptability of the proposed method to large and small tumors are compared and summarized. Results: The proposed method is evaluated on 10 liver tumors of various geometric characteristics from 7 cases. The test results show that the average path planning time and average ablation efficiency are 41.4 s and 60.19%, respectively. For tumors of different sizes, the planning results obtained from the proposed method have similar healthy tissue coverage. Through the clinical evaluation of doctors, the planning results meet the needs of RFA for liver tumors. Conclusions: The proposed method can provide reasonable puncture paths in RFA planning, which is beneficial to ensure the safety and efficiency of liver tumor ablation.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] EFFECT OF PERFUSION RATE ON THE RADIOFREQUENCY ABLATION OF LIVER TUMORS
    Ulucakli, M. Erol
    Lavery, Christopher S.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 3B, 2014,
  • [42] Radiofrequency ablation for the treatment of liver tumors in the caudate lobe
    Seror, O
    Haddar, D
    N'Kontchou, G
    Ajavon, Y
    Trinchet, JC
    Beaugrand, M
    Sellier, N
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (07) : 981 - 990
  • [43] Radiofrequency ablation followed by resection of malignant liver tumors
    Scudamore, CH
    Lee, SI
    Patterson, EJ
    Buczkowski, AK
    July, LV
    Chung, SW
    Buckley, AR
    Ho, SGF
    Owen, DA
    AMERICAN JOURNAL OF SURGERY, 1999, 177 (05): : 411 - 417
  • [44] Percutaneous radiofrequency ablation of sonographically unidentifiable liver tumors
    Minami, Yasunori
    Kudo, Masatoshi
    Chung, Hobyung
    Inoue, Tatsuo
    Takahashi, Shunsuke
    Hatanaka, Kinuyo
    Ueda, Taisuke
    Hagiwara, Hitoshi
    Kitai, Satoshi
    Ueshima, Kuzuomi
    Fukunaga, Toyokazu
    Shiozaki, Hitoshi
    ONCOLOGY, 2007, 72 : 111 - 116
  • [45] Myoglobinuria After Laparoscopic Radiofrequency Ablation of Liver Tumors
    John Rodriguez
    Gurkan Tellioglu
    Allan Siperstein
    Eren Berber
    Journal of Gastrointestinal Surgery, 2010, 14 : 664 - 667
  • [46] Magnetic resonance guidance for radiofrequency ablation of liver tumors
    Clasen, Stephan
    Pereira, Philippe L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (02) : 421 - 433
  • [47] A surgical device for radiofrequency ablation of large liver tumors
    dos Santos, I.
    Correia, D.
    Soares, A. J. M.
    Goes, J. A.
    da Rocha, A. F.
    Schutt, D.
    Haemmerich, D.
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (10) : N59 - N70
  • [48] Radiofrequency ablation of liver tumors (I): biological background
    Vanagas, Tomas
    Gulbinas, Antanas
    Pundzius, Juozas
    Barauskas, Giedrius
    MEDICINA-LITHUANIA, 2010, 46 (01): : 13 - 17
  • [49] Radiofrequency ablation shows promise for inoperable liver tumors
    不详
    ONCOLOGY-NEW YORK, 1999, 13 (10): : 1357 - 1357
  • [50] Use of Semiflexible Applicators for Radiofrequency Ablation of Liver Tumors
    G. Gaffke
    B. Gebauer
    F.D. Knollmann
    T. Helmberger
    J. Ricke
    H. Oettle
    R. Felix
    C. Stroszczynski
    CardioVascular and Interventional Radiology, 2006, 29 : 270 - 275