High-security automatic path planning of radiofrequency ablation for liver tumors

被引:2
|
作者
Li, Jing [1 ,2 ]
Gao, Huayu [1 ,2 ]
Shen, Nanyan [1 ,2 ]
Wu, Di [5 ]
Feng, Lanyun [3 ,4 ]
Hu, Peng [1 ,2 ]
机构
[1] Shanghai Univ, Shanghai Key Lab Intelligent Mfg & Robot, Shanghai, Peoples R China
[2] Shanghai Univ, Sch Mechatron Engn & Automat, Shanghai, Peoples R China
[3] Fudan Univ, Dept Integrat Oncol, Shanghai Canc Ctr, Shanghai, Peoples R China
[4] Fudan Univ, Shanghai Med Coll, Dept Oncol, Shanghai, Peoples R China
[5] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai, Peoples R China
关键词
Liver tumor; Multi-objective optimization; NSGA-II; Puncture path; THERMAL ABLATION; THERAPY; CANCER;
D O I
10.1016/j.cmpb.2023.107769
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Radiofrequency ablation (RFA) is an effective method for the treatment of liver tumors. Preoperative path planning, which plays a crucial role in RFA treatment, requires doctors to have significant experience and ability. Specifically, correct and highly active preoperative path planning should ensure the safety of the whole puncturing process, complete ablation of tumors and minimal damage to healthy tissues. Methods: In this paper, a high-security automatic multiple puncture path planning method for liver tumors is proposed, in which the optimization of the ablation number, puncture number, target positions and puncture point positions subject to comprehensive clinical constraints are studied. In particular, both the safety of the puncture path and the distribution of ablation ellipsoids are taken into consideration. The influence of each constraint on the safety of the whole puncturing process is discussed in detail. On this basis, the efficiency of the planning method is obviously improved by simplifying the computational data and optimized variables. In addition, the performance and adaptability of the proposed method to large and small tumors are compared and summarized. Results: The proposed method is evaluated on 10 liver tumors of various geometric characteristics from 7 cases. The test results show that the average path planning time and average ablation efficiency are 41.4 s and 60.19%, respectively. For tumors of different sizes, the planning results obtained from the proposed method have similar healthy tissue coverage. Through the clinical evaluation of doctors, the planning results meet the needs of RFA for liver tumors. Conclusions: The proposed method can provide reasonable puncture paths in RFA planning, which is beneficial to ensure the safety and efficiency of liver tumor ablation.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A heuristic method for rapid and automatic radiofrequency ablation planning of liver tumors
    Li, Ruikun
    An, Chengyang
    Wang, Shuxin
    Wang, Guisheng
    Zhao, Lifeng
    Yu, Yizhou
    Wang, Lisheng
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (12) : 2213 - 2221
  • [2] A heuristic method for rapid and automatic radiofrequency ablation planning of liver tumors
    Ruikun Li
    Chengyang An
    Shuxin Wang
    Guisheng Wang
    Lifeng Zhao
    Yizhou Yu
    Lisheng Wang
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 2213 - 2221
  • [3] Automatic Radiofrequency Ablation Planning for Liver Tumors With Multiple Constraints Based on Set Covering
    Liang, Libin
    Cool, Derek
    Kakani, Nirmal
    Wang, Guangzhi
    Ding, Hui
    Fenster, Aaron
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (05) : 1459 - 1471
  • [4] Treatment planning and image guidance for radiofrequency ablation of liver tumors
    Zhang, Hui
    Banovac, Filip
    Munuo, Stella
    Campos-Nanez, Enrique
    Abeledo, Hernan
    Cleary, Kevin
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [5] Radiofrequency ablation of liver tumors
    Chong, WK
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2001, 32 (05) : 372 - 374
  • [6] Radiofrequency ablation of liver tumors
    Strasberg, SM
    Linehan, D
    CURRENT PROBLEMS IN SURGERY, 2003, 40 (08)
  • [7] Radiofrequency Ablation of Liver Tumors
    McDermott, Shaunagh
    Gervais, Debra A.
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 2013, 30 (01) : 49 - 55
  • [8] Multi-stage puncture path planning algorithm of ablatin needles for percutaneous radiofrequency ablation of liver tumors
    Luo, Min
    Jiang, Huiyan
    Shi, Tianyu
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 145
  • [9] An artificial intelligence-assisted framework for fast and automatic radiofrequency ablation planning of liver tumors in CT images
    Li, Ruikun
    Xin, Rui
    Wang, Shuxin
    Wang, Guisheng
    Zhao, Lifeng
    Jiang, Huijie
    Wang, Lisheng
    CHINESE JOURNAL OF ACADEMIC RADIOLOGY, 2024, 7 (02) : 137 - 146
  • [10] Virtual radiofrequency ablation of liver tumors
    Villard, C
    Soler, L
    Papier, N
    Agnus, V
    Thery, S
    Gangi, A
    Mutter, D
    Marescaux, J
    SURGERY SIMULATION AND SOFT TISSUE MODELING, PROCEEDINGS, 2003, 2673 : 366 - 374