Design of Electrostatic Aberration Correctors for Scanning Transmission Electron Microscopy

被引:0
|
作者
Ribet, Stephanie M. [1 ,2 ,3 ]
Zeltmann, Steven E. [4 ,5 ]
Bustillo, Karen C. [3 ]
Dhall, Rohan [3 ]
Denes, Peter [6 ]
Minor, Andrew M. [3 ,5 ]
dos Reis, Roberto [1 ,2 ,7 ]
Dravid, Vinayak P. [1 ,2 ,7 ]
Ophus, Colin [3 ]
机构
[1] Northwestern Univ, Dept Mat Sci & Engn, Evanston, IL 60208 USA
[2] Northwestern Univ, Int Inst Nanotechnol, Evanston, IL 60208 USA
[3] Lawrence Berkeley Natl Lab, Natl Ctr Electron Microscopy, Mol Foundry, Berkeley, CA 94720 USA
[4] Cornell Univ, Platform Accelerated Realizat Anal & Discovery Int, Ithaca, NY 14853 USA
[5] Univ Calif Berkeley, Dept Mat Sci & Engn, Berkeley, CA 94720 USA
[6] Lawrence Berkeley Natl Lab, Mol Foundry, Berkeley, CA 94720 USA
[7] Northwestern Univ, NUANCE Ctr, Evanston, IL 60208 USA
基金
美国国家科学基金会;
关键词
4D-STEM; aberration correction; phase plate; scanning transmission electron microscopy; simulation; PHASE PLATE; BEAMS; STEM;
D O I
10.1093/micmic/ozad111
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In a scanning transmission electron microscope (STEM), producing a high-resolution image generally requires an electron beam focused to the smallest point possible. However, the magnetic lenses used to focus the beam are unavoidably imperfect, introducing aberrations that limit resolution. Modern STEMs overcome this by using hardware aberration correctors comprised of many multipole elements, but these devices are complex, expensive, and can be difficult to tune. We demonstrate a design for an electrostatic phase plate that can act as an aberration corrector. The corrector is comprised of annular segments, each of which is an independent two-terminal device that can apply a constant or ramped phase shift to a portion of the electron beam. We show the improvement in image resolution using an electrostatic corrector. Engineering criteria impose that much of the beam within the probe-forming aperture be blocked by support bars, leading to large probe tails for the corrected probe that sample the specimen beyond the central lobe. We also show how this device can be used to create other STEM beam profiles such as vortex beams and probes with a high degree of phase diversity, which improve information transfer in ptychographic reconstructions.
引用
收藏
页码:1950 / 1960
页数:11
相关论文
共 50 条
  • [21] Characteristics and effectiveness of a foil lens for correction of spherical aberration in scanning transmission electron microscopy
    Department of Electronics, School of Engineering, Nagoya University, Nagoya
    464-01, Japan
    不详
    464-01, Japan
    Microsc., 3 (185-192):
  • [22] Phase-contrast imaging in aberration-corrected scanning transmission electron microscopy
    Krumeich, F.
    Mueller, E.
    Wepf, R. A.
    MICRON, 2013, 49 : 1 - 14
  • [23] Aberration-corrected scanning transmission electron microscopy for complex transition metal oxides
    张庆华
    肖东东
    谷林
    Chinese Physics B, 2016, (06) : 5 - 12
  • [24] Characteristics and effectiveness of a foil lens for correction of spherical aberration in scanning transmission electron microscopy
    Hanai, T
    Yoshida, H
    Hibino, M
    JOURNAL OF ELECTRON MICROSCOPY, 1998, 47 (03): : 185 - 192
  • [25] Present and Future Hexapole Aberration Correctors for High-Resolution Electron Microscopy
    Haider, Maximilian
    Mueller, Heiko
    Uhlemann, Stephan
    ADVANCES IN IMAGING AND ELECTRON PHYSICS, VOL 153, 2008, 153 : 43 - +
  • [26] Direct Imaging of Light Elements in Aberration-Corrected Scanning Transmission Electron Microscopy
    Idrobo, J. C.
    Oxley, M. P.
    Walkosz, W.
    Klie, R. F.
    Oeguet, S.
    Mikijelj, B.
    Pennycook, S. J.
    Pantelides, S. T.
    MICROSCOPY AND MICROANALYSIS, 2009, 15 : 1480 - 1481
  • [27] Aberration-corrected scanning transmission electron microscopy for complex transition metal oxides
    Zhang, Qing-Hua
    Xiao, Dong-Dong
    Gu, Lin
    CHINESE PHYSICS B, 2016, 25 (06)
  • [28] Aberration corrected high-resolution transmission and scanning transmission electron microscopy of thin perovskite layers
    Walther, T.
    Ross, I. M.
    EUROPEAN CONFERENCE ON NANO FILMS - ECNF2012, 2013, 40 : 49 - 55
  • [29] Advances in Aberration-Corrected Scanning Transmission Electron Microscopy and Electron Energy-Loss Spectroscopy
    Krivanek, Ondrej L.
    Dellby, Niklas
    Keyse, Robert J.
    Murfitt, Matthew F.
    Own, Christopher S.
    Szilagyi, Zoltan S.
    ADVANCES IN IMAGING AND ELECTRON PHYSICS, VOL 153, 2008, 153 : 121 - +
  • [30] Energy Filtered Scanning Confocal Electron Microscopy in a Double Aberration-Corrected Transmission Electron Microscope
    Wang, P.
    Behan, G.
    Kirkland, A. I.
    Nellist, P. D.
    MICROSCOPY AND MICROANALYSIS, 2009, 15 : 42 - 43