Dosimetric analysis of beam arrangement for intensity-modulated radiation therapy in the postoperative irradiation of thymoma

被引:0
|
作者
Akbas, Canan Koksal [1 ,3 ]
Alveroglu, Gokce Ucar [1 ]
Suncak, Leyla [1 ]
Karaman, Sule [2 ]
Dagoglu, Nergiz [2 ]
Oral, Ethem Nezih [2 ]
Becerir, Hatice Bilge [1 ]
机构
[1] Istanbul Univ, Oncol Inst, Div Med Phys, Istanbul, Turkiye
[2] Istanbul Univ, Div Radiat Oncol, Oncol Inst, Istanbul, Turkiye
[3] Istanbul Univ, Oncol Inst, Millet St Fatih, Istanbul, Turkiye
关键词
Thymoma; Eclipse TPS; IMRT; Beam arrangement; STAGE-III THYMOMA; BREAST-CANCER; RADIOTHERAPY; RISK; MANAGEMENT; DISEASE;
D O I
10.1016/j.radphyschem.2023.111242
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study aimed to investigate the dosimetric effect of various beam arrangements (BAs), for intensity modulated radiotherapy (IMRT) in female thymoma patients. Six-field IMRT plans with three different BAs, named IMRTCA, IMRTCS, and IMRTNC were created for each patient. The couch angles of all fields were selected at 0 degrees, which made the fields coplanar in the axial plane in IMRTCA plans. The couch angles of all fields were selected to be 90 degrees, which makes the fields coplanar in the sagittal plane in IMRTCS plans. The couch angles of the four fields and two fields were selected as 90 degrees and 0 degrees, respectively in IMRTNC plans. Plans were compared in terms of dose homogeneity, conformity, and OAR doses. IMRTCS plans created with coplanar beams in the sagittal plane could offer significant advantages in terms of breast and lung sparing. IMRTCS may be useful for young female thymoma patients to reduce the risk of developing a second cancer in the breast. In addition, it should be considered that IMRTCS contributes approximately 1 Gy to the mean heart dose.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Commentary - Intensity-modulated radiation therapy
    Goffman, TE
    Glatstein, E
    RADIATION RESEARCH, 2002, 158 (01) : 115 - 117
  • [42] Intensity-Modulated Radiation Therapy - Foreword
    Johnstone, PAS
    CURRENT PROBLEMS IN CANCER, 2004, 28 (02) : 46 - 46
  • [43] Does fluence smoothing reduce the complexity of the intensity-modulated radiation therapy treatment plan? A dosimetric analysis
    Saroj, Dinesh Kumar
    Yadav, Suresh
    Paliwal, Neetu
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (04) : 336 - 343
  • [44] A review of intensity-modulated radiation therapy
    Laurie E. Gaspar
    Meisong Ding
    Current Oncology Reports, 2008, 10 : 294 - 299
  • [45] The physics of intensity-modulated radiation therapy
    Boyer, AL
    PHYSICS TODAY, 2002, 55 (09) : 38 - 44
  • [46] A Review of Intensity-Modulated Radiation Therapy
    Gaspar, Laurie E.
    Ding, Meisong
    CURRENT ONCOLOGY REPORTS, 2008, 10 (04) : 294 - 299
  • [47] A multiobjective beam angle optimization framework for intensity-modulated radiation therapy
    de Freitas, Juliana Campos
    Cantane, Daniela Renata
    Rocha, Humberto
    Dias, Joana
    EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2024, 318 (01) : 286 - 296
  • [48] Intensity-modulated particle beam radiation therapy in the management of olfactory neuroblastoma
    Hu, Weixu
    Hu, Jiyi
    Gao, Jing
    Yang, Jing
    Qiu, Xianxin
    Kong, Lin
    Lu, Jiade J.
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (15)
  • [49] Quantification of beam complexity in intensity-modulated radiation therapy treatment plans
    Du, Weiliang
    Cho, Sang Hyun
    Zhang, Xiaodong
    Hoffman, Karen E.
    Kudchadker, Rajat J.
    MEDICAL PHYSICS, 2014, 41 (02)
  • [50] A hybrid approach to beam angle optimization in intensity-modulated radiation therapy
    Bertsimas, D.
    Cacchiani, V.
    Craft, D.
    Nohadani, O.
    COMPUTERS & OPERATIONS RESEARCH, 2013, 40 (09) : 2187 - 2197