Comparative Analysis of Surface Modification Techniques for Assessing Oral Implant Osseointegration: An Animal Study

被引:0
|
作者
Karthik, K. S. [1 ]
Sreevidya, B. [2 ]
Ramya, T. K. [3 ]
Divya, B. M. [4 ]
Dedeepya, N. R. [1 ]
Badiyani, Bhumika Kamal [5 ]
Kumar, Amit [5 ]
机构
[1] KGF Kolar Gold Fields Coll Dent Sci, Dept Prosthodont & Implantol, Kolar, India
[2] KGF Kolar Gold Fields Coll Dent Sci, Dept Oral & Maxillofacial Surg, Kolar, India
[3] KGF Kolar Gold Fields Coll Dent Sci, Dept Oral Med & Radiol, Kolar, India
[4] DA Pandu Mem RV Rashtreeya Vidyalaya Dent Coll, Dept Publ Hlth Dent, Bangalore, Karnataka, India
[5] Interdent Multispecial Dent Clin, Dept Publ Hlth Dent, Mumbai, Maharashtra, India
关键词
implantology; dentistry; surface modifications; osseointegration; implants; TITANIUM DENTAL IMPLANTS; HISTOMORPHOMETRIC EVALUATION; BONE; ROUGHNESS;
D O I
10.7759/cureus.54014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Effective implant placement depends critically on the implant's level of osseointegration with the alveolar bone. To increase osseointegration during implant placement, research has concentrated on the surface modification of implants, and morphological analyses have looked at the thread pattern in close interaction with the bone's surface. Aim: This study aimed to assess and compare the extent of oral implant osseointegration in different surface modification techniques. Materials and methods: In this study, 12 healthy adult dogs aged 18-24 months were used. Tooth extractions were performed on both sides of the mandible, and wounds were closed with sutures. Two months later, the right mandible of each dog underwent local anesthesia and general anesthesia. Four different implant types were placed based on their surface treatments: resorbable blast media (RBM)-treated implants, hydroxyapatite (HA) implants with an ultra -thin HA film, hydrothermal-treated HA implants coated with HA, and sandblasting combined acid etching (SLA) implants treated with plasma spray and acid etching. A total of 48 implants were divided into two- and four -week groups, with identical dimensions. Each dog received two implants from each group, for a total of eight implants per dog. The implants were securely placed into the superior alveolar bone with a torque greater than 35-N up to a depth of 1 mm. Periotest M (Medizintechnik Gulden e.K., Modautal, Germany) was used to calculate the periotest value (PTV) as a typical value on the buccal side of each implant immediately following placement and sacrifice to test the main fixation and stability of the implants. Resonance frequency analysis (RFA) was utilised by Osstell Mentor (Osstell AB, Gothenburg, Sweden) to simultaneously assess the implant stability quotient (ISQ) on the medial, distal, buccal, and lingual sides of the implant. The rotational torque in one of the sacrificed dogs was calculated using the MGT 50 (ELECTROMATIC Equipment Co., Inc., New York, USA) torque analyzer. The histomorphometric evaluation was performed using an optical microscope (Olympus Corporation, Tokyo, Japan). The upper half's bone -implant contact (BIC), which was found to be more important for implant stability, was studied together with the ratio of the new bone formation area (NBFA) to the complete implant. Results: The maximum stability was observed in HA -treated implants in the fourth week. The minimum stability was observed in hydrothermal-treated HA implants in the fourth week. The stability in each group was greater in the four -week evaluation as compared to the two-week evaluation. The stability was satisfactory in almost all implants at two- and three-week evaluations. The maximum value of the percentage area of newly formed bone at the two- and four -week evaluations was observed in HA -treated implants. The minimum value of the percentage of the area of newly formed bone at two- and four -week evaluations was observed in SLA and RBM-treated implants respectively. The difference was significant statistically (p <= 0.05). Conclusion: All implant surface modifications, in general, produced satisfactory osseointegration. Excellent osseointegration was seen in the upper portion of the implant with hydrothermally treated HA.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Fractal analysis as a useful predictor for determining osseointegration of dental implant? A retrospective study
    Emrah Soylu
    Aykağan Coşgunarslan
    Selin Çelebi
    Damla Soydan
    Ahmet Emin Demirbaş
    Osman Demir
    International Journal of Implant Dentistry, 7
  • [42] A comparative study of strontium-substituted hydroxyapatite coating on implant's osseointegration for osteopenic rats
    Tao, Zhou-Shan
    Bai, Bing-Li
    He, Xing-Wen
    Liu, Wei
    Li, Hang
    Zhou, Qiang
    Sun, Tao
    Huang, Zheng-Liang
    Tu, Kai-kai
    Lv, Yang-Xun
    Cui, Wei
    Yang, Lei
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (12) : 1959 - 1968
  • [43] Fractal analysis as a useful predictor for determining osseointegration of dental implant? A retrospective study
    Soylu, Emrah
    Cosgunarslan, Aykagan
    Celebi, Selin
    Soydan, Damla
    Demirbas, Ahmet Emin
    Demir, Osman
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [44] Simple 3,4-Dihydroxy-L-Phenylalanine Surface Modification Enhances Titanium Implant Osseointegration in Ovariectomized Rats
    Ting Ma
    Xi-Yuan Ge
    Ke-Yi Hao
    Bi-Ru Zhang
    Xi Jiang
    Ye Lin
    Yu Zhang
    Scientific Reports, 7
  • [45] Simple 3,4-Dihydroxy-&ITL&IT-Phenylalanine Surface Modification Enhances Titanium Implant Osseointegration in Ovariectomized Rats
    Ma, Ting
    Ge, Xi-Yuan
    Hao, Ke-Yi
    Zhang, Bi-Ru
    Jiang, Xi
    Lin, Ye
    Zhang, Yu
    SCIENTIFIC REPORTS, 2017, 7
  • [46] Implant surface material: A comparative animals study.
    Manor, R
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B310 - B310
  • [47] The Influence of Storage in Saline or Irradiation by Ultraviolet on Surface Hydrophilicity of Implant and Osseointegration: An Experimental Study in Rabbits
    Zhu, Yuhao
    Xu, Antian
    Zhou, Chuan
    Wu, Yefeng
    Lin, Guofen
    He, Fuming
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (01) : 70 - 78
  • [48] Clinical and histological efficacy of a new implant surface in achieving early and stable osseointegration: An in vivo study
    Nevins, Myron
    Chen, Chia-Yu
    Khang, Wahn
    Kim, David M.
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2024, 17 (03)
  • [49] Synergistic effects of implant macrogeometry and surface physicochemical modifications on osseointegration: An in vivo experimental study in sheep
    Bergamo E.T.P.
    de Oliveira P.G.F.P.
    Jimbo R.
    Neiva R.
    Tovar N.
    Witek L.
    Gil L.F.
    Bonfante E.A.
    Coelho P.G.
    Journal of Long-Term Effects of Medical Implants, 2019, 29 (04): : 295 - 302
  • [50] Surface Modification and Surface Melting in Grinding - A Comparative and Comprehensive Study
    Alagumurthi, N.
    Palaniradja, K.
    Soundararajan, V.
    JOURNAL FOR MANUFACTURING SCIENCE AND PRODUCTION, 2006, 7 (02) : 101 - 125