Comparative Analysis of Surface Modification Techniques for Assessing Oral Implant Osseointegration: An Animal Study

被引:0
|
作者
Karthik, K. S. [1 ]
Sreevidya, B. [2 ]
Ramya, T. K. [3 ]
Divya, B. M. [4 ]
Dedeepya, N. R. [1 ]
Badiyani, Bhumika Kamal [5 ]
Kumar, Amit [5 ]
机构
[1] KGF Kolar Gold Fields Coll Dent Sci, Dept Prosthodont & Implantol, Kolar, India
[2] KGF Kolar Gold Fields Coll Dent Sci, Dept Oral & Maxillofacial Surg, Kolar, India
[3] KGF Kolar Gold Fields Coll Dent Sci, Dept Oral Med & Radiol, Kolar, India
[4] DA Pandu Mem RV Rashtreeya Vidyalaya Dent Coll, Dept Publ Hlth Dent, Bangalore, Karnataka, India
[5] Interdent Multispecial Dent Clin, Dept Publ Hlth Dent, Mumbai, Maharashtra, India
关键词
implantology; dentistry; surface modifications; osseointegration; implants; TITANIUM DENTAL IMPLANTS; HISTOMORPHOMETRIC EVALUATION; BONE; ROUGHNESS;
D O I
10.7759/cureus.54014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Effective implant placement depends critically on the implant's level of osseointegration with the alveolar bone. To increase osseointegration during implant placement, research has concentrated on the surface modification of implants, and morphological analyses have looked at the thread pattern in close interaction with the bone's surface. Aim: This study aimed to assess and compare the extent of oral implant osseointegration in different surface modification techniques. Materials and methods: In this study, 12 healthy adult dogs aged 18-24 months were used. Tooth extractions were performed on both sides of the mandible, and wounds were closed with sutures. Two months later, the right mandible of each dog underwent local anesthesia and general anesthesia. Four different implant types were placed based on their surface treatments: resorbable blast media (RBM)-treated implants, hydroxyapatite (HA) implants with an ultra -thin HA film, hydrothermal-treated HA implants coated with HA, and sandblasting combined acid etching (SLA) implants treated with plasma spray and acid etching. A total of 48 implants were divided into two- and four -week groups, with identical dimensions. Each dog received two implants from each group, for a total of eight implants per dog. The implants were securely placed into the superior alveolar bone with a torque greater than 35-N up to a depth of 1 mm. Periotest M (Medizintechnik Gulden e.K., Modautal, Germany) was used to calculate the periotest value (PTV) as a typical value on the buccal side of each implant immediately following placement and sacrifice to test the main fixation and stability of the implants. Resonance frequency analysis (RFA) was utilised by Osstell Mentor (Osstell AB, Gothenburg, Sweden) to simultaneously assess the implant stability quotient (ISQ) on the medial, distal, buccal, and lingual sides of the implant. The rotational torque in one of the sacrificed dogs was calculated using the MGT 50 (ELECTROMATIC Equipment Co., Inc., New York, USA) torque analyzer. The histomorphometric evaluation was performed using an optical microscope (Olympus Corporation, Tokyo, Japan). The upper half's bone -implant contact (BIC), which was found to be more important for implant stability, was studied together with the ratio of the new bone formation area (NBFA) to the complete implant. Results: The maximum stability was observed in HA -treated implants in the fourth week. The minimum stability was observed in hydrothermal-treated HA implants in the fourth week. The stability in each group was greater in the four -week evaluation as compared to the two-week evaluation. The stability was satisfactory in almost all implants at two- and three-week evaluations. The maximum value of the percentage area of newly formed bone at the two- and four -week evaluations was observed in HA -treated implants. The minimum value of the percentage of the area of newly formed bone at two- and four -week evaluations was observed in SLA and RBM-treated implants respectively. The difference was significant statistically (p <= 0.05). Conclusion: All implant surface modifications, in general, produced satisfactory osseointegration. Excellent osseointegration was seen in the upper portion of the implant with hydrothermally treated HA.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Rapid Osseointegration of Titanium Implant With Innovative Nanoporous Surface Modification: Animal Model and Clinical Trial
    Huang, Mao-Suan
    Chen, Li-Kai
    Ou, Keng-Liang
    Cheng, Han-Yi
    Wang, Che-Shun
    IMPLANT DENTISTRY, 2015, 24 (04) : 441 - 447
  • [2] Comparative study on the osseointegration of implants in dog mandibles according to the implant surface treatment
    Yoon, Wook-Jae
    Kim, Su-Gwan
    Oh, Ji-Su
    You, Jae-Seek
    Jeong, Kyung-In
    Lim, Sung-Chul
    Jeong, Mi-Ae
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2016, 42 (06) : 345 - 351
  • [3] Osseointegration of a New, Ultrahydrophilic and Nanostructured Dental Implant Surface: A Comparative In Vivo Study
    Pabst, Andreas
    Asran, Ashraf
    Lueers, Steffen
    Laub, Markus
    Holfeld, Christopher
    Palarie, Victor
    Thiem, Daniel G. E.
    Becker, Philipp
    Hartmann, Amely
    Heimes, Diana
    Al-Nawas, Bilal
    Kaemmerer, Peer W.
    BIOMEDICINES, 2022, 10 (05)
  • [4] Surface Modification Techniques to Enhance Osseointegration of Spinal Implants
    Possley, Daniel
    Baker, Erin
    Baker, Kevin
    Khalil, Jad G.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (22) : E988 - E994
  • [5] Surface modification of bioinert ceramics enhances osseointegration in an animal model
    Schreiner, U
    Schroeder-Boersch, H
    Schwarz, M
    Scheller, G
    BIOMEDIZINISCHE TECHNIK, 2002, 47 (06): : 164 - 168
  • [6] Osseointegration of Plasma Jet Treated Titanium Implant Surface in an Animal Model
    Jang, Min-Ho
    Park, Young-Bum
    Kwon, Jae-Sung
    Kim, Yeun-Ju
    Lee, Jae-Hoon
    MATERIALS, 2021, 14 (08)
  • [7] Comparative analysis of osseointegration in various types of acetabular implant materials
    Bondarenko, Stanislav
    Dedukh, Ninel
    Filipenko, Volodymyr
    Akonjom, Mandus
    Badnaoui, Ahmed Amine
    Schwarzkopf, Ran
    HIP INTERNATIONAL, 2018, 28 (06) : 622 - 628
  • [8] Influence of extracellular matrix coatings on implant stability and osseointegration: An animal study
    Stadlinger, Bernd
    Pilling, Eckart
    Huhle, Matthias
    Mai, Ronald
    Bierbaum, Susanne
    Bernhardt, Ricardo
    Scharnweber, Dieter
    Kuhlisch, Eberhard
    Hempel, Ute
    Eckelt, Uwe
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 83B (01) : 222 - 231
  • [9] Effect of insertion torque on titanium implant osseointegration: an animal experimental study
    Duyck, Joke
    Roesems, Rutger
    Cardoso, Marcio V.
    Ogawa, Toru
    Camargos, Germana De Villa
    Vandamme, Katleen
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (02) : 191 - 196
  • [10] Surface Modification Techniques to Produce Micro/Nano-scale Topographies on Ti-Based Implant Surfaces for Improved Osseointegration
    Hou, Chuang
    An, Jing
    Zhao, Duoyi
    Ma, Xiao
    Zhang, Weilin
    Zhao, Wei
    Wu, Meng
    Zhang, Zhiyu
    Yuan, Fusheng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10