No difference in patient- reported outcomes with cruciate-retaining, anterior-stabilized, and posterior- stabilized total knee arthroplasty designs

被引:0
|
作者
Rehman, Y. [1 ]
Korsvold, A. M. [2 ]
Lerdal, A. [3 ]
Aamodt, A. [1 ]
机构
[1] Lovisenberg Diaconal Hosp, Dept Orthopaed Surg, Oslo, Norway
[2] Lovisenberg Diaconal Hosp, Dept Physiotherapy, Oslo, Norway
[3] Lovisenberg Diaconal Hosp, Dept Res & Dev, Oslo, Norway
来源
BONE & JOINT JOURNAL | 2023年 / 105B卷 / 12期
关键词
REPLACEMENT; LIGAMENT; RETENTION; INJURY; SCORE; HIP;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
<bold>Aims: </bold>This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS).<bold>Methods: </bold>Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale, range of motion (ROM), and willingness to undergo the operation again. Patient satisfaction was also assessed.<bold>Results: </bold>Patients reported similar levels of pain, function, satisfaction, and general health regardless of the prosthetic design they received. Mean maximal flexion (129 degrees (95% confidence interval (CI) 127 degrees to 131 degrees) was greater in the PS group than in the CR (120 degrees (95% CI 121 degrees to 124 degrees)) and AS groups (122 degrees (95% CI 120 degrees to 124 degrees)).<bold>Conclusion: </bold>Despite differences in design and constraint, CR, AS, and PS designs from a single TKA system resulted in no differences in patient-reported outcomes at two-year follow-up. PS patients had statistically better ROM, but the clinical significance of this finding is unclear.
引用
收藏
页码:1271 / 1278
页数:8
相关论文
共 50 条
  • [41] Midterm Outcomes and Survivorship of Anterior Stabilized Versus Cruciate Retaining Bearing in Primary Total Knee Arthroplasty
    Law, Jesua, I
    Hurst, Jason M.
    Morris, Michael J.
    Berend, Keith R.
    Lombardi, Adolph V., Jr.
    Crawford, David A.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (03): : 998 - 1002
  • [42] Joint line changes in cruciate-retaining versus posterior-stabilized computer-navigated total knee arthroplasty
    Bin Abd Razak, Hamid Rahmatullah
    Pang, Hee Nee
    Yeo, Seng Jin
    Tan, Mann Hong
    Lo, Ngai Nung
    Chong, Hwei Chi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (06) : 853 - 859
  • [43] Flexion-Extension Gap in Cruciate-Retaining Versus Posterior-Stabilized Total Knee Arthroplasty: A Cadaveric Study
    Matthews, Joshua
    Chong, Alexander
    McQueen, David
    O'Guinn, Justin
    Wooley, Paul
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (05) : 627 - 632
  • [44] Evaluation of Postoperative Range of Motion and Functional Outcomes after Cruciate-Retaining and Posterior-Stabilized High-Flexion Total Knee Arthroplasty
    Han, Chang Wook
    Yang, Ick Hwan
    Lee, Woo Suk
    Park, Kwan Kyu
    Han, Chang Dong
    YONSEI MEDICAL JOURNAL, 2012, 53 (04) : 794 - 800
  • [45] Kinematics of bicruciate stabilized and cruciate retaining total knee arthroplasty
    Ishibashi, Teruya
    Yamazaki, Takaharu
    Konda, Shoji
    Tamaki, Masashi
    Sugamoto, Kazuomi
    Tomita, Tetsuya
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2022, 40 (07) : 1547 - 1554
  • [46] Posterior stabilized versus cruciate retaining total knee arthroplasty designs: Conformity affects the performance reliability of the design over the patient population
    Ardestani, Marzieh M.
    Moazen, Mehran
    Maniei, Ehsan
    Jin, Zhongmin
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (04) : 350 - 360
  • [47] Influence of the anterior–posterior femoral translation on the range of motion in cruciate-retaining total knee arthroplasty
    Shinya Yanagisawa
    Naoki Sato
    Takashi Ohsawa
    Kenichi Saito
    Masaki Shimizu
    Kenji Takagishi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 2709 - 2714
  • [48] Anteroposterior stability after posterior cruciate-retaining total knee arthroplasty
    A. J. Schuster
    A. L. von Roll
    D. Pfluger
    T. Wyss
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 1113 - 1120
  • [49] Anteroposterior stability after posterior cruciate-retaining total knee arthroplasty
    Schuster, A. J.
    von Roll, A. L.
    Pfluger, D.
    Wyss, T.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (07) : 1113 - 1120
  • [50] Effect of Joint Line Elevation after Posterior-stabilized and Cruciate-retaining Total Knee Arthroplasty on Clinical Function and Kinematics
    Ji Song-Jie
    Zhou Yi-Xin
    Jiang Xu
    Cheng Zhi-Yuan
    Wang Guang-Zhi
    Ding Hui
    Yang Ming-Lei
    Zhu Zhong-Lin
    中华医学杂志英文版, 2015, 128 (21) : 2866 - 2872