A modelling study on the frosting characteristics of a novel dual-fan outdoor coil in an Air Source Heat Pump unit

被引:5
|
作者
Bai, Xiaoxia [1 ]
Liu, Shengnan [1 ]
Deng, Shiming [2 ]
Zhang, Long [3 ]
Wei, Minchen [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Hong Kong, Peoples R China
[2] Qatar Univ, Dept Mech & Ind Engn, POB 2713, Doha, Qatar
[3] Beijing Inst Technol, Sch Mech Engn, Dept Energy & Power Engn, Beijing, Peoples R China
关键词
Air source heat pump; Novel dual -fan outdoor coil; Dynamic mathematical model; Even frosting characteristics; Heating performances; PERFORMANCE; GROWTH; EXCHANGER; FLOW; FIN; TEMPERATURE; PREDICTION; DEFROST;
D O I
10.1016/j.applthermaleng.2022.119933
中图分类号
O414.1 [热力学];
学科分类号
摘要
Uneven frosting along the airflow direction in a traditional outdoor coil in air source heat pumps (ASHPs) was inevitable due to a fixed one-way outdoor airflow direction, causing a rapid deterioration in heating performances of ASHPs. To alleviate this uneven frosting phenomenon, a novel dual-fan outdoor coil where air flow direction can be alternately reversed was proposed in a previous experimental study. To more effectively and comprehensively study the operating characteristics of ASHPs having the dual-fan outdoor coil at different fan operating modes, with different configurations and under different operating ambient conditions, a dynamic mathematical model for the experimental ASHP having the dual-fan outdoor coil was developed and experimentally validated. Then a follow-up modelling study for different operating modes of the two fans, fin pitches and operating ambient conditions was carried out using the validated model. The modelling results demonstrated that by optimizing fan operating mode, the difference in frost thickness between the windward and leeward sides of the dual-fan outdoor coil can be reduced by up to 77.3 %, the averaged output heating capacity and COP improved by up to 11.1 % and 12.7 %, respectively, and the number of switching operation of the two fans decreased by 55.6 %. Besides, the recommendations for using the dual-fan outdoor coil at different operating modes of the two fans, different fin pitches and operating ambient conditions were also made. The model can be used as a useful tool in helping achieve higher operating efficiency for ASHPs having the novel dual-fan outdoor coil.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Dynamic defrosting characteristics of air source heat pump and effects of outdoor air parameters on defrost cycle performance
    Chen, Yi-guang
    Guo, Xian-min
    APPLIED THERMAL ENGINEERING, 2009, 29 (13) : 2701 - 2707
  • [32] Techno-economic analysis on frosting and defrosting operations of an air source heat pump unit applied in a typical cold city
    Song, Mengjie
    Wang, Kai
    Liu, Shengchun
    Deng, Shiming
    Dai, Baomin
    Sun, Zhili
    ENERGY AND BUILDINGS, 2018, 162 : 65 - 76
  • [33] Study of a helical coil outside heat transfer characteristics for seawater-source heat pump
    Zhang, Xiaoxiao
    Wang, Zhiwei
    Liu, Yanfeng
    Xu, Lanjing
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (02): : 225 - 231
  • [34] Investigation on the performance coupling characteristics between a compound anti-frosting method and air source heat pump system
    Lyu, Ning
    He, Hui
    Liu, Jian
    Liang, Caihua
    Zhang, Xiaosong
    Wang, Feng
    APPLIED THERMAL ENGINEERING, 2023, 235
  • [35] The study of dynamic characteristics on a novel air source heat pump coupled with liquid-storage gas-liquid separator under non frosting and refrigeration conditions
    Wang, Zhihua
    Zhang, Pengfei
    Wang, Fenghao
    Ma, Longxia
    Ma, Zhenjun
    JOURNAL OF BUILDING ENGINEERING, 2024, 84
  • [36] An experimental study on the uneven refrigerant distribution over a vertically installed multi-circuit outdoor coil in an air source heat pump unit during reverse cycle defrosting
    Song, Mengjie
    Wang, Zhihua
    Mao, Ning
    Li, Zhao
    Chen, Ying
    APPLIED THERMAL ENGINEERING, 2015, 91 : 975 - 985
  • [37] AN EXPERIMENTAL STUDY ON PERFORMANCE IMPROVEMENT FOR AN AIR SOURCE HEAT PUMP BY ALTERNATE DEFROSTING OF OUTDOOR HEAT EXCHANGER
    Jung, Hoon
    Hwang, Jungho
    Jeon, Changduk
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2014, 22 (03)
  • [38] Experimental study of solution defrosting characteristics of air source heat pump
    Jiang, Ping
    Zhang, Yu
    Fan, Hongxiu
    Jin, Qi
    Yu, Yanshun
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [39] A modeling study on developing the condensing-frosting performance maps for a variable speed air source heat pump
    Liu, Shengnan
    Bai, Xiaoxia
    Deng, Shiming
    Zhang, Long
    Wei, Minchen
    JOURNAL OF BUILDING ENGINEERING, 2022, 58
  • [40] Performance of an air-source heat pump with multi-circuit outdoor coil for continuous heating during defrosting
    Tang, Lan
    Liu, Xi 'an
    He, Shiquan
    Li, Qingjian
    JOURNAL OF BUILDING ENGINEERING, 2024, 85