A modelling study on the frosting characteristics of a novel dual-fan outdoor coil in an Air Source Heat Pump unit

被引:5
|
作者
Bai, Xiaoxia [1 ]
Liu, Shengnan [1 ]
Deng, Shiming [2 ]
Zhang, Long [3 ]
Wei, Minchen [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Hong Kong, Peoples R China
[2] Qatar Univ, Dept Mech & Ind Engn, POB 2713, Doha, Qatar
[3] Beijing Inst Technol, Sch Mech Engn, Dept Energy & Power Engn, Beijing, Peoples R China
关键词
Air source heat pump; Novel dual -fan outdoor coil; Dynamic mathematical model; Even frosting characteristics; Heating performances; PERFORMANCE; GROWTH; EXCHANGER; FLOW; FIN; TEMPERATURE; PREDICTION; DEFROST;
D O I
10.1016/j.applthermaleng.2022.119933
中图分类号
O414.1 [热力学];
学科分类号
摘要
Uneven frosting along the airflow direction in a traditional outdoor coil in air source heat pumps (ASHPs) was inevitable due to a fixed one-way outdoor airflow direction, causing a rapid deterioration in heating performances of ASHPs. To alleviate this uneven frosting phenomenon, a novel dual-fan outdoor coil where air flow direction can be alternately reversed was proposed in a previous experimental study. To more effectively and comprehensively study the operating characteristics of ASHPs having the dual-fan outdoor coil at different fan operating modes, with different configurations and under different operating ambient conditions, a dynamic mathematical model for the experimental ASHP having the dual-fan outdoor coil was developed and experimentally validated. Then a follow-up modelling study for different operating modes of the two fans, fin pitches and operating ambient conditions was carried out using the validated model. The modelling results demonstrated that by optimizing fan operating mode, the difference in frost thickness between the windward and leeward sides of the dual-fan outdoor coil can be reduced by up to 77.3 %, the averaged output heating capacity and COP improved by up to 11.1 % and 12.7 %, respectively, and the number of switching operation of the two fans decreased by 55.6 %. Besides, the recommendations for using the dual-fan outdoor coil at different operating modes of the two fans, different fin pitches and operating ambient conditions were also made. The model can be used as a useful tool in helping achieve higher operating efficiency for ASHPs having the novel dual-fan outdoor coil.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] An experimental study on achieving even-frosting for an air source heat pump using a novel dual-fan outdoor coil
    Bai, Xiaoxia
    Liu, Shengnan
    Deng, Shiming
    Zhang, Long
    Wei, Minchen
    ENERGY AND BUILDINGS, 2022, 255
  • [2] An experimental study on even frosting performance of an air source heat pump unit with a multi-circuit outdoor coil
    Song Mengjie
    Xia Liang
    Mao Ning
    Deng Shiming
    APPLIED ENERGY, 2016, 164 : 36 - 44
  • [3] An optimal control strategy for ASHP units with a novel dual-fan outdoor coil for evener frosting along airflow direction based on GRNN modelling
    Bai, Xiaoxia
    Liu, Shengnan
    Deng, Shiming
    Zhang, Long
    Wei, Minchen
    ENERGY AND BUILDINGS, 2023, 292
  • [4] An experimental study on defrosting performance of an air source heat pump unit with a multi-circuit outdoor coil at different frosting evenness values
    Song, Mengjie
    Chen, Ailu
    Mao, Ning
    APPLIED THERMAL ENGINEERING, 2016, 94 : 331 - 340
  • [5] An experimental study on the defrosting performances of an ASHP having a novel dual-fan outdoor coil under different levels of frosting evenness along airflow direction
    Bai, Xiaoxia
    Ge, Zhong
    Deng, Shiming
    Qu, Minglu
    Sang, Xuejing
    Zhang, Long
    ENERGY AND BUILDINGS, 2024, 318
  • [6] Effects of face velocity of outdoor heat exchanger on frosting characteristics of air source heat pump system
    Guo, Xianmin
    Wang, Dongli
    Chen, Yiguang
    Wang, Weihua
    Huagong Xuebao/CIESC Journal, 2012, 63 (SUPPL. 2): : 32 - 37
  • [7] Anti-frosting performance of sprayable superhydrophobic coating suitable for outdoor coil of air source heat pump
    Wang, Feng
    Zhou, Yuling
    Yang, Weibo
    Ni, Meiqin
    Zhang, Xiaosong
    Liang, Caihua
    APPLIED THERMAL ENGINEERING, 2020, 169
  • [8] Techno-economic analysis on frosting/defrosting operations for an air source heat pump unit with an optimized multi-circuit outdoor coil
    Song, Mengjie
    Tso, Chiyan
    Chao, Christopher Yuhang
    Wu, Chili
    ENERGY AND BUILDINGS, 2018, 166 : 165 - 177
  • [9] Study on performance of air source heat pump water heater/chiller unit under frosting
    Yao, Y
    Jiang, YQ
    Ma, ZL
    Deng, SM
    ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 1563 - 1567
  • [10] An experimental study on frosting and defrosting performances of a novel air source heat pump unit with a radiant-convective heating terminal
    Zhang, Long
    Dong, Jiankai
    Jiang, Yiqiang
    Deng, Shiming
    Huang, Shun
    ENERGY AND BUILDINGS, 2018, 163 : 10 - 21