A non-invasive method of glucose monitoring using FR4 material based microwave antenna sensor

被引:1
|
作者
Nella, Anveshkumar [1 ]
Aldhaheri, Rabah Wasel [2 ]
Kamili, Jagadeesh Babu [3 ]
Sobahi, Nebras Mohammed [2 ]
机构
[1] VIT Bhopal Univ, Sch EEE, Bhopal 466114, India
[2] King Abdulaziz Univ, Dept Elect & Comp Engn, Jeddah 21589, Saudi Arabia
[3] St Anns Coll Engg & Tech, Dept ECE, Chirala, India
关键词
finger phantom; frequency shift; glucose level (mg/dL) monitoring; non-invasive method; time-domain analysis; Yagi-Uda antenna; DIELECTRIC-PROPERTIES;
D O I
10.1515/secm-2022-0187
中图分类号
TB33 [复合材料];
学科分类号
摘要
This work presents a unique non-invasive method for monitoring glucose levels in blood using a planar Yagi-Uda antenna as a microwave sensor. The proposed antenna, operating at 5.5 GHz, exhibits a directional radiation pattern with a peak gain of 6.74 dBi. A low-cost FR4 material of size 30 mm x 40 mm x 1.6 mm is used as a dielectric substrate. A human finger phantom, comprising layers of skin, fat, blood, and bone, is created at 5.5 GHz in EM simulation tool for mimicking a real human finger. The finger phantom is positioned at different locations around the antenna and corresponding frequency shifts are remarked to a variation in glucose concentration from 0-500 mg/dL. An exemplary frequency shift of maximum 26 MHz is recorded when the phantom is placed at the bottom of the antenna. Time domain analysis is also carried out to understand the effect of glucose concentration variation on the output signal amplitude and delay. Simulated antenna results are found to be in stupendous agreement with the measured results. An experiment of placing a real human finger around the fabricated antenna also presents a splendid correspondence with the simulated results. Hence, this mechanism can be expedient for monitoring glucose levels in blood.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Analysis and Design of a Microwave Coplanar Sensor for Non-Invasive Blood Glucose Measurements
    Cebedio, Maria Celeste
    Rabioglio, Lucas Andres
    Gelosi, Ivan Exequiel
    Ribas, Ramiro Avalos
    Uriz, Alejandro Jose
    Moreira, Jorge Castineira
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (18) : 10572 - 10581
  • [42] Non-invasive monitoring of blood glucose using Raman spectroscopy
    Peterson, CM
    Peterson, KP
    Chaiken, J
    Finney, W
    Knudson, PE
    Weinstock, RS
    [J]. DIABETES, 2000, 49 : A121 - A121
  • [43] Feasibility Evaluation of Metamaterial Microwave Sensors for Non-Invasive Blood Glucose Monitoring
    Malena, Lukas
    Fiser, Ondrej
    Stauffer, Paul R.
    Drizdal, Tomas
    Vrba, Jan
    Vrba, David
    [J]. SENSORS, 2021, 21 (20)
  • [44] Non-Invasive Glucose Monitoring Using Open Electromagnetic Waveguides
    Hofmann, M.
    Bloss, M.
    Weigel, R.
    Fischer, G.
    Kissinger, D.
    [J]. 2012 42ND EUROPEAN MICROWAVE CONFERENCE (EUMC), 2012, : 546 - 549
  • [45] Non-Invasive Blood Glucose Monitoring using a Hybrid Technique
    Nanayakkara, Nuwan D.
    Munasingha, S. C.
    Ruwanpathirana, G. P.
    [J]. 2018 MORATUWA ENGINEERING RESEARCH CONFERENCE (MERCON) 4TH INTERNATIONAL MULTIDISCIPLINARY ENGINEERING RESEARCH CONFERENCE, 2018, : 7 - 12
  • [46] A Survey on Non-Invasive Blood Glucose Monitoring Using NIR
    Menon, K. A. Unnikrishna
    Hemachandran, Deepak
    Abhishek, T. K.
    [J]. 2013 INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND SIGNAL PROCESSING (ICCSP), 2013, : 1069 - 1072
  • [47] Voltage Intensity Based Non-Invasive Blood Glucose Monitoring
    Menon, K. A. Unnikrishna
    Hemachandran, Deepak
    Kunnath, Abishek Thekkeyil
    [J]. 2013 FOURTH INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATIONS AND NETWORKING TECHNOLOGIES (ICCCNT), 2013,
  • [48] Non-invasive impedance based continuous glucose monitoring system
    Talary, M. S.
    Dewarrat, F.
    Huber, D.
    Falco-Jonasson, L.
    Caduff, A.
    [J]. 13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 636 - +
  • [49] Non-invasive Glucose Monitoring Based on Optical Coherent Tomography
    Chen, Tseng-Lin
    Lo, Yu-Lung
    Quoc-Hung Phan
    [J]. BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2018, 10711
  • [50] Research Based on Non-Invasive Blood Glucose Monitoring Equipment
    Zhao, Menglin
    Du, Yuyuan
    Jia, Yuntong
    Liu, Chang
    [J]. 3RD ANNUAL INTERNATIONAL CONFERENCE ON INFORMATION SYSTEM AND ARTIFICIAL INTELLIGENCE (ISAI2018), 2018, 1069