Effectiveness of Optimal Shared Multiple Tuned Mass Damper Inerters for Pounding Mitigation of Adjacent Buildings

被引:11
|
作者
Djerouni, Salah [1 ,2 ]
Elias, Said [3 ]
Abdeddaim, Mahdi [1 ]
De Domenico, Dario [4 ]
机构
[1] Mohamed Khider Univ, Fac Sci & Technol, Dept Civil Engineeringand Hydraul, LARGHYDE Lab, BP 145 RP, Biskra 07000, Algeria
[2] Univ Iceland, Fac Civil & Environm Engn, Earthquake Engn Res Ctr, Sch Engn & Nat Sci, Austurvegur 2a, IS-800 Selfoss, Iceland
[3] Univ Twente UTWENTE, Fac Engn Technol ET, Dept Construct Management & Engn CME, NL-7500 Twente, Netherlands
[4] Univ Messina, Dept Engn, Contrada Di Dio,Villaggio S Agata, I-98166 Messina, Italy
关键词
Adjacent buildings; Pounding risk; Inerter; Tuned mass damper inerter (TMDI); Particle swarm optimization; Tuned inerter damper (TID); Seismic response control; VIBRATION CONTROL; DESIGN; OPTIMIZATION; SYSTEMS;
D O I
10.1061/(ASCE)SC.1943-5576.0000732
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Pounding between adjacent buildings subjected to ground motion excitation is one of the most dangerous phenomena for building safety. In this paper, three novel configurations are proposed (two of them are uncoupled, and one of them is coupled), and two different passive devices are used, namely, tuned mass damper inerter (TMDI) and tuned inerter damper (TID). In addition, the proposed configurations are investigated for pounding mitigation. To determine the devices' optimum parameters (mass, inertance, stiffness, and damping), a particle swarm optimization algorithm is used. The objective function is set to minimize the peak of the frequency response functions of interstory drift. The proposed configurations are compared with the best existing configuration in the literature. A large set of ground motion records is used to illustrate the efficiency of the proposed configurations. Based on the results, it is found that the proposed uncoupled configurations by using TMDIs or TIDs perform better than the existing configuration in the literature.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Vibration Control of a Pipeline Structure Using Pounding Tuned Mass Damper
    Song, G. B.
    Zhang, P.
    Li, L. Y.
    Singla, M.
    Patil, D.
    Li, H. N.
    Mo, Y. L.
    JOURNAL OF ENGINEERING MECHANICS, 2016, 142 (06)
  • [32] Optimum tuned mass damper approaches for adjacent structures
    Nigdeli, Sinan Melih
    Bekdas, Gebrail
    EARTHQUAKES AND STRUCTURES, 2014, 7 (06) : 1071 - 1091
  • [33] POUNDING TUNED MASS DAMPER (PTMD): AN INNOVATIVE DAMPER FOR SUBSEA PIPELINE AND JUMPER VIBRATION CONTROLS
    Patil, Devendra
    Kalia, Akshay
    Song, Gangbing
    Lara, Marcus
    PROCEEDINGS OF THE ASME INDIA INTERNATIONAL OIL AND GAS PIPELINE CONFERENCE, 2017, 2017,
  • [34] Optimal design and seismic performance of Multi-Tuned Mass Damper Inerter (MTMDI) applied to adjacent high-rise buildings
    De Domenico, Dario
    Qiao, Haoshuai
    Wang, Qinhua
    Zhu, Zhiwen
    Marano, Giuseppe
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (14):
  • [35] Closed-form optimal design of the tuned inerter damper (TID) connecting adjacent flexible buildings
    Zhang, Zili
    Li, Xiang
    Chen, Bei
    Hua, Xugang
    ENGINEERING STRUCTURES, 2024, 302
  • [36] Response mitigation performance and energy dissipation enhancement of tuned viscous mass damper applied on adjacent structures
    Hao, Linfei
    He, Hui
    Tan, Ping
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 150
  • [37] Comparative Studies on Nonlinear Structures with Multiple Tuned Mass Damper and Multiple Tuned Impact Damper
    Lu, Zheng
    Zhou, Mengyao
    Ma, Naiyin
    Du, Jiang
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2023, 23 (14)
  • [38] Optimization of Vibration Control of Adjacent Buildings Structures by a New Inertial Amplified Mass-Tuned Damper
    Xiaofang Kang
    Huayang Li
    Xinyue Zhu
    Ao Zhang
    Jianjun Tang
    Xianzeng Shi
    Journal of The Institution of Engineers (India): Series A, 2025, 106 (1) : 241 - 258
  • [39] Experimental study on the vibration control performance of a pounding tuned rotary mass damper
    Li S.-J.
    Sun L.
    Yu H.
    Kong F.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2020, 33 (05): : 861 - 868
  • [40] Mitigation measures for earthquake induced pounding effects on seismic performance of adjacent buildings
    Shehata E. Abdel Raheem
    Bulletin of Earthquake Engineering, 2014, 12 : 1705 - 1724