Cooling of a PVT System Using an Underground Heat Exchanger: An Experimental Study

被引:4
|
作者
Majeed, Saif H. [1 ]
Abdul-Zahra, Amar S. [1 ]
Mutasher, Dheya G. [1 ]
Dhahd, Hayder A. [1 ]
Fayad, Mohammed A. [2 ]
Al-Waeli, Ali H. A. [3 ]
Kazem, Hussein A. [4 ]
Chaichan, Miqdam T. [2 ]
Al-Amiery, Ahmed A. [2 ,5 ]
Isahak, Wan Nor Roslam Wan [5 ]
机构
[1] Univ Technol Iraq, Mech Engn Dept, Baghdad 10001, Iraq
[2] Univ Technol Iraq, Energy & Renewable Energies Technol Ctr, Baghdad 10001, Iraq
[3] Amer Univ Iraq, Engn Dept, Sulaimani 46001, Iraq
[4] Sohar Univ, Fac Engn, Sohar 311, Oman
[5] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Chem & Proc Engn, Bangi 43000, Selangor, Malaysia
来源
ACS OMEGA | 2023年 / 8卷 / 33期
关键词
THERMAL PERFORMANCE; GEOTHERMAL-ENERGY; EXERGY ANALYSIS; WATER; PUMP; ENHANCEMENT; NANOFLUIDS; VISCOSITY; PILE; OMAN;
D O I
10.1021/acsomega.2c07900
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the recent decades,the researchers have been focused on theuse of photovoltaic thermal (PVT) systems that provide the best performanceand cooling for the photovoltaic panels. In this study, a PVT systemconsisting of a monocrystalline PV panel and a spiral heat exchangerwas connected to an underground heat exchanger that is buried at adepth of 4 m below the surface of the earth. The procedure of thecurrent study can be considered the first of its kind in the MiddleEast and North Africa region (based on the researchers' knowledge).The study was carried out on agricultural land in Baghdad-Iraq duringmonths of July and August-2022, which are considered the harshestweather conditions for this city. The heat exchanger consists of acopper tube with a length of 21 m and formed in the shape of 3U, andit was buried in the earth and connected with a PVT system. The resultsof the study showed that the site chosen to bury the heat exchanger(4 m deep) has a stable soil temperature at 22.5 & DEG;C. From variousvolumetric flow rates, a flow rate of 0.18 l/s was selected whichis considered the highest flow rate that can show vibration in thePVT system which may harm the system. The practical measurements showedthat the largest difference in the surface temperatures of standalonePV and PVT was around 20 & DEG;C in favor of the latter. The electricalefficiency of the studied PVT system also increased to outperformthe standalone PV system by 127.3%. By comparing the results of thecurrent study with studies of water-cooled PVT systems from the literature,it is clear that the proposed system is feasible and has an acceptableefficiency in such harsh weather conditions tested during the experiment.
引用
收藏
页码:29926 / 29938
页数:13
相关论文
共 50 条
  • [21] An experimental study on the validation of cooling capability for the Passive Auxiliary Feedwater System (PAFS) condensation heat exchanger
    Kim, Seok
    Bae, Byoung-Uhn
    Cho, Yun-Je
    Park, Yu-Sun
    Kang, Kyoung-Ho
    Yun, Byong-Jo
    NUCLEAR ENGINEERING AND DESIGN, 2013, 260 : 54 - 63
  • [22] Experimental study on the heat transfer at the heat exchanger of the thermoacoustic refrigerating system
    Nsofor, Emmanuel C.
    Celik, Serdar
    Wang, Xudong
    APPLIED THERMAL ENGINEERING, 2007, 27 (14-15) : 2435 - 2442
  • [23] An Experimental Study of Adsorption Cooling System by Using Low Grade Heat Source
    Elgohary, H. M.
    Soliman, H. M.
    Soliman, A. M.
    Gouda, H. H.
    Chowdhury, S. P.
    2018 IEEE PES/IAS POWERAFRICA CONFERENCE, 2018, : 810 - 816
  • [24] Experimental study on an underground thermal energy storage system using borehole heat exchangers
    Di, Bing
    Ma, Chong-Fang
    Zhang, Guang-Yu
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (05): : 813 - 816
  • [25] Experimental study of a rectangular microchannel printed circuit heat exchanger using supercritical carbon dioxide and water cooling
    Ren, Yan
    Jiang, Ruowen
    Wang, Peidong
    Wu, Weidong
    Yang, Yingying
    Yang, Qiguo
    APPLIED THERMAL ENGINEERING, 2025, 262
  • [26] Stratification of Long-term Cooling System Using Condensation Heat Exchanger
    Yang, Jin-Hwa
    Ahn, Tae-Hwan
    Bae, Hwang
    Park, Hyun-Sik
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2022, 46 (03) : 127 - 132
  • [27] The study of heat control on PVT modules with a new leaf-like heat exchanger
    Zhang, Yingbo
    Shen, Chao
    Zhang, Chunxiao
    Lv, Guoquan
    Sun, Cheng
    Chwieduk, Dorota
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2021, 13 (02)
  • [28] An experimental study of a cross-flow type plate heat exchanger for dehumidification/cooling
    Saman, WY
    Alizadeh, S
    SOLAR ENERGY, 2002, 73 (01) : 59 - 71
  • [29] Numerical and experimental study on intermittent spray cooling for plate-fin heat exchanger
    Jin, Qi
    Yu, Yanshun
    Zhang, Jiahui
    APPLIED THERMAL ENGINEERING, 2023, 234
  • [30] An experimental study on the frosting in heat exchanger using a fin bundle
    Koyama, Shigeru
    Kim, Dong Hwi
    Kuwahara, Ken
    Kondou, Chieko
    Oguni, Kensaku
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 117 - +