摘要
In recent years, global climate change caused by excessive CO2 emissions has attracted wide attention. Within this context, CO2 capture by gas-liquid contactor based on membranes is one of the most promising technologies for post-combustion CO2 capture. However, mass transfer deterioration due to membrane wetting becomes one of barriers for its development. In this paper, based on Laplace-Young equation, reliable individual membrane pore wetting model is constructed to demonstrate detailed wetting process inside membrane pores, which is verified by molecular dynamic (MD) numerical simulation. The wetting conditions of ceramic membrane with 1.26 mu m average pore size and 51.4 degrees contact angle are investigated in experiments. The results show that neither average nor maximum pore diameters can accurately predict liquid and bubble breakthrough pressures of ceramic membrane. The actual liquid and bubble breakthrough pressures of ceramic membrane are slightly lower than critical liquid and bubble breakthrough pressures corresponding to the maximum pore size. The wetting state of ceramic membrane can be determined by combining individual pore wetting model and actual membrane pore distribution. In addition, for practical application process of CO2 capture by gas-liquid contactor with ceramic membrane, some suggestions to avoid membrane wetting are proposed for selection of ceramic membrane and system operation perspective. The membrane wetting analysis method proposed in this paper not only contributes to future applications of ceramic membrane in CO2 capture, but is also widely applicable to other gas-liquid contactors in membrane separation process.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Biocatalytic PVDF composite hollow fiber membranes for CO2 removal in gas-liquid membrane contactor
    Xu, Yilin
    Lin, Yuqing
    Chew, Nick Guan Pin
    Malde, Chandresh
    Wang, Rong
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2019, 572 : 532 - 544
  • [22] Effect of PVDF concentration on the morphology and performance of hollow fiber membrane employed as gas-liquid membrane contactor for CO2 absorption
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Duidar, Ali
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 98 : 174 - 185
  • [23] Experimental study on membrane wetting in gas-liquid membrane contacting process for CO2 absorption by single and mixed absorbents
    Rongwong, Wichitpan
    Jiraratananon, Ratana
    Archariyawut, Supakorn
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2009, 69 (01) : 118 - 125
  • [24] A novel gas-liquid contactor for chemisorption of CO2
    Kundu, A.
    Basu, J. K.
    Das, G.
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 94 : 115 - 123
  • [25] Mass Transfer Analysis of CO2 Capture by PVDF Membrane Contactor and Ionic Liquid
    Gomez-Coma, Lucia
    Garea, Aurora
    Irabien, Angel
    [J]. CHEMICAL ENGINEERING & TECHNOLOGY, 2017, 40 (04) : 678 - 690
  • [26] Factors influencing CO2 capture by PVDF membrane contactor
    Lai, Chunfang
    Yang, Bo
    Zhang, Guoliang
    Wen, Caishao
    Cao, Rong
    Wu, Rongrong
    [J]. Huagong Xuebao/CIESC Journal, 2012, 63 (02): : 500 - 507
  • [27] Improved CO2 Absorption in a Gas-Liquid Countercurrent Column Using a Ceramic Foam Contactor
    Wang, Zhen
    Gupta, Mayank
    Warudkar, Sumedh S.
    Cox, Kenneth R.
    Hirasaki, George J.
    Wong, Michael S.
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (05) : 1387 - 1400
  • [28] Study of an innovative gas-liquid contactor for CO2 absorption
    Chabanon, E.
    Bouallou, C.
    Remigy, J. C.
    Lasseuguette, E.
    Medina, Y.
    Favre, E.
    Nguyen, P. T.
    Roizard, D.
    [J]. 10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 1769 - 1776
  • [29] Modeling of CO2 Stripping in a Hollow Fiber Membrane Contactor for CO2 Capture
    Wang, Zhen
    Fang, Mengxiang
    Yu, Hai
    Ma, Qinhui
    Luo, Zhongyang
    [J]. ENERGY & FUELS, 2013, 27 (11) : 6887 - 6898
  • [30] Biogas upgrading by CO2 removal with a highly selective natural amino acid salt in gas-liquid membrane contactor
    Yan, Shuiping
    He, Qingyao
    Zhao, Shuaifei
    Wang, Yuanyuan
    Ai, Ping
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2014, 85 : 125 - 135