A flexible load adaptive control strategy for efficient photovoltaic hydrogen generation system

被引:3
|
作者
Kang, Zhongjian [1 ]
Duan, Fengtong [1 ]
机构
[1] China Univ Petr East China, Coll New Energy, Qingdao, Peoples R China
基金
中国国家自然科学基金;
关键词
Photovoltaic hydrogen generation; Novel topology; Dual active bridge DC/DC converter; Electrical spring; Triple-phase shift modulation; Maximum power point tracking; DUAL-ACTIVE-BRIDGE; PHASE-SHIFT CONTROL; ENERGY-STORAGE; CONVERTER;
D O I
10.1016/j.solener.2023.112150
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The adaptive adjustment of the input current in proton exchange membrane electrolyzers (PEMEL) can provide several benefits, including the enhancement of PEMEL efficiency and the extension of its operating lifespan within an optimal range. This study presents a novel configuration for a photovoltaic (PV) hydrogen generation system that allows for the direct integration of PV. Moreover, the utilization of the triple -phase shift (TPS) modulation technique is implemented in order to achieve maximum power point tracking (MPPT) control within dual active bridge (DAB) DC/DC converters. The proposed strategy offers a pre -control approach for active adjustment of flexible loads to mitigate the mismatch between power output and load caused by fluctuations in renewable energy sources. This mismatch can lead to excessive current ripple, which in turn can impact the safe functioning of the PEMEL. In tandem with the analysis of the factors that contribute to ripple and the properties of the Electrical Spring (ES), relevant multiple variables are selected as control signals for the control strategy. This is done to effectively regulate the magnitude of non -essential loads and consequently reduce the ripple in the PEMEL system. The use of the ES pre -control technique effectively addresses the issue of delayed response of the PEMEL to PV oscillations, which is attributed to the large time-lag characteristics of electrolyzers. The simulation results at steady-state conditions and sudden changes in lighting conditions demonstrate concurrently that the overall control strategy yields a reduction in current stress in the DAB to 30.09% and 51.59%, respectively, enables MPPT in PV systems, and decreases the input current ripple of PEMEL to 80.1% and 57.67%, showing stronger anti -disturbance ability.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Adaptive Fractional order Control of Photovoltaic Power Generation System with Disturbance Observer
    Veisi, Amir
    Delavari, Hadi
    2021 7TH INTERNATIONAL CONFERENCE ON CONTROL, INSTRUMENTATION AND AUTOMATION (ICCIA), 2021, : 58 - 62
  • [22] Control strategy of photovoltaic-energy storage power generation system considering photovoltaic power curtailment
    Wang, Gong
    Zhang, Dong
    Li, Xiangjun
    Cao, Shengxian
    Wang, Chenggang
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (03): : 817 - 824
  • [23] Improved load-adaptive control strategy for PMSG based stand-alone wind energy generation system
    Zeng, Rong
    Nian, Heng
    Quan, Yu
    Liu, Jiao
    2009 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2009, : 1594 - 1599
  • [24] Frequency control strategy for coordinated energy storage system and flexible load in isolated power system
    Yu, Jie
    Liao, Siyang
    Xu, Jian
    ENERGY REPORTS, 2022, 8 : 966 - 979
  • [25] Load Frequency Control in a Hybrid Thermal-Wind-Photovoltaic Power Generation System
    Koley, Indrajit
    Bhowmik, Partha Sarathee
    Datta, Asim
    2017 4TH INTERNATIONAL CONFERENCE ON POWER, CONTROL & EMBEDDED SYSTEMS (ICPCES), 2017,
  • [26] Independent Photovoltaic Hydrogen System and Control
    Zhang, Xing
    Zhu, Qiaohua
    Zhan, Xiangdui
    Chen, Siyu
    Wu, Yuhang
    Wu, Mengze
    2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 409 - 414
  • [27] Adaptive Control Strategy of VSG Parameters in Photovoltaic Microgrid
    Yin G.
    Dong H.
    Dai Y.
    Wang H.
    Wang S.
    Dianwang Jishu/Power System Technology, 2020, 44 (01): : 192 - 199
  • [28] STUDY ON PHOTOVOLTAIC GREEN HYDROGEN PRODUCTION SYSTEM BASED ON ADAPTIVE CONTROL OF HYBRID ELECTROLYZER
    Wang, Shunyan
    Ren, Yongfeng
    Zhang, Xiaolong
    Xue, Yu
    Liu, Peng
    Wen, Guowei
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (07): : 20 - 28
  • [29] Adaptive fuzzy gain scheduling in position control of servo hydraulic system with flexible load
    Yousefi, Hassan
    Handroos, Heikki
    Proceedings of the ASME Fluid Power Systems and Technology Division - 2005, 2005, 12 : 1 - 8
  • [30] Source-Storage-Load Flexible Scheduling Strategy Considering Characteristics Complementary of Hydrogen Storage System and Flexible Carbon Capture System
    Zhao, Lang
    Wang, Zhidong
    Yi, Haiqiong
    Li, Yizheng
    Wang, Xueying
    Xiao, Yunpeng
    Hu, Zhiyun
    Zhou, Honglian
    Zhang, Xinhua
    ENERGIES, 2024, 17 (16)