Ultralocal Model-Free Predictive Control of T-Type Grid-Connected Converters Based on Extended Sliding-Mode Disturbance Observer

被引:12
|
作者
Long, Bo [1 ,2 ,3 ,4 ]
Zhang, Jiahao [1 ,2 ,3 ,4 ]
Shen, Dawei [1 ,2 ,3 ,4 ]
Rodriguez, Jose [5 ]
Guerrero, Josep M. [6 ]
Chong, Kil To [7 ]
机构
[1] UESTC, Sch Mech & Elect Engn, Chengdu 611731, Peoples R China
[2] Univ Elect Sci & Technol China UESTC, Yangtze Delta Reg Inst Huzhou, Huzhou 313001, Peoples R China
[3] Inst Elect & Informat Engn UESTC, Guangzhou 523808, Guangdong, Peoples R China
[4] Shenyang Univ Technol, MOE Key Lab Special Machine & High Voltage Appara, Shenyang 110870, Peoples R China
[5] Univ Andres Bello, Fac Engn, Santiago 8370146, Chile
[6] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
[7] Jeonbuk Natl Univ, Dept Elect & Informat Engn, Jeonju 54896, South Korea
关键词
Neutral-point voltage control; three-level T-type converter; ultralocal model; SYNCHRONOUS MOTOR; PMSM; IDENTIFICATION;
D O I
10.1109/TPEL.2023.3318178
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Athree-level T-type converter interfaced with an LCL filter (LCL-3LT(2)C) has been widely used in low-voltage and high-quality photovoltaic (PV) systems. The control of LCL-3LT(2)C is a multiobjective optimization problem (MOOP), which is suitable to apply model predictive control (MPC). Although theMPC has fast dynamic response, accurate transient control, and easy handling of MOOP problems, its control performance is still highly dependent on the system model used for the control system. If the system parameter mismatch between the plant and the MPC controller occurs, the performance of the control object will degrade. To solve this problem, a novel adaptive ultralocal model-free predictive control for LCL-3LT(2)C is proposed. First, the relationship between the NP voltage and the converter current is analyzed, and a dynamic antidisturbance factor is introduced into the reference of the converter current for NP voltage suppression. Second, to improve the model estimation accuracy, a new ultralocal model is introduced, which decouples the known and unknown terms of the system into the linear known and the nonlinear unknown terms. Finally, an extended sliding-mode disturbance observer is considered to estimate the nonlinear unknown term. The proposed method simplifies the control of NP voltage, converter current, and grid current. Experimental results on the 10-kW laboratory prototype demonstrate its superior performance over existing techniques.
引用
收藏
页码:15494 / 15508
页数:15
相关论文
共 50 条
  • [31] Predictive control of improved T-type inverter grid-connected optimization model in wind power system
    风电系统改进T型逆变器并网优化模型预测控制
    Yang, Guoliang (y99ygl@ysu.edu.cn), 1600, Science Press (41): : 53 - 60
  • [32] A Modified Model Predictive Power Control for Grid-Connected T-Type Inverter with Reduced Computational Complexity
    Van-Quang-Binh Ngo
    Minh-Khai Nguyen
    Tan-Tai Tran
    Choi, Joon-Ho
    Lim, Young-Cheol
    ELECTRONICS, 2019, 8 (02):
  • [33] Extended State Observer-Based Sliding-Mode Control for Floating Interleaved Boost Converters
    Xu, Liangcai
    Huangfu, Yigeng
    Ma, Rui
    Zhuo, Shengrong
    Zhao, Dongdong
    Zhao, Jun
    Gao, Fei
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 5283 - 5289
  • [34] Model Predictive Control of a Grid-Connected Inverter with LCL Filter using Robust Disturbance Observer
    Nam, Nguyen Ngoc
    Choi, Minho
    Lee, Young Il
    IFAC PAPERSONLINE, 2019, 52 (04): : 135 - 140
  • [35] Sliding-Mode and Proportional-Resonant Based Control Strategy for Three-Phase Two-Leg T-Type Grid-Connected Inverters With LCL Filter
    Altin, Necmi
    Ozdemir, Saban
    Komurcugil, Hasan
    Sefaand, Ibrahim
    Biricik, Samet
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 4492 - 4497
  • [36] Model-free fast integral terminal sliding-mode control method based on improved fast terminal sliding-mode observer for PMSM with unknown disturbances
    Zhao, Kaihui
    Liu, Wenchang
    Zhou, Ruirui
    Dai, Wangke
    Wu, Sicheng
    Qiu, Pengqi
    Yin, Yang
    Jia, Ning
    Yi, Jinwu
    Huang, Gang
    ISA TRANSACTIONS, 2023, 143 : 572 - 581
  • [37] Model-Free Predictive H∞ Control for Grid-Connected Solar Power Generation Systems
    Chen, Jianmin
    Yang, Fuwen
    Han, Qing-Long
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2014, 22 (05) : 2039 - 2047
  • [38] Model-Free Predictive Current Control Strategy of Grid-Connected Inverter Based on Double-Vector
    Tao R.
    Zheng Y.
    Fengxiang W.
    Geye L.
    Zhen L.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (14): : 3759 - 3768
  • [39] Robust Model-Free Control of Grid-Connected Converters with Fast Dynamic and High Quality Performance
    Jabbarnejad, Alireza
    Vaez-Zadeh, Sadegh
    Rodriguez, Jose
    2022 13TH POWER ELECTRONICS, DRIVE SYSTEMS, AND TECHNOLOGIES CONFERENCE (PEDSTC), 2022, : 437 - 442
  • [40] Adaptive Second-Order Sliding Mode Control for Grid-Connected NPC Converters With Enhanced Disturbance Rejection
    Shen, Xiaoning
    Liu, Jianxing
    Marquez, Abraham
    Yin, Yunfei
    Leon, Jose, I
    Vazquez, Sergio
    Wu, Ligang
    Franquelo, Leopoldo G.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (01) : 206 - 220