Inter-Session Repeatability of Marker-Less Motion Capture of Treadmill Running Gait

被引:3
|
作者
Moran, Matthew F. [1 ]
Rogler, Isabella C. [1 ]
Wager, Justin C. [1 ]
机构
[1] Sacred Heart Univ, Dept Phys Therapy & Human Movement Sci, Fairfield, CT 06825 USA
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 03期
关键词
kinematics; marker-less; reliability; foot strike detection; ARTIFACT ASSESSMENT; RELIABILITY;
D O I
10.3390/app13031702
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Twenty-one experienced runners completed three treadmill running sessions on different days. Each session consisted of three consecutive 2 min trials at self-selected speeds (RPE = 3, 5, and 7). An eight-camera marker-less motion capture system and instrumented pressure treadmill (TM) collected data over the final similar to 25 s at each speed. Lower extremity joint angles (ankle, knee, and hip) and segmental angles (pelvis and trunk) were computed for each trial with foot contact and toe off being kinematically determined. Spatiotemporal metrics (ground contact time, step length, and cadence) were measured via TM and compared to their kinematically derived counterparts. All spatiotemporal metrics demonstrated excellent agreement (ICCs > 0.98). Both intra-trial and inter-session variability, averaged across the entire running cycle, for all lower extremity joint angles in all planes were low (intra-trial: sagittal = 2.0 degrees, frontal = 1.2 degrees, and transverse = 1.9 degrees; inter-session: sagittal = 1.4 degrees, frontal = 0.8 degrees, and transverse = 1.3 degrees). Discrete measures of lower extremity joint and segmental angles were evaluated for inter-session reliability at foot contact, toe off, and peak value during the stance phase. On average, discrete measures demonstrated good reliability (ICCsagittal = 0.85, ICCfrontal = 0.83, and ICCtransverse = 0.77) with average standard error of measurement < 1 degrees. Marker-less motion capture reliably measured treadmill running kinematics in a group of runners demonstrating heterogenous foot strike patterns (13 rearfoot strike and 8 non-rearfoot strike) across a range of speeds (2.67-4.44 m/s).
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Inter-session agreement and reliability of the Global Gait Asymmetry index in healthy adults
    Cabral, Silvia
    Fernandes, Rita
    Selbie, W. Scott
    Moniz-Pereira, Vera
    Veloso, Antonio P.
    [J]. GAIT & POSTURE, 2017, 51 : 20 - 24
  • [32] Consistency Verification of Marker-Less Gait Assessment System for Stair Walking
    Ogawa, Ami
    Yorozu, Ayanori
    Mita, Akira
    Takahashi, Masaki
    Georgoulas, Christos
    Bock, Thomas
    [J]. BIOINFORMATICS AND BIOMEDICAL ENGINEERING (IWBBIO 2016), 2016, 9656 : 653 - 663
  • [33] Marker-less Tracking for Respiratory Motion Correction in Nuclear Medicine
    Alnowam, Majdi R.
    Lewis, E.
    Guy, M.
    Wells, K.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3118 - 3121
  • [34] Gait parameters in school going children using a marker-less approach
    Gupta, Ishant
    Kalra, Parveen
    Iqbal, Rauf
    [J]. CURRENT SCIENCE, 2016, 111 (10): : 1668 - 1675
  • [35] Marker-less and calibration-less motion correction method for brain PET
    Yuma Iwao
    Go Akamatsu
    Hideaki Tashima
    Miwako Takahashi
    Taiga Yamaya
    [J]. Radiological Physics and Technology, 2022, 15 : 125 - 134
  • [36] Marker-less and calibration-less motion correction method for brain PET
    Iwao, Yuma
    Akamatsu, Go
    Tashima, Hideaki
    Takahashi, Miwako
    Yamaya, Taiga
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (02) : 125 - 134
  • [37] Garment Compensation in Marker-less Motion Tracking for Medical Imaging
    Lindsay, Clifford
    King, Michael A.
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [38] Vision-Based Marker-Less Motion Measurement for Berthing
    Mizuchi, Yoshiaki
    Kawabata, Yuki
    Kim, Youngbok
    Choi, Yongwoon
    [J]. AETA 2016: RECENT ADVANCES IN ELECTRICAL ENGINEERING AND RELATED SCIENCES: THEORY AND APPLICATION, 2017, 415 : 259 - 268
  • [39] Easy Extrinsic Calibration of VR System and Multi-Camera based Marker-less Motion Capture System
    Takahashi, Kosuke
    Mikami, Dan
    Isogawa, Mariko
    Sun, Siqi
    Kusachi, Yoshinori
    [J]. ADJUNCT PROCEEDINGS OF THE 2019 IEEE INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY (ISMAR-ADJUNCT 2019), 2019, : 83 - 88
  • [40] Comfort assessment of running footwear: Does assessment type affect inter-session reliability?
    Lindorfer, Julia
    Kroell, Josef
    Schwameder, Hermann
    [J]. EUROPEAN JOURNAL OF SPORT SCIENCE, 2019, 19 (02) : 177 - 185