3D reconstruction of coronary artery bifurcations from intravascular ultrasound and angiography

被引:0
|
作者
Wu, Wei [1 ]
Oguz, Usama M. [1 ]
Banga, Akshat [1 ]
Zhao, Shijia [1 ]
Thota, Anjani Kumar [1 ]
Gadamidi, Vinay Kumar [1 ]
Vasa, Charu Hasini [1 ]
Harmouch, Khaled M. [1 ]
Naser, Abdallah [1 ]
Tieliwaerdi, Xiarepati [1 ]
Chatzizisis, Yiannis S. [1 ,2 ]
机构
[1] Univ Miami, Ctr Digital Cardiovasc Innovat, Miller Sch Med, Div Cardiovasc Med, Miami, FL 33136 USA
[2] Univ Miami, Univ Miami Hlth Syst, Leonard M Miller Sch Med, Div Cardiovasc Med, 1120 NW 14th St, Suite 1124, Miami, FL 33136 USA
来源
SCIENTIFIC REPORTS | 2023年 / 13卷 / 01期
基金
美国国家卫生研究院;
关键词
CORRECT 3-DIMENSIONAL RECONSTRUCTION; IN-VIVO VALIDATION; SHEAR-STRESS; BIPLANE ANGIOGRAPHY; FUSION; IVUS; STENOSIS; FLOW; WALL;
D O I
10.1038/s41598-023-40257-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Coronary bifurcation lesions represent a challenging anatomical subset, and the understanding of their 3D anatomy and plaque composition appears to play a key role in devising the optimal stenting strategy. This study proposes a new approach for the 3D reconstruction of coronary bifurcations and plaque materials by combining intravascular ultrasound (IVUS) and angiography. Three patient-specific silicone bifurcation models were 3D reconstructed and compared to micro-computed tomography (mu CT) as the gold standard to test the accuracy and reproducibility of the proposed methodology. The clinical feasibility of the method was investigated in three diseased patient-specific bifurcations of varying anatomical complexity. The IVUS-based 3D reconstructed bifurcation models showed high agreement with the mu CT reference models, with r(2) values ranging from 0.88 to 0.99. The methodology successfully 3D reconstructed all the patient bifurcations, including plaque materials, in less than 60 min. Our proposed method is a simple, time-efficient, and user-friendly tool for accurate 3D reconstruction of coronary artery bifurcations. It can provide valuable information about bifurcation anatomy and plaque burden in the clinical setting, assisting in bifurcation stent planning and education.
引用
收藏
页数:25
相关论文
共 50 条
  • [31] A comprehensive method for geometrically correct 3-D reconstruction of coronary arteries by fusion of intravascular ultrasound and biplane angiography
    Wahle, A
    Prause, GPM
    DeJong, SC
    Sonka, M
    COMPUTER-AIDED DIAGNOSIS IN MEDICAL IMAGING, 1999, 1182 : 363 - 368
  • [32] In Vivo Validation of CAAS QCA-3D Coronary Reconstruction Using Fusion of Angiography and Intravascular Ultrasound (ANGUS)
    Schuurbiers, Johan C. H.
    Lopez, Nieves Gonzalo
    Ligthart, Jurgen
    Gijsen, Frank J. H.
    Dijkstra, Jouke
    Serruys, Patrick W.
    Van der Steen, Antonius F.
    Wentzel, Jolanda J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (05) : 620 - 626
  • [33] Towards a geometrically correct 3-D reconstruction of tortuous coronary arteries based on biplane angiography and intravascular ultrasound
    Prause, GPM
    DeJong, SC
    McKay, CR
    Sonka, M
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1997, 13 (06): : 451 - 462
  • [34] In vivo validation of CAAS QCA-3D coronary reconstruction using fusion of angiography and intravascular ultrasound (ANGUS)
    Wentzel, J. J.
    Schuurbiers, J. C. H.
    Lopez, N. Gonzalo
    Gijsen, F. J. H.
    Dijkstra, J.
    Serruys, P. W.
    Van der Steen, A. F. W.
    EUROPEAN HEART JOURNAL, 2008, 29 : 849 - 849
  • [35] Validation study of a novel method for the 3D reconstruction of coronary bifurcations
    Tsompou, Panagiota I.
    Andrikos, Ioannis O.
    Karanasiou, Georgia S.
    Sakellarios, Antonis I.
    Tsigkas, Nikolaos
    Kigka, Vassiliki I.
    Kyriakidis, Savvas
    Michalis, Lampros K.
    Fotiadis, Dimitrios I.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 1576 - 1579
  • [36] Towards a geometrically correct 3-D reconstruction of tortuous coronary arteries based on biplane angiography and intravascular ultrasound
    Guido P.M. Prause
    Steven C. DeJong
    Charles R. McKay
    Milan Sonka
    The International Journal of Cardiac Imaging, 1997, 13 : 451 - 462
  • [37] Geometrically correct 3-D reconstruction of tortuous coronary arteries: Fusion of biplane coronary angiography and intravascular ultrasound pullback imaging
    Prause, G
    DeJong, SC
    McKay, CR
    Sonka, M
    CIRCULATION, 1996, 94 (08) : 1492 - 1492
  • [38] Spatio-temporal localization of intravascular ultrasound data for accurate 3D reconstruction of coronary arteries
    Shekhar, R
    Cothren, RM
    Vince, DG
    Cornhill, JF
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 668 - 669
  • [39] AUTOMATED 3-D PLAQUE QUANTIFICATION FROM CORONARY CT ANGIOGRAPHY: COMPARISON WITH INTRAVASCULAR ULTRASOUND
    Dey, Damini
    Schepis, Tiziano
    Marwan, Mohamed
    Slomka, Piotr J.
    Berman, Daniel S.
    Achenbach, Stephan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [40] Intra-plaque heterogeneity of coronary artery disease: A 3D intravascular ultrasound (IVUS) study
    Box, Lyndon C.
    Angiolillo, Dominick J.
    Box, Lesleigh A.
    Jiang, Julie
    Gilmore, Paul G.
    Guzman, Luis
    Zenni, Martin A.
    Bass, Theodore A.
    Costa, Marco A.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 100M - 100M