Comparison of Three Video Laryngoscopes and Direct Laryngoscopy for Emergency Endotracheal Intubation While Wearing PPE-AGP: A Randomized, Crossover, Simulation Trial

被引:5
|
作者
Kluj, Przemyslaw [1 ]
Fedorczak, Anna [2 ,3 ]
Fedorczak, Michal [1 ]
Gaszynski, Tomasz [1 ]
Kulak, Cezary [4 ]
Wasilewski, Mikolaj [5 ]
Znyk, Mateusz [4 ]
Bartczak, Maria [4 ]
Ratajczyk, Pawel [1 ]
机构
[1] Med Univ Lodz, Dept Anesthesiol & Intens Care, PL-90549 Lodz, Poland
[2] Med Univ Lodz, Dept Pediat Nephrol & Immunol, PL-93338 Lodz, Poland
[3] Polish Mothers Mem Hosp, Res Inst, Dept Endocrinol & Metab Dis, PL-93338 Lodz, Poland
[4] Med Univ Lodz, Med Simulat Ctr, PL-92213 Lodz, Poland
[5] Med Univ Lodz, Clin Anesthesiol & Intens Therapy, PL-92213 Lodz, Poland
关键词
endotracheal intubation; paramedic; direct laryngoscopy; video laryngoscopy; personal protective equipment; HOSPITAL CARDIAC-ARREST; PERSONAL PROTECTIVE EQUIPMENT; AIRWAY MANAGEMENT; TRACHEAL INTUBATION; PHYSICIANS; MACINTOSH; RADIATION; INSERTION; DEVICES;
D O I
10.3390/healthcare11060884
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: The COVID-19 pandemic has necessitated changes in the safety protocols of endotracheal intubation at every level of care. This study aimed to compare the first-pass success rates (FPS) and intubation times (IT) of three video laryngoscopes (VL) and direct laryngoscopy (DL) for simulated COVID-19 patient emergency intubation (EI). Methods: The study was a prospective, randomized, crossover trial. Fifty-three active paramedics performed endotracheal intubation with the I-view(TM) VL, UESCOPE(R) VL, ProVu(R) VL and Macintosh direct laryngoscope (MAC) wearing personal protective equipment for aerosol-generating procedures (PPE-AGP) on a manikin with normal airway conditions. Results: The longest IT was noted when the UESCOPE(R) (29.4 s) and ProVu(R) (27.7 s) VL were used. The median IT for I-view was 17.4 s and for MAC DL 17.9 s. The FPS rates were 88.6%, 81.1%, 83.0% and 84.9%, respectively, for I-view, ProVu(R), UESCOPE(R) and MAC DL. The difficulty of EI attempts showed a statistically significant difference between UESCOPE(R) and ProVu(R). Conclusions: The intubation times performed by paramedics in PPE-AGP using UESCOPE(R) and ProVu(R) were significantly longer than those with the I-view and Macintosh laryngoscopes. The use of VL by prehospital providers in PPE did not result in more effective EI than the use of a Macintosh laryngoscope.
引用
收藏
页数:11
相关论文
共 37 条
  • [31] Direct vs. Video-Laryngoscopy for Intubation by Paramedics of Simulated COVID-19 Patients under Cardiopulmonary Resuscitation: A Randomized Crossover Trial
    Gadek, Leszek
    Szarpak, Lukasz
    Konge, Lars
    Dabrowski, Marek
    Telecka-Gadek, Dominika
    Maslanka, Maciej
    Drela, Wiktoria Laura
    Jachowicz, Marta
    Iskrzycki, Lukasz
    Bialka, Szymon
    Peacock, Frank William
    Smereka, Jacek
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
  • [32] Comparison of the TruView PCD video laryngoscope and macintosh laryngoscope for pediatric tracheal intubation by novice paramedics: a randomized crossover simulation trial
    Łukasz Szarpak
    Łukasz Czyżewski
    Andrzej Kurowski
    Zenon Truszewski
    European Journal of Pediatrics, 2015, 174 : 1325 - 1332
  • [33] Comparison of the TruView PCD video laryngoscope and macintosh laryngoscope for pediatric tracheal intubation by novice paramedics: a randomized crossover simulation trial
    Szarpak, Lukasz
    Czyzewski, Lukasz
    Kurowski, Andrzej
    Truszewski, Zenon
    EUROPEAN JOURNAL OF PEDIATRICS, 2015, 174 (10) : 1325 - 1332
  • [34] Comparison of the VivaSight single lumen endotracheal tube and the Macintosh laryngoscope for emergency intubation by experienced paramedics in a standardized airway manikin with restricted access: a randomized, crossover trial
    Truszewski, Zenon
    Szarpak, Lukasz
    Smereka, Jacek
    Kurowski, Andrzej
    Evrin, Togay
    Czyzewski, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (05): : 929 - 930
  • [35] Hands-Off Time for Endotracheal Intubation during CPR Is Not Altered by the Use of the C-MAC Video-Laryngoscope Compared to Conventional Direct Laryngoscopy. A Randomized Crossover Manikin Study
    Schuerner, Philipp
    Grande, Bastian
    Piegeler, Tobias
    Schlaepfer, Martin
    Saager, Leif
    Hutcherson, Matthew T.
    Spahn, Donat R.
    Ruetzler, Kurt
    PLOS ONE, 2016, 11 (05):
  • [36] Comparison of dental force applied during endotracheal intubation with hyper-angulated and macintosh-type video laryngoscopy blades used by emergency medicine trainees: A randomized cross-over manikin study
    Karabacak, Ali Riza
    Ozturan, Ibrahim Ulas
    Sefoglu, Omer Faruk
    Dogan, Nurettin Ozgur
    Yaka, Elif
    Yilmaz, Serkan
    Pekdemir, Murat
    TURKISH JOURNAL OF EMERGENCY MEDICINE, 2024, 24 (03): : 151 - +
  • [37] Comparison of the C-MAC video laryngoscope size 2 Macintosh blade with size 2 C-MAC D-Blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: A prospective randomized crossover study
    Sinha, Renu
    Ray, Bikash Ranjan
    Sharma, Ankur
    Pandey, Ravinder Kumar
    Punj, Jyotsna
    Darlong, Vanlalnghaka
    Trikha, Anjan
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2019, 35 (04) : 509 - 514