Image-based motion artifact reduction on liver dynamic contrast enhanced MRI

被引:3
|
作者
Wu, Yunan [1 ,2 ]
Liu, Junchi [3 ,4 ]
White, Gregory M. [2 ]
Deng, Jie [2 ,5 ,6 ]
机构
[1] Northwestern Univ, Dept Elect Comp Engn, 633 Clark St, Evanston, IL 60208 USA
[2] Rush Univ Med Ctr, Dept Diagnost Radiol, 1653 W Congress Pkwy,Jelke Ste 181, Chicago, IL 60612 USA
[3] Illinois IIT, Med Imaging Res Ctr, Chicago, IL 60616 USA
[4] Illinois IIT, Dept Elect & Comp Engn, Chicago, IL 60616 USA
[5] UT Southwestern Med Ctr, Dept Radiat Oncol, 2280 Inwood Rd, Dallas, TX 75235 USA
[6] UT Southwestern Med Ctr, Dept Radiat Oncol, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
关键词
Motion artifacts; Liver; Dynamic contrast enhanced MRI; Deep learning; Simulation; Perceptual loss; CLINICAL MRI; PERFORMANCE; FIBROSIS; NETWORK; TIME;
D O I
10.1016/j.ejmp.2022.12.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Liver MRI images often suffer from degraded quality due to ghosting or blurring artifacts caused by patient respiratory or bulk motion. In this study, we developed a two-stage deep learning model to reduce motion artifact on dynamic contrast enhanced (DCE) liver MRIs. The stage-I network utilized a deep residual network with a densely connected multi-resolution block (DRN-DCMB) network to remove most motion artifacts. The stage-II network applied the generative adversarial network (GAN) and perceptual loss compensation to preserve image structural features. The stage-I network served as the generator of GAN and its pretrained parameters in stage-I were further updated via backpropagation during stage-II training. The stage-I network was trained using small image patches with simulated motion artifacts including image-space rotational and translational motion, and K-space based centric and interleaved linear motion, sinusoidal, and rotational motion to mimic liver motion patterns. The stage-II network training used full-size images with the same types of simulated motion. The liver DCE-MRI image volumes without obvious motion artifacts in 10 patients were used for the training process, of which 1020 images of 8 patients were used for training and 240 images of 2 patients for validation. Finally, the whole two-stage deep learning model was tested with simulated motion images (312 clean images from 5 test patients) and patient images with real motion artifacts (28 motion images from 12 patients). The resulted images after two-stage processing demonstrated reduced motion artifacts while preserved anatomic details without image blurriness, with SSIM of 0.935 +/- 0.092, MSE of 60.7 +/- 9.0 x 10-3, and PSNR of 32.054 +/- 2.219.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Image-based motion artifact reduction on liver dynamic contrast enhanced MRI
    Yu, Zhichao
    Lin, Qianyun
    Gong, Hexiang
    Li, Meijin
    Tang, Dianping
    BIOSENSORS & BIOELECTRONICS, 2023, 223
  • [2] Motion correction of dynamic contrast enhanced MRI of the liver
    Jansen, Marielle J. A.
    Veldhuis, Wouter B.
    van Leeuwen, Maarten S.
    Pluim, Josien P. W.
    MEDICAL IMAGING 2017: IMAGE PROCESSING, 2017, 10133
  • [3] Motion Artifact Reduction Using a Convolutional Neural Network for Dynamic Contrast Enhanced MR Imaging of the Liver
    Tamada, Daiki
    Kromrey, Marie-Luise
    Ichikawa, Shintaro
    Onishi, Hiroshi
    Motosugi, Utaroh
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (01) : 64 - 76
  • [4] Prostate Cancer Detection Using Image-Based Features in Dynamic Contrast Enhanced MRI
    Wang, Liping
    Zheng, Yuanjie
    Rampun, Andrik
    Zwiggelaar, Reyer
    MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2021), 2021, 12722 : 43 - 55
  • [5] Evaluation of motion correction for clinical dynamic contrast enhanced MRI of the liver
    Jansen, M. J. A.
    Kuijf, H. J.
    Veldhuis, W. B.
    Wessels, F. J.
    van Leeuwen, M. S.
    Pluim, J. P. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (19): : 7556 - 7568
  • [6] Motion Compensation in Dynamic Contrast Enhanced MRI
    Liu, W.
    Sung, K.
    Ruan, D.
    MEDICAL PHYSICS, 2014, 41 (06) : 100 - 100
  • [7] Image-based metal artifact reduction in CT images
    Serifovic-Trbalic, A.
    Trbalic, A.
    2016 39TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2016, : 442 - 446
  • [8] Reference Image Compressed Sensing Based Dynamic Contrast Enhanced MRI
    Wang, H.
    Zhou, K.
    Yu, Y.
    He, Q.
    Bao, S.
    Hu, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [9] Model Image-Based Metal Artifact Reduction for Computed Tomography
    Luzhbin, Dmytro
    Wu, Jay
    JOURNAL OF DIGITAL IMAGING, 2020, 33 (01) : 71 - 82
  • [10] Model Image-Based Metal Artifact Reduction for Computed Tomography
    Dmytro Luzhbin
    Jay Wu
    Journal of Digital Imaging, 2020, 33 : 71 - 82