Identifying and Removing Interference and Artifacts in Multifractal Signals With Application to EEG Signals

被引:0
|
作者
Hbibi, Bechir [1 ,2 ,3 ]
Khiari, Cyrine [1 ]
Wirsing, Karlton [3 ]
Mili, Lamine [3 ]
Baccar, Kamel [2 ]
Mami, Abdelkader [1 ]
机构
[1] Univ Tunis El Manar, Fac Sci Tunis, Applicat Lab Energy Efficiency & Renewable Energie, Tunis 1068, Tunisia
[2] Natl Inst Neurol, Intens Care & Anesthesia Dept, Tunis 1007, Tunisia
[3] Virginia Polytech Inst & State Univ, Dept Elect & Comp Engn, Falls Church, VA 22043 USA
关键词
Electroencephalogram signals; artifacts; interference; independent component analysis; projection statistics; multifractal analysis; EEGlab toolbox; INDEPENDENT COMPONENT ANALYSIS; 2-SCALE DIFFERENCE-EQUATIONS; WAVELET TRANSFORM; LOCALIZATION; REGULARITY; BOOTSTRAP; ICA;
D O I
10.1109/ACCESS.2023.3325786
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Recorded Electroencephalogram (EEG) signals are typically affected by interference and artifacts, which can both impact eye reading and computer analysis of the data. Artifacts are induced by physiological (noncerebral) activities of the patient, such as muscular activities of the eyes, or the heart, or the body, while interference may be of external or internal origin. External interference can be induced by electrical machines if the latter are in the same room as the patients, while internal interference can be caused by abnormal breathing, or body movement, or electrode malfunction, or headset movements. Interference may cause severe distortion of EEG signals, resulting in loss of some segments of brain signals, while artifacts are additive signals to brain signals. Therefore, in order to analyze the brain activity signals of a patient, we need to identify and eliminate interference and isolate artifacts. In this paper, we analyze the EEG signals that were recorded using a headset with fourteen channels placed on the heads of comatose patients at the National Institute of Neurology in Tunis, Tunisia. We identify the interference using a robust statistical method known as projection statistics and we separate the brain signals from the artifacts cited above by applying an independent component analysis method. Finally, we show the multifractal behavior of the EEG signals without interference by applying the wavelet leader method and analyze their properties using the singularity spectrum.
引用
收藏
页码:119090 / 119105
页数:16
相关论文
共 50 条
  • [41] INVESTIGATION AND COMPARISON OF SOME MODELS FOR REMOVING OCULAR ARTIFACTS FROM EEG SIGNALS .2. QUANTITATIVE AND PICTORIAL COMPARISON OF MODELS
    IFEACHOR, EC
    JERVIS, BW
    ALLEN, EM
    MORRIS, EL
    WRIGHT, DE
    HUDSON, NR
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (06) : 591 - 598
  • [42] The periodic moving average filter for removing motion artifacts from PPG signals
    Lee, Han-Wook
    Lee, Ju-Won
    Jung, Won-Geun
    Lee, Gun-Ki
    INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2007, 5 (06) : 701 - 706
  • [43] The periodic moving average filter for removing motion artifacts from PPG signals
    Department of Electronic Engineering, Gyeongsang National University, 900 Gajwa-dong, Jinju-si, Kyungnam 660-701, Korea, Republic of
    不详
    Int. J. Control Autom. Syst., 2007, 6 (701-706):
  • [44] Artifacts Removal of EEG Signals using Adaptive Principal Component Analysis
    Turnip, Arjon
    Kusumandari, Dwi Esti
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON COMPUTATION FOR SCIENCE AND TECHNOLOGY, 2015, 5 : 172 - 175
  • [45] Deep learning denoising for EOG artifacts removal from EEG signals
    Mashhadi, Najmeh
    Khuzani, Abolfazl Zargari
    Heidari, Morteza
    Khaledyan, Donya
    2020 IEEE GLOBAL HUMANITARIAN TECHNOLOGY CONFERENCE (GHTC), 2020,
  • [46] Evaluation Criteria of Biological Artifacts Removal Rate from EEG Signals
    Jafarifarmand, Aysa
    Badamchizadeh, Mohammad Ali
    Seyedarabi, Hadi
    2014 IEEE 23RD INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2014, : 123 - 128
  • [47] Removal of Eye Blink Artifacts From EEG Signals Using Sparsity
    Sreeja, S. R.
    Sahay, Rajiv Ranjan
    Samanta, Debasis
    Mitra, Pabitra
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (05) : 1362 - 1372
  • [48] Automatic Detection and Correction of Blink Artifacts in Single Channel EEG Signals
    Rao, G. Bhaskar N.
    Sankar, Anumala Vijay
    Pani, Peri Pinak
    Sidhireddy, Aneesh
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2020, 11 (01) : 349 - 353
  • [49] Multiclass Common Spatial Pattern with Artifacts Removal Methodology for EEG Signals
    Meisheri, Hardik
    Ramrao, Nagaraj
    Mitra, Suman K.
    2016 4TH INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL AND BUSINESS INTELLIGENCE (ISCBI), 2016, : 90 - 93
  • [50] Fractal Feature Based Detection of Muscular and Ocular Artifacts in EEG Signals
    Paulraj, M. P.
    Bin Yaccob, Sazali
    Yogesh, C. K.
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 916 - 921