Ionic liquid-based dispersive liquid-liquid microextraction of succinic acid from aqueous streams: COSMO-RS screening and experimental verification

被引:8
|
作者
Khan, Huma Warsi [1 ]
Zailan, Anis Aina [1 ]
Reddy, Ambavaram Vijaya Bhaskar [2 ]
Goto, Masahiro [3 ]
Moniruzzaman, Muhammad [1 ,4 ,5 ,6 ]
机构
[1] Univ Teknol PETRONAS, Dept Chem Engn, Seri Iskandar, Perak, Malaysia
[2] Atria Inst Technol, Dept Chem, Bengaluru, India
[3] Kyushu Univ, Grad Sch Engn, Dept Appl Chem, Fukuoka, Japan
[4] Univ Teknol PETRONAS, Ctr Res Ion Liquids CORIL, Seri Iskandar, Perak, Malaysia
[5] Univ Teknol PETRONAS, Dept Chem Engn, Seri Iskandar 32610, Perak, Malaysia
[6] Univ Teknol PETRONAS, Ctr Res Ion Liquids CORIL, Seri Iskandar 32610, Perak, Malaysia
关键词
COSMO-RS; succinic acid; microextraction; dispersion; ionic liquids; EXTRACTION;
D O I
10.1080/09593330.2023.2234669
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the present investigation, a total of 108 combinations of ionic liquids (ILs) were screened using the conductor-like screening model for real solvents (COSMO-RS) with the aid of six cations and eighteen anions for the extraction of succinic acid (SA) from aqueous streams through dispersive liquid-liquid microextraction (DLLME). Using the screened ILs, an ionic liquid-based DLLME (IL-DLLME) was developed to extract SA and the role of different reaction parameters in the effectiveness of IL-DLLME approach was investigated. COSMO-RS results suggested that, quaternary ammonium and choline cations form effective IL combinations with [OH over bar ], [F over bar ], and [SO42 over bar ] anions due to hydrogen bonding. In view of these results, one of the screened ILs, tetramethylammonium hydroxide [TMAm][OH] was chosen as the extractant in IL-DLLME process and acetonitrile was adopted as the dispersive solvent. The highest SA removal efficiency of 97.8% was achieved using 25 & mu;L of IL [TMAm][OH] as a carrier and 500 & mu;L of acetonitrile as dispersive solvent. The highest amount of SA was extracted with a stir time of 20 min at 300 rpm, followed by centrifugation for 5 min at 4500 rpm. Overall, the findings showed that IL-DLLME is efficient in extracting succinic acid from aqueous environments while adhering to the first-order kinetics.
引用
收藏
页码:3828 / 3839
页数:12
相关论文
共 50 条
  • [21] Ionic liquid-based vortex-assisted dispersive liquid-liquid microextraction of organophosphorus pesticides in apple and pear
    Zhang, Lijin
    Chen, Fang
    Liu, Shaowen
    Chen, Biyu
    Pan, Canping
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (18) : 2514 - 2519
  • [22] Development of an ionic liquid-based dispersive liquid-liquid microextraction method for the determination of nifurtimox and benznidazole in human plasma
    Padro, J. M.
    Marson, M. E.
    Mastrantonio, G. E.
    Altcheh, J.
    Garcia-Bournissen, F.
    Reta, M.
    TALANTA, 2013, 107 : 95 - 102
  • [23] Selective determination of metal chlorocomplexes in saline waters by magnetic ionic liquid-based dispersive liquid-liquid microextraction
    Herce-Sesa, Belen
    Lopez-Lopez, Jose A.
    Moreno, Carlos
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (07) : 1369 - 1379
  • [24] Robust Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Method for Determination of Chromium(VI) in Saline Solutions
    Taziki, Mohsen
    Shemirani, Farzaneh
    Majidi, Behrooz
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2013, 44 (22) : 3400 - 3411
  • [25] Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Coupled with Capillary Electrophoresis to Determine Drugs of Abuse in Urine
    Liu Xin
    Fu Rao
    Li Min
    Guo Li-Ping
    Yang Li
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (12) : 1919 - 1922
  • [26] [Tf2N]-based ionic liquids for the selective liquid-liquid extraction of levulinic acid/formic acid: COSMO-RS screening and ternary LLE experimental data
    Araya-Lopez, Claudio
    Contreras, Javier
    Merlet, Gaston
    Cabezas, Rene
    Olea, Felipe
    Villarroel, Eduardo
    Salazar, Ricardo
    Romero, Julio
    Quijada-Maldonado, Esteban
    FLUID PHASE EQUILIBRIA, 2022, 561
  • [27] Application of response surface methodology for optimization of ionic liquid-based dispersive liquid-liquid microextraction of cadmium from water samples
    Rajabi, M.
    Kamalabadi, M.
    Jamali, M. R.
    Zolgharnein, J.
    Asanjarani, N.
    HUMAN & EXPERIMENTAL TOXICOLOGY, 2013, 32 (06) : 620 - 631
  • [28] Review of Recent Aromatic-Aliphatic-Ionic Liquid Ternary Liquid-Liquid Equilibria and Their Modeling by COSMO-RS
    Lyu, Yuanyuan
    Brennecke, Joan F.
    Stadtherr, Mark A.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (19) : 8871 - 8893
  • [29] Vortex assisted dispersive liquid-liquid microextraction based on low transition temperature mixture solvent for the HPLC determination of pyrethroids in water samples: Experimental study and COSMO-RS
    Hussin, Siti Amira Mat
    Varanusupakul, Pakorn
    Kassim, Mohd Azlan
    Rozi, Siti Khalijah Mahmad
    Mohamad, Sharifah
    MICROCHEMICAL JOURNAL, 2021, 171
  • [30] A gadolinium-based magnetic ionic liquid for dispersive liquid-liquid microextraction
    Abdelaziz, Mohamed A.
    Mansour, Fotouh R.
    Danielson, Neil D.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (01) : 205 - 214