Long-term performances and membrane lifespan of full-scale MBR treating filtrate from sludge ultra-dewatering

被引:5
|
作者
Mailler, R. [1 ]
Pouillaude, J. [1 ]
Fayolle, Y. [2 ]
Oliveira Filho, M. [1 ,3 ]
Causserand, C. [3 ]
Rocher, V. [1 ]
机构
[1] SIAAP Direct Innovat, Serv Publ Iassainissement Francilien, 82 Ave Kleber, F-92700 Colombes, France
[2] Univ Paris Saclay, INRAE, UR PROSE, Antony, France
[3] Univ Toulouse, CNRS, Lab Genie Chim, INPT,UPS, Toulouse, France
关键词
Sidestream effluent; full-scale MBR; biological treatment; membrane lifespan; wastewater resource recovery facility; WASTE-WATER TREATMENT; HOLLOW-FIBER; BIOREACTORS; TECHNOLOGIES; EXPERIENCES; IMPACT; PVDF;
D O I
10.1080/09593330.2021.2010809
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An MBR treating filtrate from sludge ultra-dewatering (FSD) was studied to evaluate the real applicability to concentrated effluents. The MBR operation is comparable to conventional wastewater MBRs in terms of F/M and nitrogen to sludge ratios, SRT and MLSS in biological tanks. On the contrary, the volume treated is lower with a comparable pollution load, the effluent being concentrated in nitrogen and carbon. Very high and stable ammonium (97.7 +/- 2.4%), total phosphorus (81.8 +/- 11.9%), chemical (89.5 +/- 2.3%) and biochemical oxygen demands (98.8 +/- 0.7%) removals are observed despite a significant modification of the FSD composition. The MBR removal performances are whether comparable or greater than those reported at full-scale for Sharon or Anammox processes. The evolution of membranes properties, in particular, the decrease of permeability induced by the irreversible fouling, leads to a decrease of the daily permeate volume produced and an increase of the chemical cleaning need. The membrane lifespan was determined to be 5.5 years based on both the permeability loss and TSS in permeate. The permeability is directly correlated to the cumulated filtered flux of colloidal matter and a total of 350 kg O-2/m(2) of the membrane (COD in the supernatant) is needed to reach a permeability below 100 LMH/bar. The specific energy consumption is comparable to other wastewater MBRs in kWh/kgCOD removed but the intensive chemical cleanings need to be 2.5-4.5 times more frequent. Overall, it can be concluded that MBR is adapted to treat FSD efficiently.
引用
收藏
页码:1653 / 1666
页数:14
相关论文
共 50 条
  • [21] Long-term assessment of nitrification in a full-scale wastewater treatment plant
    Mertoglu, Bulent
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2008, 43 (05): : 538 - 546
  • [22] Long-term intermittent operation of a full-scale BWRO desalination plant
    Ruiz-Garcia, A.
    Nuez, I
    DESALINATION, 2020, 489
  • [23] Long-term assessment of nitrification in a full-scale wastewater treatment plant
    Mertoglu, Bulent
    Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, 2008, 43 (05): : 538 - 546
  • [24] Long-term operation of ultrafiltration membrane in full-scale drinking water treatment plants in China: Characteristics of membrane performance
    Chang, Haiqing
    Zhu, Yingyuan
    Yu, Haikuan
    Qu, Fangshu
    Zhou, Zhiwei
    Li, Xing
    Yang, Yanling
    Tang, Xiaobin
    Liang, Heng
    DESALINATION, 2022, 543
  • [25] Long-term microbial community dynamics at two full-scale biotrickling filters treating pig house exhaust air
    Van der Heyden, Caroline
    De Mulder, Thijs
    Volcke, Eveline I. P.
    Demeyer, Peter
    Heyndrickx, Marc
    Rasschaert, Geertui
    MICROBIAL BIOTECHNOLOGY, 2019, 12 (04): : 775 - 786
  • [26] Assessing the state of the Bratsk concrete dam from the results of long-term full-scale observations
    Durcheva, V.N.
    Puchkova, S.M.
    Gidrotekhnicheskoe Stroitel'stvo, 1993, (11): : 35 - 40
  • [27] Lessons learnt from long-term leaching experiments of full-scale cemented waste forms
    Kienzler, B
    Vejmelka, P
    Herbert, HJ
    Meyer, H
    Altenhein-Haese, C
    ANNUAL MEETING ON NUCLEAR TECHNOLOGY '99, PROCEEDINGS, 1998, : 351 - 354
  • [28] Long-term operation assessment of a full-scale membrane-aerated biofilm reactor under Nordic conditions
    Uri-Carreno, Nerea
    Nielsen, Per H.
    Gernaey, Krist V.
    Flores-Alsina, Xavier
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 779
  • [29] Assessing the abundance of fungal populations in a full-scale membrane bioreactor (MBR) treating urban wastewater by using quantitative PCR (qPCR)
    Maza-Marquez, P.
    Vilchez-Vargas, R.
    Gonzalez-Martinez, A.
    Gonzalez-Lopez, J.
    Rodelas, B.
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2018, 223 : 1 - 8
  • [30] Long-term full-scale measurements of wind induced vibrations of steel stacks
    Ruscheweyh Consult GmbH, Teichstrasse 8, D-52072 Aachen, Germany
    不详
    不详
    J. Wind Eng. Ind. Aerodyn., (777-783):