Significant changes in lower limb alignment due to flexion and rotation-a systematic 3D simulation of radiographic measurements

被引:16
|
作者
Brunner, Josef [1 ]
Joergens, Maximilian [1 ]
Weigert, Maximilian [2 ]
Kuempel, Hannah [2 ]
Degen, Nikolaus [1 ]
Fuermetz, Julian [1 ,3 ]
机构
[1] Univ Hosp, Musculoskeletal Univ Ctr Munich MUM, Dept Orthopaed & Trauma Surg, LMU, Marchioninistr 15, D-81377 Munich, Germany
[2] LMU, Stat Consulting Unit StaBLab, Munich, Germany
[3] BG Unfallklin Murnau, Dept Trauma Surg, Murnau, Germany
关键词
3D simulation; Radiographic measurement; Coronal alignment; Lower limb rotation; Knee flexion; TOTAL KNEE ARTHROPLASTY;
D O I
10.1007/s00167-022-07302-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Many radiographic lower limb alignment measurements are dependent on patients' position, which makes a standardised image acquisition of long-leg radiographs (LLRs) essential for valid measurements. The purpose of this study was to investigate the influence of rotation and flexion of the lower limb on common radiological alignment parameters using three-dimensional (3D) simulation. Methods Joint angles and alignment parameters of 3D lower limb bone models (n = 60), generated from computed tomography (CT) scans, were assessed and projected into the coronal plane to mimic radiographic imaging. Bone models were subsequently rotated around the longitudinal mechanical axis up to 15 degrees inward/outward and additionally flexed along the femoral intercondylar axis up to 30 degrees. This resulted in 28 combinations of rotation and flexion for each leg. The results were statistically analysed on a descriptive level and using a linear mixed effects model. Results A total of 1680 simulations were performed. Mechanical axis deviation (MAD) revealed a medial deviation with increasing internal rotation and a lateral deviation with increasing external rotation. This effect increased significantly (p < 0.05) with combined flexion up to 30 degrees flexion (- 25.4 mm to 25.2 mm). With the knee extended, the mean deviation of hip-knee-ankle angle (HKA) was small over all rotational steps but increased toward more varus/valgus when combined with flexion (8.4 degrees to - 8.5 degrees). Rotation alone changed the medial proximal tibial angle (MPTA) and the mechanical lateral distal femoral angle (mLDFA) in opposite directions, and the effects increased significantly (p < 0.05) when flexion was present. Conclusions Axial rotation and flexion of the 3D lower limb has a huge impact on the projected two-dimensional alignment measurements in the coronal plane. The observed effects were small for isolated rotation or flexion, but became pronounced and clinically relevant when there was a combination of both. This must be considered when evaluating X-ray images. Extension deficits of the knee make LLR prone to error and this calls into question direct postoperative alignment controls.
引用
收藏
页码:1483 / 1490
页数:8
相关论文
共 29 条
  • [21] Reliability and concurrent validity of angle measurements in lower limb: EOS 3D goniometer versus 2D manual goniometer
    Huang, Jun
    Tian, Fanli
    Zhang, Zhigang
    Shi, Weidong
    Lin, Jun
    Chen, Liang
    Yang, Huilin
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 24 : 96 - 102
  • [22] Digital Volumetric Measurements Based on 3D Scans of the Lower Limb: A Valid and Reproducible Method for Evaluation in Lymphedema Therapy
    Schiltz, Daniel
    Diesch, Sophia Theresa
    Kiermeier, Natalie
    Eibl, Dominik
    Felmerer, Gunther
    Schreml, Stephan
    Biermann, Niklas
    Prantl, Lukas
    Taeger, Christian D.
    ANNALS OF VASCULAR SURGERY, 2024, 105 : 209 - 217
  • [23] Femoral neck version in the spinopelvic and lower limb 3D alignment: a full-body EOS® study in 400 healthy subjects
    Khalife, Marc
    Vergari, Claudio
    Rebeyrat, Guillaume
    Ferrero, Emmanuelle
    Guigui, Pierre
    Assi, Ayman
    Skalli, Wafa
    EUROPEAN SPINE JOURNAL, 2024, 33 (05) : 1807 - 1815
  • [24] Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays
    Chaibi, Y.
    Cresson, T.
    Aubert, B.
    Hausselle, J.
    Neyret, P.
    Hauger, O.
    de Guise, J. A.
    Skalli, W.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (05) : 457 - 466
  • [25] Assessment of two-dimensional (2D) and three-dimensional (3D) lower limb measurements in adults: Comparison of micro-dose and low-dose biplanar radiographs
    Rosskopf, Andrea B.
    Pfirrmann, Christian W. A.
    Buck, Florian M.
    EUROPEAN RADIOLOGY, 2016, 26 (09) : 3054 - 3062
  • [26] Assessment of two-dimensional (2D) and three-dimensional (3D) lower limb measurements in adults: Comparison of micro-dose and low-dose biplanar radiographs
    Andrea B. Rosskopf
    Christian W. A. Pfirrmann
    Florian M. Buck
    European Radiology, 2016, 26 : 3054 - 3062
  • [27] Substrate potential shift due to parasitic minority carrier injection in smart-power ICs:: measurements and full-chip 3D device simulation
    Schenkel, M
    Pfäffli, P
    Wilkening, W
    Aemmer, D
    Fichtner, W
    MICROELECTRONICS RELIABILITY, 2001, 41 (06) : 815 - 822
  • [28] Postseismic Coulomb stress changes on intra-continental dip-slip faults due to viscoelastic relaxation in the lower crust and lithospheric mantle: insights from 3D finite-element modelling
    Meike Bagge
    Andrea Hampel
    International Journal of Earth Sciences, 2017, 106 : 2895 - 2914
  • [29] Postseismic Coulomb stress changes on intra-continental dip-slip faults due to viscoelastic relaxation in the lower crust and lithospheric mantle: insights from 3D finite-element modelling
    Bagge, Meike
    Hampel, Andrea
    INTERNATIONAL JOURNAL OF EARTH SCIENCES, 2017, 106 (08) : 2895 - 2914