Quantitative analysis for sweat-absorbing times of paper-based microfluidic chips

被引:0
|
作者
Huang, Heyue [1 ,2 ,3 ]
Xu, Chuanpei [1 ,3 ]
Long, Peng [4 ,5 ]
Chen, Yanzhang [1 ,3 ]
Huang, Xijun [1 ,3 ]
Liu, Zheng [2 ]
Yang, Hong [1 ,3 ]
机构
[1] Guilin Univ Elect Technol, Sch Elect Engn & Automat, Guilin 541004, Guangxi, Peoples R China
[2] Guilin Univ Aerosp Technol, Sch Elect Informat & Automat, Guilin 541004, Guangxi, Peoples R China
[3] Guangxi Key Lab Automat Detecting Technol & Instru, Guilin 541004, Guangxi, Peoples R China
[4] Cent South Univ, Sch Energy Sci & Engn, Changsha 410083, Hunan, Peoples R China
[5] Guilin Univ Aerosp Technol, Sch Energy & Bldg Environm, Guilin 541004, Guangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
The structure of paper-based microfluidic chips; Sweat-absorbing time; Richards' equation; H value; Finite element analysis; ELECTROCHEMICAL DETECTION; GLUCOSE; DEVICES;
D O I
10.1007/s10404-023-02696-7
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Structures of paper-based microfluidic chips affect the sweat- absorbing time when they are used for sweat analysis. For the first time, we use COMSOL to establish two types of paper-based chip sweat-absorbing models that can quantitatively analyze this phenomenon. The standard model contains 1089 sweat glands, and the simplified model simplifies it according to the idea of finite element division, including 81 sweat glands. Sweat flows in from the bottom of the paper-based chip and out from the electrode contact surface (the upper surface of the central cylinder of the paper-based chip). Both models contain six paper-based chip structures, use Richards' equation as the governing equation, set the outflow velocity to 0, and set the sweating rate of a sweat gland at 0.6 mu L/min. In the standard model, it takes only 46 s for the paper-based structure with the fastest sweat-absorbing speed to completely saturate the electrode contact surface with sweat (meaning the sweat-absorbing time is 46 s), which is 13.06% shorter than that of the slowest structure. In the simplified model, the top 3 structures of sweat-absorbing speed are consistent with the standard model. The simulation results show that the sweat-absorbing time is positively correlated with the H value of the bottom surface of the paper-based structure (defined as the area of the bottom surface /the area of sweat glands covered by the bottom surface), which can be proved by analytical and experimental methods. The analytical method proves that this conclusion can be generalized to other sweating rate conditions.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Electrochemical paper-based microfluidic devices
    Adkins, Jaclyn
    Boehle, Katherine
    Henry, Charles
    ELECTROPHORESIS, 2015, 36 (16) : 1811 - 1824
  • [32] One-Step Hot Microembossing for Fabrication of Paper-Based Microfluidic Chips in 10 Seconds
    Juang, Yi-Je
    Wang, Yu
    Hsu, Shu-Kai
    POLYMERS, 2020, 12 (11) : 1 - 10
  • [33] Paper-based diagnostic chips for viral detection
    Oruganti, Srividya
    Gundimeda, Sai Lakshmi
    Buddolla, Viswanath
    Lakshmi, Buddolla Anantha
    Kim, Young-Joon
    CLINICA CHIMICA ACTA, 2023, 546
  • [34] Capillary flow velocity profile analysis on paper-based microfluidic chips for screening oil types using machine learning
    Chung, Soo
    Loh, Andrew
    Jennings, Christian M.
    Sosnowski, Katelyn
    Ha, Sung Yong
    Yim, Un Hyuk
    Yoon, Jeong-Yeol
    JOURNAL OF HAZARDOUS MATERIALS, 2023, 447
  • [35] Strategies for running multiple quantitative assays simultaneously in paper-based microfluidic devices
    Phillips, Scott T.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242
  • [36] Quantitative evaluation of analyte transport on microfluidic paper-based analytical devices (μPADs)
    Ota, Riki
    Yamada, Kentaro
    Suzuki, Koji
    Citterio, Daniel
    ANALYST, 2018, 143 (03) : 643 - 653
  • [37] Paper-based microfluidic chips for wide time range fluid control based on knife crafting and laser cutting
    Zhong, Songyi
    Xue, Liqian
    Wang, Yue
    Zhang, Changqing
    Liu, Na
    Li, Long
    Zhang, Quan
    Yue, Tao
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 415
  • [38] Fluidic "Timers" for paper-based microfluidic devices
    Phillips, Scott T.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [39] Paper-Based Microfluidic Devices by Plasma Treatment
    Li, Xu
    Tian, Junfei
    Nguyen, Thanh
    Shen, Wei
    ANALYTICAL CHEMISTRY, 2008, 80 (23) : 9131 - 9134
  • [40] Microfluidic paper-based devices for bioanalytical applications
    Santhiago, Murilo
    Nery, Emilia W.
    Santos, Glauco P.
    Kubota, Lauro T.
    BIOANALYSIS, 2014, 6 (01) : 89 - 106