Quantitative analysis for sweat-absorbing times of paper-based microfluidic chips

被引:0
|
作者
Huang, Heyue [1 ,2 ,3 ]
Xu, Chuanpei [1 ,3 ]
Long, Peng [4 ,5 ]
Chen, Yanzhang [1 ,3 ]
Huang, Xijun [1 ,3 ]
Liu, Zheng [2 ]
Yang, Hong [1 ,3 ]
机构
[1] Guilin Univ Elect Technol, Sch Elect Engn & Automat, Guilin 541004, Guangxi, Peoples R China
[2] Guilin Univ Aerosp Technol, Sch Elect Informat & Automat, Guilin 541004, Guangxi, Peoples R China
[3] Guangxi Key Lab Automat Detecting Technol & Instru, Guilin 541004, Guangxi, Peoples R China
[4] Cent South Univ, Sch Energy Sci & Engn, Changsha 410083, Hunan, Peoples R China
[5] Guilin Univ Aerosp Technol, Sch Energy & Bldg Environm, Guilin 541004, Guangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
The structure of paper-based microfluidic chips; Sweat-absorbing time; Richards' equation; H value; Finite element analysis; ELECTROCHEMICAL DETECTION; GLUCOSE; DEVICES;
D O I
10.1007/s10404-023-02696-7
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Structures of paper-based microfluidic chips affect the sweat- absorbing time when they are used for sweat analysis. For the first time, we use COMSOL to establish two types of paper-based chip sweat-absorbing models that can quantitatively analyze this phenomenon. The standard model contains 1089 sweat glands, and the simplified model simplifies it according to the idea of finite element division, including 81 sweat glands. Sweat flows in from the bottom of the paper-based chip and out from the electrode contact surface (the upper surface of the central cylinder of the paper-based chip). Both models contain six paper-based chip structures, use Richards' equation as the governing equation, set the outflow velocity to 0, and set the sweating rate of a sweat gland at 0.6 mu L/min. In the standard model, it takes only 46 s for the paper-based structure with the fastest sweat-absorbing speed to completely saturate the electrode contact surface with sweat (meaning the sweat-absorbing time is 46 s), which is 13.06% shorter than that of the slowest structure. In the simplified model, the top 3 structures of sweat-absorbing speed are consistent with the standard model. The simulation results show that the sweat-absorbing time is positively correlated with the H value of the bottom surface of the paper-based structure (defined as the area of the bottom surface /the area of sweat glands covered by the bottom surface), which can be proved by analytical and experimental methods. The analytical method proves that this conclusion can be generalized to other sweating rate conditions.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Quantitative analysis for sweat-absorbing times of paper-based microfluidic chips
    Heyue Huang
    Chuanpei Xu
    Peng Long
    Yanzhang Chen
    Xijun Huang
    Zheng Liu
    Hong Yang
    [J]. Microfluidics and Nanofluidics, 2024, 28
  • [2] Applications of microfluidic paper-based chips in environmental analysis and detection
    Zhang Yu
    Qi Ji
    Lie Feng
    Wang Ning
    Sun Xiyan
    Cui Rong
    Yu Jialuo
    Ye Jiaming
    Liu Ping
    Li Bowei
    Chen Lingxin
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (08) : 802 - 815
  • [3] Isoelectric focusing on microfluidic paper-based chips
    Yu, Siyang
    Yan, Chunfang
    Hu, Xianqiao
    He, Baoqi
    Jiang, Yan
    He, Qiaohong
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (21) : 5415 - 5422
  • [4] Isoelectric focusing on microfluidic paper-based chips
    Siyang Yu
    Chunfang Yan
    Xianqiao Hu
    Baoqi He
    Yan Jiang
    Qiaohong He
    [J]. Analytical and Bioanalytical Chemistry, 2019, 411 : 5415 - 5422
  • [5] Fabrication Techniques of Microfluidic Paper-Based Chips and Their Applications
    Jiang Yan
    Ma Cuicui
    Hu Xianqiao
    He Qiaohong
    [J]. PROGRESS IN CHEMISTRY, 2014, 26 (01) : 167 - 177
  • [6] The Road to Unconventional Detections: Paper-Based Microfluidic Chips
    Jin, Yuhang
    Aziz, Aziz Ur Rehman
    Wu, Bin
    Lv, Ying
    Zhang, Hangyu
    Li, Na
    Liu, Bo
    Zhang, Zhengyao
    [J]. MICROMACHINES, 2022, 13 (11)
  • [7] Skin-Interfaced Bifluidic Paper-Based Device for Quantitative Sweat Analysis
    Deng, Muhan
    Li, Xiaofeng
    Song, Kui
    Yang, Hanlin
    Wei, Wenkui
    Duan, Xiaojun
    Ouyang, Xiaoping
    Cheng, Huanyu
    Wang, Xiufeng
    [J]. ADVANCED SCIENCE, 2024, 11 (10)
  • [8] Analysis on paper-based microfluidic systems
    Whitesides, George M.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [9] Paper-based microfluidic chip for sweat volume, ECG and EMG monitoring
    Yang, Hanbo
    Li, Gang
    Wang, Junyao
    Hou, Qi
    Pan, Hongxu
    Quan, Jingran
    Chen, Yansong
    Xu, Jianxin
    Liu, Yahao
    Liu, Huan
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2024, 371
  • [10] A Smartwatch Integrated with a Paper-based Microfluidic Patch for Sweat Electrolytes Monitoring
    Cao, Qingpeng
    Liang, Bo
    Mao, Xiyu
    Wei, Jinwei
    Tu, Tingting
    Fang, Lu
    Ye, Xuesong
    [J]. ELECTROANALYSIS, 2021, 33 (03) : 643 - 651