Investigation on Tuning Power-Frequency Droop for Improved Grid-Forming Inverter and Synchronous Generator Transient Load Sharing

被引:3
|
作者
Westman, Jan [1 ]
Hadidi, Ramtin [1 ]
机构
[1] Clemson Univ, Dept Elect & Comp Engn, Charleston, SC 29405 USA
关键词
grid-forming inverters; small-signal analysis; synchronous generators; transient load sharing; MICROGRIDS; OPERATION;
D O I
10.3390/en16186758
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Poor transient load sharing has been observed during the parallel operation of synchronous generators (SGs) and droop-controlled grid-forming (GFM) inverter-based resources (IBRs) in islanded microgrids. This can result in overcurrent protections, causing the inverters to trip, which leads to the collapse of voltage and frequency. In this article, small-signal analysis supported by electromagnetic transients (EMTs) simulation is performed on a detailed model of a microgrid containing IBRs and an SG to identify underdamped modes and their sensitivities to the power-frequency (P-F) droop parameter. Further EMT simulation of a more complex microgrid model with multiple GFM IBRs and SGs is performed to determine whether trends identified from the modal analysis extend to cases where the number of SGs in operation may vary. The objective is to investigate the effectiveness of tuning this parameter to reduce the likelihood of overcurrents in response to load and generation disturbances. The work uncovers both fast and slow modes of concern. Primarily, the findings show that increasing the P-F droop value improves the damping of the slower mode while degrading the damping of the faster mode, leading to an upper limit on the damping improvement of the GFM IBR output current. In EMT simulations of the more complex microgrid, the greatest damping improvement still exhibits significant maximum overshoot. Furthermore, the optimal value of the P-F droop parameter is sensitive to the number of SGs in operation. The conclusion is that tuning the P-F droop parameter is not an effective means to avoid the overcurrent tripping of GFM IBRs during response to large load or generation disturbances when operating in parallel to SGs in islanded microgrids.
引用
收藏
页数:24
相关论文
共 45 条
  • [41] Advanced Current-Limiting and Power-Sharing Control in a PV-Based Grid-Forming Inverter Under Unbalanced Grid Conditions
    Yazdani, Sara
    Ferdowsi, Mehdi
    Davari, Masoud
    Shamsi, Pourya
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2020, 8 (02) : 1084 - 1096
  • [42] Low-Frequency Passivity-Based Analysis and Damping of Power-Synchronization Controlled Grid-Forming Inverter
    Zhao, Fangzhou
    Wang, Xiongfei
    Zhu, Tianhua
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2023, 11 (02) : 1542 - 1554
  • [43] Droop control-based fast frequency support of wind power generation integrated grid-forming VSC-HVDC system
    Chen, Qian
    Shi, Gang
    Lu, Yi
    Qiu, Peng
    Zhou, Jianqiao
    Yang, Renxin
    Zhang, Jianwen
    FRONTIERS IN ENERGY RESEARCH, 2024, 12
  • [44] Comparative Analysis and Improvement of Generalized Droop Control and Virtual Synchronous Generator for Rate of Change of Frequency Constraint and Transient Power Suppression
    Wu, Qinghui
    Zhang, Chunjiang
    Zhao, Xiaojun
    Lin, Hengwei
    Zhang, Xiaoyu
    Wang, Fuxi
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2024,
  • [45] An improved damping adaptive grid-forming control for black start of permanent magnet synchronous generator wind turbines supported with battery energy storage system
    Meng, Jianhui
    Wang, Dongxu
    Wang, Yi
    Guo, Feng
    Yu, Jie
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (02) : 354 - 366