Correction method for dynamic measurement with an optical lever AFM (Effects of ambient fluid and surface force)

被引:1
|
作者
Hanamitsu, Yuki [1 ]
Ishikawa, Takumi [1 ]
Matsuoka, Hiroshige [1 ]
机构
[1] Tottori Univ, 4-101 Koyama Cho Minami, Tottori 6808552, Japan
关键词
Atomic force microscope; Optical lever; Surface force; Ambient fluid; Amplitude ratio; Dynamic measurement; Correction factor; MICROSCOPE; CALIBRATION;
D O I
10.1299/jamdsm.2023jamdsm0051
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Cantilever vibration in an optical lever AFM is theoretically analyzed considering the effect of surface force and ambient fluid. The surface force between the tip and the sample is modeled using a cantilever with a spring and damping added to the tip, and the effect of ambient fluid on the cantilever vibration is analyzed using the bead model. The amplitude ratios of the forced vibration were derived by solving the equation of motion. There are discrepancies between the amplitude ratio derived from bending vibration theory and that obtained through the optical lever method. The amplitude ratio from bending vibration theory reveals that the effect of surface force dominates primarily below the second resonant frequency. The tip-added spring affects the resonant frequency shift and amplitude ratio, while the tip-added damping mainly affects the amplitude ratio at the resonant frequency. In contrast, the amplitude ratio considering the optical lever method reveals that anti-resonance occurs when the tip-added spring constant is positive, which is not observed in bending vibration theory. The amplitude ratio of the cantilever is modified by introducing a correction factor. The correction factor decreases with excitation frequency except for the frequency where the anti-resonance occurs. The correction factor becomes small when the ambient fluid has high density and viscosity.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Accurate fluid force measurement based on control surface integration
    Lentink, David
    EXPERIMENTS IN FLUIDS, 2018, 59 (01)
  • [32] Method for immobilizing microbial cells on gel surface for dynamic AFM studies
    Gad, M
    Ikai, A
    BIOPHYSICAL JOURNAL, 1995, 69 (06) : 2226 - 2233
  • [33] Evaluation of the Sensing Block Method for Dynamic Force Measurement
    Zhang Qinghui
    Chen Hao
    Li Wenzhao
    Song Li
    SEVENTH INTERNATIONAL CONFERENCE ON ELECTRONICS AND INFORMATION ENGINEERING, 2017, 10322
  • [34] Development of a dynamic surface shape measurement for magnetic fluid
    Zhang, Xining
    Xiang, Zhou
    Xia, XinRui
    Zhang, Haixing
    FLOW MEASUREMENT AND INSTRUMENTATION, 2019, 66 : 50 - 59
  • [35] Evaluation of optical supersmooth surface using AFM and comparison with interference method
    Li, JB
    Li, DC
    Zhang, XL
    Li, XY
    Zhao, AQ
    CURRENT DEVELOPMENTS IN OPTICAL ELEMENTS AND MANUFACTURING, 1998, 3557 : 336 - 344
  • [36] Effect of cantilever geometry on the optical lever sensitivities and thermal noise method of the atomic force microscope
    Sader, John E.
    Lu, Jianing
    Mulvaney, Paul
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [37] Surface effects of dynamic force microscopy in liquids
    Rankl, C
    Hinterdorfer, P
    Kienberger, F
    Zhu, R
    Pastushenko, V
    BIOPHYSICAL JOURNAL, 2003, 84 (02) : 468A - 468A
  • [38] A force measurement method using the optical fibre beam
    Chinpon, A.
    Thamaphat, K.
    Hansuparnusorn, M.
    Limsuwan, P.
    ISEEC, 2012, 32 : 989 - 993
  • [39] Measuring the Interaction Force Between a Droplet and a Super-hydrophobic Substrate by the Optical Lever Method
    Zhuang, Shuya
    Zhao, Meirong
    Wang, Zhiyi
    Zhang, Lele
    Huang, Yinguo
    Zheng, Yelong
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (148):
  • [40] A COMPARISON OF FORCE AND OPTICAL TECHNIQUES FOR THE MEASUREMENT OF DYNAMIC CONTACT ANGLES
    SEEBERGH, JE
    BERG, JC
    CHEMICAL ENGINEERING SCIENCE, 1992, 47 (17-18) : 4468 - 4470