The Changes in Ocular Biomechanical Response Parameters and Intraocular Pressure After Surgical Treatment for Thyroid Eye Disease

被引:1
|
作者
Hsia, Yun [1 ,2 ]
Wei, Yi-Hsuan [2 ,3 ]
Liao, Shu-Lang [2 ,3 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Ophthalmol, Hsin Chu Branch, Hsinchu, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Ophthalmol, 7 Chung Shan South Rd, Taipei, Taiwan
[3] Natl Taiwan Univ, Coll Med, Taipei, Taiwan
关键词
thyroid eye disease; orbital decompression; anterior blepharotomy; ocular biomechanical properties; Corvis ST; ORBITAL DECOMPRESSION; GRAVES OPHTHALMOPATHY; PATHOGENESIS; ORBITOPATHY; MANAGEMENT; GLAUCOMA;
D O I
10.1167/iovs.64.10.31
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate changes in ocular biomechanical response parameters and intraocular pressure (IOP) in patients with thyroid eye disease (TED) undergoing orbital decompression or anterior blepharotomy. METHODS. Eighty-three eyes from 46 patients receiving orbital decompression (the orbital decompression group) and 45 eyes from 28 patients receiving anterior blepharotomy (the anterior blepharotomy group) were retrospectively enrolled from a tertiary center. Corvis ST tonometry was used to assess ocular biomechanical response and biomechanically corrected IOP (bIOP) pre- and postoperatively. Non-contact tonometry (IOP-NCT) was also performed. RESULTS. In the anterior blepharotomy group, the margin reflex distance decreased (P < 0001). The highest concavity radius (P = 0.026) and whole eye movement (P = 0.003) increased. Neither IOP-NCT nor bIOP had a significant change. In the orbital decompression group, the extent of exophthalmos decreased (P < 0.001). The A2 length (P = 0.009) decreased. The bIOP did not show a significant change (16.4 +/- 2.7 vs. 16.7 +/- 4.5; P = 0.415), but the IOP-NCT decreased significantly (17.5 +/- 3.3 vs. 16.0 +/- 3.3; P < 0.001). Higher baseline IOP-NCT ( beta = -0.40, P < 0.001) and greater reduction in stiffness parameter A1 (SP-A1; beta = 0.05, P = 0.002) were associated with more significant IOP-NCT reduction after the orbital decompression. CONCLUSIONS. Ocular biomechanical response parameters may change after TED surgery, potentially affecting IOP measurements, particularly in patients receiving orbital decompression.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Evaluation of the influence of corneal biomechanical properties on Intraocular pressure measurements using the Ocular Response Analyzer
    Medeiros, Felipe A.
    Weinreb, Robert N.
    JOURNAL OF GLAUCOMA, 2006, 15 (05) : 364 - 370
  • [42] Analysis of Fellow Eye Intraocular Pressure Changes After Glaucoma Surgery in 1 Eye
    Rajurkar, Ketaki
    Pegu, Julie
    Dubey, Suneeta
    Kumar, Ashwini
    Singh, Nishtha
    JOURNAL OF GLAUCOMA, 2018, 27 (04) : E90 - E91
  • [43] Changes in Ocular Response Analyzer Parameters After LASIK
    Chen, Shihao
    Chen, Ding
    Wang, Jianhua
    Lu, Fan
    Wang, Qinmei
    Qu, Jia
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (04) : 279 - 288
  • [44] Lens parameters as predictors of intraocular pressure changes after phacoemulsification
    Moghimi, S.
    Abdi, F.
    Latifi, G.
    Fakhraie, G.
    Ramezani, F.
    He, M.
    Lin, S. C.
    EYE, 2015, 29 (11) : 1469 - 1476
  • [45] Lens parameters as predictors of intraocular pressure changes after phacoemulsification
    S Moghimi
    F Abdi
    G Latifi
    G Fakhraie
    F Ramezani
    M He
    S C Lin
    Eye, 2015, 29 : 1469 - 1476
  • [46] Intraocular pressure changes in the contralateral eye after trabeculectomy with mitomycin C
    Leung, DYL
    Kwong, YYY
    Yuen, HKL
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (02) : 250 - 250
  • [47] Intraocular pressure changes in the contralateral eye after trabeculectomy with mitomycin C
    Vysniauskiene, I
    Shaarawy, T
    Flammer, J
    Haefliger, IO
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (07) : 809 - 811
  • [48] Intraocular pressure changes after treatment for Graves' orbitopathy
    Danesh-Meyer, HV
    Savino, PJ
    Deramo, V
    Sergott, RC
    Smith, AF
    OPHTHALMOLOGY, 2001, 108 (01) : 145 - 150
  • [49] Measurements of ocular properties in response to intraocular pressure changes using an ultrasonic system
    He, Xiaoyin
    Liu, Jun
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3026 - +
  • [50] Dynamic Response of Intraocular Pressure and Biomechanical Effects of the Eye Considering Fluid-Structure Interaction
    Salimi, S.
    Park, S. Simon
    Freiheit, T.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (09):