The Changes in Ocular Biomechanical Response Parameters and Intraocular Pressure After Surgical Treatment for Thyroid Eye Disease

被引:1
|
作者
Hsia, Yun [1 ,2 ]
Wei, Yi-Hsuan [2 ,3 ]
Liao, Shu-Lang [2 ,3 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Ophthalmol, Hsin Chu Branch, Hsinchu, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Ophthalmol, 7 Chung Shan South Rd, Taipei, Taiwan
[3] Natl Taiwan Univ, Coll Med, Taipei, Taiwan
关键词
thyroid eye disease; orbital decompression; anterior blepharotomy; ocular biomechanical properties; Corvis ST; ORBITAL DECOMPRESSION; GRAVES OPHTHALMOPATHY; PATHOGENESIS; ORBITOPATHY; MANAGEMENT; GLAUCOMA;
D O I
10.1167/iovs.64.10.31
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate changes in ocular biomechanical response parameters and intraocular pressure (IOP) in patients with thyroid eye disease (TED) undergoing orbital decompression or anterior blepharotomy. METHODS. Eighty-three eyes from 46 patients receiving orbital decompression (the orbital decompression group) and 45 eyes from 28 patients receiving anterior blepharotomy (the anterior blepharotomy group) were retrospectively enrolled from a tertiary center. Corvis ST tonometry was used to assess ocular biomechanical response and biomechanically corrected IOP (bIOP) pre- and postoperatively. Non-contact tonometry (IOP-NCT) was also performed. RESULTS. In the anterior blepharotomy group, the margin reflex distance decreased (P < 0001). The highest concavity radius (P = 0.026) and whole eye movement (P = 0.003) increased. Neither IOP-NCT nor bIOP had a significant change. In the orbital decompression group, the extent of exophthalmos decreased (P < 0.001). The A2 length (P = 0.009) decreased. The bIOP did not show a significant change (16.4 +/- 2.7 vs. 16.7 +/- 4.5; P = 0.415), but the IOP-NCT decreased significantly (17.5 +/- 3.3 vs. 16.0 +/- 3.3; P < 0.001). Higher baseline IOP-NCT ( beta = -0.40, P < 0.001) and greater reduction in stiffness parameter A1 (SP-A1; beta = 0.05, P = 0.002) were associated with more significant IOP-NCT reduction after the orbital decompression. CONCLUSIONS. Ocular biomechanical response parameters may change after TED surgery, potentially affecting IOP measurements, particularly in patients receiving orbital decompression.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Evaluation of changes in Ocular Biomechanical Properties and Intraocular pressure using Corvis ST after Orbital Decompression and Anterior Blepharotomy for Thyroid Eye Disease
    Cheng, Anny
    Hsia, Yun
    Wei, Yi-Hsuan
    Liao, Shu-Lang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [2] In vivo ocular biomechanical compliance in thyroid eye disease
    Vellara, Hans R.
    Hart, Richard
    Gokul, Akilesh
    McGhee, Charles N. J.
    Patel, Dipika V.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (08) : 1076 - 1079
  • [3] Intraocular Pressure and Glaucoma in Thyroid Eye Disease
    Betzler, Bjorn Kaijun
    Young, Stephanie M.
    Sundar, Gangadhara
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2022, 38 (03): : 219 - 225
  • [4] Ocular treatment of thyroid eye disease
    Eichhorn, Knut
    Harrison, Andrew R.
    Bothun, Erick D.
    McLoon, Linda K.
    Lee, Michael S.
    EXPERT REVIEW OF OPHTHALMOLOGY, 2010, 5 (03) : 313 - 324
  • [5] Ocular fundus pulsation changes as a response to increased intraocular pressure in the posterior rat eye
    Augustin, Marco
    Fialova, Stanislava
    Fischak, Corinna
    Schmetterer, Leopold
    Hitzenberger, Christoph K.
    Baumann, Bernhard
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [6] Corneal biomechanical changes and intraocular pressure in patients with thyroid orbitopathy
    Zofia Pniakowska
    Anna Klysik
    Roman Gos
    Piotr Jurowski
    International Journal of Ophthalmology, 2016, (03) : 439 - 443
  • [7] Corneal biomechanical changes and intraocular pressure in patients with thyroid orbitopathy
    Pniakowska, Zofia
    Klysik, Anna
    Gos, Roman
    Jurowski, Piotr
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (03) : 439 - 443
  • [8] Ocular Surface Changes in Treatment-Naive Thyroid Eye Disease
    Liao, Xulin
    Lai, Kenneth Ka Hei
    Aljufairi, Fatema Mohamed Ali Abdulla
    Chen, Wanxue
    Hu, Zhichao
    Wong, Hanson Yiu Man
    Jia, Ruofan
    Wei, Yingying
    Tham, Clement Chee Yung
    Pang, Chi Pui
    Chong, Kelvin Kam Lung
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (09)
  • [9] Ocular Surface Changes in Thyroid Eye Disease
    Ismailova, Dilyara S.
    Fedorov, Anatoly A.
    Grusha, Yaroslav O.
    ORBIT-AN INTERNATIONAL JOURNAL ON ORBITAL DISORDERS AND FACIAL RECONSTRUCTIVE SURGERY, 2013, 32 (02): : 87 - 90
  • [10] Intraocular pressure and ocular biometric parameters changes in migraine
    Koban, Yaran
    Ozlece, Hatice Kose
    Bilgin, Gorkem
    Koc, Mustafa
    Cagatay, Halil Huseyin
    Durgunlu, Emre I.
    Burcu, Ayse
    BMC OPHTHALMOLOGY, 2016, 16