Rapid and visual identification of HIV-1 using reverse transcription loop-mediated isothermal amplification integrated with a gold nanoparticle-based lateral flow assay platform

被引:9
|
作者
Chen, Xu [1 ,2 ]
Du, Cheng [3 ]
Zhao, Qiang [4 ]
Zhao, Qi [5 ]
Wan, Yonghu [6 ]
He, Jun [4 ]
Yuan, Wei [7 ]
机构
[1] Guizhou Univ Tradit Chinese Med, Clin Coll 2, Guiyang, Guizhou, Peoples R China
[2] Guizhou Univ Tradit Chinese Med, Affiliated Hosp 2, Clin Med Lab, Guiyang, Guizhou, Peoples R China
[3] Guizhou Univ Tradit Chinese Med, Affiliated Hosp 2, Dept Anesthesiol, Guiyang, Guizhou, Peoples R China
[4] Guizhou Prov Ctr, Clin Lab, Guiyang, Guizhou, Peoples R China
[5] Guizhou Univ Tradit Chinese Med, Gastroenterol Affiliated Hosp 2, Guiyang, Guizhou, Peoples R China
[6] Guizhou Prov Ctr Dis Control & Prevent, Expt Ctr, Guiyang, Guizhou, Peoples R China
[7] Guizhou Prov Ctr Clin Lab, Dept Qual Control, Guiyang, Guizhou, Peoples R China
关键词
human immunodeficiency virus type one; loop-mediated isothermal amplification; gold nanoparticle-based lateral flow assay; point-of-care platform; limit of detection; DRUG-RESISTANCE; INFECTION;
D O I
10.3389/fmicb.2023.1230533
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Human immunodeficiency virus type one (HIV-1) infection remains a major public health problem worldwide. Early diagnosis of HIV-1 is crucial to treat and control this infection effectively. Here, for the first time, we reported a novel molecular diagnostic assay called reverse transcription loop-mediated isothermal amplification combined with a visual gold nanoparticle-based lateral flow assay (RT-LAMP-AuNPs-LFA), which we devised for rapid, specific, sensitive, and visual identification of HIV-1. The unique LAMP primers were successfully designed based on the pol gene from the major HIV-1 genotypes CRF01_AE, CRF07_BC, CRF08_BC, and subtype B, which are prevalent in China. The optimal HIV-1-RT-LAMP-AuNPs-LFA reaction conditions were determined to be 68 & DEG;C for 35 min. The detection procedure, including crude genomic RNA isolation (approximately 5 min), RT-LAMP amplification (35 min), and visual result readout (<2 min), can be completed within 45 min. Our assay has a detection limit of 20 copies per test, and we did not observe any cross-reactivity with any other pathogen in our testing. Hence, our preliminary results indicated that the HIV-1-RT-LAMP-AuNPs-LFA assay can potentially serve as a useful point-of-care diagnostic tool for HIV-1 detection in a clinical setting.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Sequence-Specific Detection Method for Reverse Transcription, Loop-Mediated Isothermal Amplification of HIV-1
    Curtis, Kelly A.
    Rudolph, Donna L.
    Owen, Michele
    JOURNAL OF MEDICAL VIROLOGY, 2009, 81 (06) : 966 - 972
  • [22] A Reverse Transcription Loop-Mediated Isothermal Amplification Assay Optimized to Detect Multiple HIV Subtypes
    Ocwieja, Karen E.
    Sherrill-Mix, Scott
    Liu, Changchun
    Song, Jinzhao
    Bau, Haim
    Bushman, Frederic D.
    PLOS ONE, 2015, 10 (02):
  • [23] Rapid and Visual Differentiation of Mycobacterium tuberculosis From the Mycobacterium tuberculosis Complex Using Multiplex Loop-Mediated Isothermal Amplification Coupled With a Nanoparticle-Based Lateral Flow Biosensor
    Yang, Xinggui
    Huang, Junfei
    Chen, Xu
    Xiao, Ziyu
    Wang, Xiaojuan
    Chen, Yijiang
    Zheng, Wenlin
    Chen, Wei
    Chen, Huijuan
    Lei, Shiguang
    Hu, Yong
    Li, Shijun
    FRONTIERS IN MICROBIOLOGY, 2021, 12
  • [24] Rapid identification of Aconitum plants based on loop-mediated isothermal amplification assay
    Masashi Kitamura
    Akira Kazato
    Tadashi Yamamuro
    Hirokazu Ando
    Yohei Sasaki
    Ryuichiro Suzuki
    Yoshiaki Shirataki
    BMC Research Notes, 12
  • [25] Rapid identification of Aconitum plants based on loop-mediated isothermal amplification assay
    Kitamura, Masashi
    Kazato, Akira
    Yamamuro, Tadashi
    Ando, Hirokazu
    Sasaki, Yohei
    Suzuki, Ryuichiro
    Shirataki, Yoshiaki
    BMC RESEARCH NOTES, 2019, 12 (1)
  • [26] Rapid identification of Takifugu genus using visual loop-mediated isothermal amplification
    Xie, Ruibin
    Li, Hui
    Yu, Wenjie
    Wang, Nan
    Zhang, Juan
    Gao, Jie
    Chen, Ailiang
    JOURNAL OF FOOD SCIENCE, 2022, 87 (02) : 867 - 877
  • [27] Development of a loop-mediated isothermal amplification assay combined with a nanoparticle-based lateral flow biosensor for rapid detection of plasmid-mediated colistin resistance gene mcr-1
    Gong, Lin
    Tang, Fei
    Liu, Ernan
    Liu, Xiaoli
    Xu, Huiqiong
    Wang, Yimei
    Song, Yadong
    Liang, Jiansheng
    PLOS ONE, 2021, 16 (04):
  • [28] Rapid and sensitive detection of Senecavirus A by reverse transcription loop-mediated isothermal amplification combined with a lateral flow dipstick method
    Li, Jinhui
    Liang, Weifang
    Xu, Shuaifei
    Shi, Jian
    Zhou, Xia
    Liu, Bowen
    Yu, Li
    Xiong, Jingfeng
    Si, Guangbin
    He, Dongsheng
    PLOS ONE, 2019, 14 (05):
  • [29] Loop-Mediated Isothermal Amplification Coupled With Nanoparticle-Based Lateral Biosensor for Rapid, Sensitive, and Specific Detection of Bordetella pertussis
    Sun, Chunrong
    Xiao, Fei
    Fu, Jin
    Huang, Xiaolan
    Jia, Nan
    Xu, Zheng
    Wang, Yi
    Cui, Xiaodai
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 9
  • [30] Rapid and visual detection of human enterovirus coxsackievirus A16 by reverse transcription loop-mediated isothermal amplification combined with lateral flow device
    Yan, G.
    Jun, L.
    Kangchen, Z.
    Yiyue, G.
    Yang, Y.
    Xiaoyu, Z.
    Zhiyang, S.
    Lunbiao, C.
    LETTERS IN APPLIED MICROBIOLOGY, 2015, 61 (06) : 531 - 537