Test-Retest Reliability and Convergent Validity of Piezoelectric Force Plate Measures of Single-Leg Sit-to-Stand Performance in Trained Adults

被引:3
|
作者
Makaraci, Yucel [1 ]
Nas, Kazim [1 ]
Ruiz-Cardenas, Juan D. [2 ]
Gunduz, Kerem [3 ]
Aydemir, Mustafa [3 ]
Orange, Samuel T. [4 ,5 ]
机构
[1] Karamanoglu Mehmetbey Univ, Fac Sports Sci, Dept Coaching Educ, Karaman, Turkiye
[2] Univ Catolica Murcia, Physiotherapy Dept, Fac Hlth Sci, Murcia, Spain
[3] Karamanoglu Mehmetbey Univ, Inst Hlth Sci, Dept Sports Sci, Karaman, Turkiye
[4] Newcastle Univ, Sch Biomed Nutrit & Sport Sci, Fac Med Sci, Newcastle Upon Tyne, Tyne & Wear, England
[5] Newcastle Univ, Newcastle Univ Ctr Canc, Newcastle Upon Tyne, Tyne & Wear, England
关键词
reliability; validity; functional strength; kinetic chain; limb symmetry index; lower extremity; unilateral jump; FUNCTIONAL PERFORMANCE; ASYMMETRY; STRENGTH; BALANCE; MUSCLE; POWER; VELOCITY; ABILITY;
D O I
10.1519/JSC.0000000000004489
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The single-leg sit-to-stand (STS) test has emerged as a promising method of assessing lower-limb functional strength and asymmetry. However, the reliability of its performance parameters on a force plate has not been explored. This study examined the test-retest reliability and convergent validity of the single-leg STS test performed on a piezoelectric-based force plate in trained subjects. Thirty trained male adults (age: 21.4 +/- 1.7 years) performed 3 separate single-leg STS days of testing to assess both intraday and interday reliability. Performance parameters included STS time, ground reaction force (GRF), and center of pressure (CoP) sway velocity. The relationship between single-leg STS parameters and unilateral countermovement jump (CMJ) variables was assessed for convergent validity. Intraclass correlation coefficient (ICC) and coefficient of variation (CV) were calculated for reliability analyses, and convergent validity was assessed with Spearman's correlation coefficient (rho). In the dominant leg, single-leg performance parameters showed moderate-to-excellent intraday reliability (ICC = 0.65-0.90, CV = 4.3-11.2%) and moderate interday reliability (ICC = 0.54-0.74, CV = 5.8-13.5%). In the nondominant leg, all single-leg STS performance parameters showed good intraday (ICC = 0.79-0.86, CV = 3.8-9.8%) and interday reliability (ICC = 0.75-0.82, CV = 4.6-9.7%). STS times in the dominant and nondominant legs were inversely related to unilateral CMJ velocity (rho = -0.47 and -0.38, respectively). CoP sway velocity in the nondominant leg showed positive correlations with unilateral CMJ power and velocity (rho = 0.38 and 0.54, respectively). In conclusion, the force plate-based single-leg STS test provides reliable measures of STS time, GRF, and CoP sway velocity in trained adults and could be used to assess lower-limb function and asymmetry.
引用
收藏
页码:2373 / 2380
页数:8
相关论文
共 50 条
  • [31] TEST-RETEST RELIABILITY OF MAXIMAL LEG MUSCLE POWER AND FUNCTIONAL PERFORMANCE MEASURES IN PATIENTS WITH SEVERE OSTEOARTHRITIS (OA)
    Villadsen, A.
    Roos, E. M.
    Overgaard, S.
    Holsgaard-Larsen, A.
    OSTEOARTHRITIS AND CARTILAGE, 2010, 18 : S72 - S73
  • [32] Five Times Sit-to-Stand Test in people with non-specific chronic low back pain-a cross-sectional test-retest reliability study
    Ozudogru, Anil
    Canli, Mehmet
    Ceylan, Ismail
    Kuzu, Safak
    Alkan, Halil
    Karacay, Basak Cigdem
    IRISH JOURNAL OF MEDICAL SCIENCE, 2023, 192 (04) : 1903 - 1908
  • [33] Convergent validity and test-retest reliability in free-living conditions of the Yamax digiwalker pedometer and the MTI accelerometer in obese adults
    Hemmingsson, E
    Page, A
    Ekelund, U
    Rössner, S
    INTERNATIONAL JOURNAL OF OBESITY, 2004, 28 : S208 - S208
  • [34] Test-retest reliability of three-dimensional kinematics using an electromagnetic tracking system during single-leg squat and stepping maneuver
    Nakagawa, Theresa H.
    Uehara Moriya, Erika Tiemi
    Maciel, Carlos D.
    Serrao, Fabio V.
    GAIT & POSTURE, 2014, 39 (01) : 141 - 146
  • [35] Assessment of balance in overweight and obese young adults: utilizing centre of pressure displacement variables in the single leg sit-to-stand test
    Sangkarit, Noppharath
    Tapanya, Weerasak
    Amput, Patchareeya
    Muangchuen, Chananya
    Seeta, Piyaporn
    Paleeta, Worrasak
    INTERNATIONAL JOURNAL OF ADOLESCENCE AND YOUTH, 2025, 30 (01)
  • [36] Test-Retest Reliability of Single Leg Jump Performance Using the Drift Protocol in Division I Baseball Pitchers
    Bergquist, Amy M.
    Lebron, Modesto A.
    Mangum, L. Colby
    Stout, Jeffrey R.
    Fukuda, David H.
    JOURNAL OF SCIENCE IN SPORT AND EXERCISE, 2023,
  • [37] TEST-RETEST RELIABILITY OF POSTURAL SWAY MEASURES DURING STATIC STANDING BALANCE PERFORMANCE IN HEALTHY ELDERLY ADULTS
    Kwon, Yu-Ri
    Eom, Gwang-Moon
    Kim, Ji-Won
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2022, 22 (08)
  • [38] Test-retest reliability and convergent validity of (R)-[11C]PK11195 outcome measures without arterial input function
    Pontus Plavén-Sigray
    Granville James Matheson
    Zsolt Cselényi
    Aurelija Jucaite
    Lars Farde
    Simon Cervenka
    EJNMMI Research, 8
  • [39] Test-retest reliability and convergent validity of (R)-[11C]PK11195 outcome measures without arterial input function
    Plaven-Sigray, Pontus
    Matheson, Granville James
    Cselenyi, Zsolt
    Jucaite, Aurelija
    Farde, Lars
    Cervenka, Simon
    EJNMMI RESEARCH, 2018, 8
  • [40] Benton Visual Retention Test Performance in Normal Adults and Acute Stroke Patients: Demographic Considerations, Discriminant Validity, and Test-Retest Reliability
    Messinis, Lambros
    Lyros, Epameinondas
    Georgiou, Vassilis
    Papathanasopoulos, Panagiotis
    CLINICAL NEUROPSYCHOLOGIST, 2009, 23 (06) : 962 - 977