Development and validation of liquid chromatography-tandem mass spectrometry method to quantify dasatinib in plasma and its application to a pharmacokinetic study

被引:0
|
作者
Costa, Edlaine Rijo [1 ]
Castro, Thales Nascimento [2 ]
Goncalves-de-Albuquerque, Cassiano Felippe [3 ]
Neto, Hugo Caire de Castro Faria [3 ]
Goncalves, Jose Carlos Saraiva [1 ]
Estrela, Rita de Cassia Elias [1 ,2 ]
机构
[1] Univ Fed Rio de Janeiro, Fac Pharm, Pharmacometry Lab, Rio de Janeiro, RJ, Brazil
[2] Fundacao Oswaldo Cruz, Lab Clin Res STD & AIDS, Evandro Chagas Natl Inst Infect Dis, Rio de Janeiro, RJ, Brazil
[3] Fundacao Oswaldo Cruz, Oswaldo Cruz Inst, Lab Immunopharmacol, Rio de Janeiro, Brazil
关键词
LC-MS/MS; Liquid-liquid extraction; Dasatinib; Mice plasma; Pharmacokinetics; TYROSINE KINASE INHIBITORS; LC-MS/MS METHOD; SIMULTANEOUS QUANTIFICATION; ACTIVE METABOLITES; SEVERE SEPSIS; IMATINIB; NILOTINIB; SRC; SORAFENIB; SUNITINIB;
D O I
10.1590/s2175-97902023e21415
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Dasatinib, a potent oral multi-targeted kinase inhibitor against Src and Bcr-Abl, can decrease inflammatory response in sepsis. A simple and cost-effective method for determination of an effective dose dasatinib was established. This method was validated in human plasma, with the aim of reducing the number of animals used, thus, avoiding ethical problems. Dasatinib and internal standard lopinavir were extracted from 180 uL of plasma using liquid-liquid extraction with methyl tert-butil ether, followed by liquid chromatography coupled to triple quadrupole mass spectrometry in multiple reaction monitoring mode. For the pharmacokinetic study, 1 mg/kg of dasatinib was administered to mice with and without sepsis. The method was linear over the concentration range of 1-98 ng/mL for DAS in mice and human plasma, with r2>0.99 and presented intra- and interday precision within the range of 2.3 - 6.2 and 4.3 - 7.0%, respectively. Further intra- and interday accuracy was within the range of 88.2 - 105.8 and 90.6 - 101.7%, respectively. The mice with sepsis showed AUC0-t = 2076.06 h*ng/mL and Cmax = 102.73 ng/mL and mice without sepsis presented AUC0-t = 2128.46 h*ng/mL. Cmax = 164.5 ng/mL. The described analytical method was successfully employed in pharmacokinetic study of DAS in mice.
引用
下载
收藏
页数:13
相关论文
共 50 条
  • [31] Determination of sitafloxacin in human plasma by liquid chromatography-tandem mass spectrometry method: Application to a pharmacokinetic study
    Huang, Kai
    Yang, Jie
    Zhang, Jing
    Ding, Ying
    Chen, Lan
    Xu, Wen-Yan
    Xu, Xue-Jiao
    Duan, Ru
    He, Qing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 957 : 36 - 40
  • [32] Development and validation of a bioanalytical method of analyzing 3′- and 6′-sialyllactose using liquid chromatography-tandem mass spectrometry in minipig plasma and its application in a pharmacokinetic study
    Eom, Han Young
    Jang, Seok-In
    Hwang, Jeong Ho
    Kim, Lila
    Kang, Jong Seong
    Lee, Jong-Hwa
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 195
  • [33] Development and validation of a liquid chromatography-tandem mass spectrometry assay for the simultaneous quantitation of prednisolone and dipyridamole in human plasma and its application in a pharmacokinetic study
    Chen, Mei
    Granvil, Camille
    Ji, Qin C.
    Zhang, Zhi-Yi
    Padval, Mahesh V.
    Kansra, Vikram V.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (05) : 1241 - 1249
  • [34] Development and validation of a sensitive liquid chromatography/tandem mass spectrometry method for the determination of raddeanin A in rat plasma and its application to a pharmacokinetic study
    Liu, Yinhui
    Ma, Bo
    Zhang, Qi
    Ying, Hanjie
    Li, Jing
    Xu, Qiuyu
    Wu, Di
    Wang, Yonglu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 912 : 16 - 23
  • [35] Development and validation of an ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of baloxavir in rat plasma and its application to pharmacokinetic studies
    Mu, Hongli
    Zhang, Wenyu
    Song, Yuanming
    Liang, Rui
    Zhao, Hengli
    Song, Chunhong
    Wen, Qing
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (11)
  • [36] Development and validation of a liquid chromatography-tandem mass spectrometry method for topotecan determination in beagle dog plasma and its application in a bioequivalence study
    Ye, Ling
    Shi, Jian
    Wan, Shanhe
    Yang, Xiaoshan
    Wang, Ying
    Zhang, Jiajie
    Zheng, Dayong
    Liu, Zhongqiu
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (11) : 1532 - 1539
  • [37] Rapid and sensitive liquid chromatography-tandem mass spectrometry: Assay development, validation and application to a human pharmacokinetic study
    Song, Min
    Wang, Li
    Zhao, Hua
    Hang, Taijun
    Wen, Aidong
    Yang, Lin
    Jia, Lee
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 875 (02): : 515 - 521
  • [38] Development and validation of an ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of baloxavir in rat plasma and its application to pharmacokinetic studies
    Mu, Hongli
    Zhang, Wenyu
    Song, Yuanming
    Liang, Rui
    Zhao, Hengli
    Song, Chunhong
    Wen, Qing
    BIOMEDICAL CHROMATOGRAPHY, 2023,
  • [39] New validated liquid chromatography-tandem mass spectrometry method for the determination of Dacomitinib in human plasma and its application to a pharmacokinetic study
    Gupta, Tinku
    Sahoo, NaliniKanta
    Rambabu, Maddela
    Praveen, M.
    Charde, Shrikant
    Sahu, Madhusmita
    Chakrabarti, Prasun
    Hung, Bui Thanh
    Margala, Martin
    Unhelkar, Bhuvan
    Narayanankutty, Arunaksharan
    SEPARATION SCIENCE PLUS, 2024, 7 (02)
  • [40] Liquid Chromatography-Tandem Mass Spectrometry Method for Ticagrelor and its Active Metabolite Determination in Human Plasma: Application to a Pharmacokinetic Study
    Marsousi, Niloufar
    Rudaz, Serge
    Desmeules, Jules A.
    Daali, Youssef
    CURRENT ANALYTICAL CHEMISTRY, 2020, 16 (05) : 602 - 608