A Meta-Analysis and Systematic Review of Normothermic and Hypothermic Machine Perfusion in Liver Transplantation

被引:8
|
作者
Mugaanyi, Joseph [1 ,2 ]
Dai, Lei [1 ]
Lu, Changjiang [1 ]
Mao, Shuqi [1 ]
Huang, Jing [1 ]
Lu, Caide [1 ]
机构
[1] Ningbo Univ, Ningbo Med Ctr, Dept Hepatopancreato Biliary Surg, Affiliated Hosp,Li Huili Hosp, Ningbo 315040, Peoples R China
[2] Ningbo Univ, Sch Med, Ningbo 315211, Peoples R China
关键词
machine perfusion; normothermic; hypothermic; liver transplant; survival; EXTENDED-CRITERIA DONORS; STATIC COLD-STORAGE; OXYGENATED PERFUSION; RISK-FACTORS; PRESERVATION; DONATION; SURVIVAL; OUTCOMES; QUALITY; IMPACT;
D O I
10.3390/jcm12010235
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The gap between the demand and supply of donor livers is still a considerable challenge. Since static cold storage is not sufficient in marginal livers, machine perfusion is being explored as an alternative. The objective of this study was to assess (dual) hypothermic oxygenated machine perfusion (HOPE/D-HOPE) and normothermic machine perfusion (NMP) in contrast to static cold storage (SCS). Methods: Three databases were searched to identify studies about machine perfusion. Graft and patient survival and postoperative complications were evaluated using the random effects model. Results: the incidence of biliary complications was lower in HOPE vs. SCS (OR: 0.59, 95% CI: 0.36-0.98, p = 0.04, I-2: 0%). There was no significant difference in biliary complications between NMP and SCS (OR: 0.76, 95% CI: 0.41-1.40, p = 0.38, I-2: 55%). Graft and patient survival were significantly better in HOPE than in SCS (HR: 0.40, 95% CI: 0.23-0.71, p = 0.002, I-2: 0%) and (pooled HR: 0.43, 95% CI: 0.20-0.93, p = 0.03, I-2: 0%). Graft and patient survival were not significantly different between NMP and SCS. Conclusion: HOPE/D-HOPE and NMP are promising alternatives to SCS for donor liver preservation. They may help address the widening gap between the demand for and availability of donor livers by enabling the rescue and transplantation of marginal livers.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Reply: Acute rejection after liver transplantation with machine perfusion versus static cold storage: A systematic review and meta-analysis
    Maspero, Marianna
    Hashimoto, Koji
    Fairchild, Robert L.
    Schlegel, Andrea
    HEPATOLOGY, 2024, 79 (02) : E32 - E32
  • [32] Systematic review and meta-analysis of hypothermic machine perfusion versus static cold storage of kidney allografts on transplant outcomes
    O'Callaghan, J. M.
    Morgan, R. D.
    Knight, S. R.
    Morris, P. J.
    BRITISH JOURNAL OF SURGERY, 2013, 100 (08) : 991 - 1001
  • [33] Hypothermic oxygenated perfusion in liver transplantation: a meta-analysis of randomized controlled trials and matched studies
    Tang, Gang
    Zhang, Linyu
    Xia, Lingying
    Zhang, Jie
    Wei, Zhengqiang
    Zhou, Rongxing
    INTERNATIONAL JOURNAL OF SURGERY, 2024, 110 (01) : 464 - 477
  • [34] Author response to: Comment on: Cost-utility analysis of normothermic and hypothermic ex-situ machine perfusion in liver transplantation
    Zimmermann, Julia
    Carter, Alexander W.
    BRITISH JOURNAL OF SURGERY, 2022, 109 (11) : E124 - E124
  • [35] What Is The Evidence For Oxygenated Hypothermic Machine Perfusion in Kidney Transplantation? A Systematic Review
    Pall, K.
    O'Callaghan, J.
    Pengel, L.
    TRANSPLANTATION, 2014, 98 : 270 - 270
  • [36] Benefits of Hypothermic Oxygenated Perfusion Versus Static Cold Storage in Liver Transplant: A Comprehensive Systematic Review and Meta-analysis
    Feng, Guo-Ying
    Feng, Xu
    Tao, Jie
    Ao, Yu-Pei
    Wu, Xin-Hua
    Qi, Shi-Guai
    He, Ze -Bo
    Shi, Zheng-Rong
    JOURNAL OF CLINICAL AND EXPERIMENTAL HEPATOLOGY, 2024, 14 (03)
  • [37] Hypothermic Machine Perfusion in Liver Transplantation - A Randomized Trial
    Van Rijn, R.
    Schurink, I. J.
    de Vries, Y.
    van den Berg, A. P.
    Cerisuelo, M. Cortes
    Murad, S. Darwish
    Erdmann, J. I.
    Gilbo, N.
    de Haas, R. J.
    Heaton, N.
    van Hoek, B.
    Huurman, V. A. L.
    Jochmans, I.
    van Leeuwen, O. B.
    de Meijer, V. E.
    Monbaliu, D.
    Polak, W. G.
    Slangen, J. J. G.
    Troisi, R. I.
    Vanlander, A.
    de Jonge, J.
    Porte, R. J.
    NEW ENGLAND JOURNAL OF MEDICINE, 2021, 384 (15): : 1391 - 1401
  • [38] The Impact of Hypothermic Oxygenated Perfusion on Liver Viability - Tested during Normothermic Machine
    Boteon, Y.
    Laing, R. W.
    Bhogal, R. H.
    Schlegel, A.
    Smith, A.
    Mirza, D. F.
    Afford, S.
    Mergental, H.
    TRANSPLANTATION, 2017, 101 (05) : 64 - 65
  • [39] Reply to: "Comparing hypothermic oxygenated and normothermic liver machine perfusion: Translation matters"
    Parente, Alessandro
    Jiao, Chunbao
    Eden, Janina
    Dutkowski, Philipp
    Fairchild, Robert L.
    Schlegel, Andrea
    JOURNAL OF HEPATOLOGY, 2024, 80 (04) : e166 - e168
  • [40] Systematic Review and Meta-analysis of Aortohepatic Conduits in Liver Transplantation
    Reese, T.
    Oberkofler, C. E.
    Raptis, D. A.
    Dutkowski, P.
    Clavien, P. -A
    Petrowsky, H.
    TRANSPLANTATION, 2017, 101 (05) : 183 - 183