Correlation of shear-wave elastography parameters with the molecular subtype and axillary lymph node status in breast cancer

被引:7
|
作者
Kim, Hee Jeong [1 ,2 ]
Kim, Hak Hee [1 ,2 ]
Choi, Woo Jung [1 ,2 ]
Chae, Eun Young [1 ,2 ]
Shin, Hee Jung [1 ,2 ]
Cha, Joo Hee [1 ,2 ]
机构
[1] Univ Ulsan, Dept Radiol, Coll Med, 88, Olymp ro 43 gil, Seoul 05505, South Korea
[2] Univ Ulsan, Res Inst Radiol, Asan Med Ctr, Coll Med, 88, Olymp ro 43 gil, Seoul 05505, South Korea
关键词
Breast cancer; Shear-wave elastography; Molecular subtype; Lymph node metastasis; PROGNOSTIC-FACTORS; ULTRASOUND; STIFFNESS; BENIGN; MASSES; PERFORMANCE; DIAGNOSIS; WOMEN; SWE;
D O I
10.1016/j.clinimag.2023.06.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To examine correlations between shear-wave elastography (SWE) parameters with molecular subtype and axillary lymph node (LN) status of breast cancer. Methods: We retrospectively analyzed 545 consecutive women (mean age, 52.7 & PLUSMN; 10.7 years; range, 26-83) with breast cancer who underwent preoperative breast ultrasound with SWE between December 2019 and January 2021. SWE parameters (Emax, Emean, and Eratio) and the histopathologic information from surgical specimens including histologic type, histologic grade, size of invasive cancer, hormone receptor and HER2 status, Ki-67 proliferation index, and axillary LN status were analyzed. The relationships between SWE parameters and his-topathologic findings were analyzed using an independent sample t-test, one-way ANOVA test with Tukey's post hoc test, and logistic regression analyses. Results: Higher stiffness values of SWE were associated with larger lesion size (>20 mm) on ultrasound, high histologic grade, larger invasive cancer size (>20 mm), high Ki-67, and axillary LN metastasis. Emax and Emean were the lowest in the luminal A-like subtype, and all three parameters were the highest in the triple-negative subtype. Lower value of Emax was independently associated with the luminal A-like subtype (P = 0.04). Higher value of Emean was independently associated with axillary LN metastasis for tumors & LE; 20 mm (P = 0.03). Conclusion: Increases in the tumor stiffness values on SWE were significantly associated with aggressive histo-pathologic features of breast cancer. Lower stiffness values were associated with the luminal A-like subtype, and tumors with higher stiffness values were associated with axillary LN metastasis in small breast cancers.
引用
收藏
页码:190 / 199
页数:10
相关论文
共 50 条
  • [21] Correlation between the intrinsic subtype and diagnostic methods of axillary lymph node metastasis in primary breast cancer
    Feng, Yu
    Wang, Yunchao
    Zhao, Xia
    Mu, Ying
    Lv, Shuzhen
    Li, Yanping
    EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 2018, 39 (06) : 921 - 925
  • [22] Shear wave elastography of the breast-Immunohistopathology and molecular subtype comparisons
    Clements, Natalie N.
    Doherty, Colin S.
    SONOGRAPHY, 2025, 12 (01) : 32 - 48
  • [23] Lymphangiogenesis in Breast Cancer Correlates with Matrix Stiffness on Shear-Wave Elastography
    Cha, Yoon Jin
    Youk, Ji Hyun
    Kim, Baek Gil
    Jung, Woo Hee
    Cho, Nam Hoon
    YONSEI MEDICAL JOURNAL, 2016, 57 (03) : 599 - 605
  • [24] EVALUATION OF AXILLARY LYMPH NODE STATUS IN BREAST CANCER WITH MRI
    Goro Yoshimura Takeo Sakurai Syoji Oura Takaomi Suzuma Takeshi Tamaki Qifeng YangDepartment of Surgery Kihoku Hospital Wakayama Medical College Katsuragi Itogun Wakayama Japan
    中国现代普通外科进展, 1999, (03) : 38 - 44
  • [25] Evaluation of axillary lymph node status in breast cancer with MRI
    Yoshimura G.
    Sakurai T.
    Oura S.
    Suzuma T.
    Tamaki T.
    Umemura T.
    Kokawa Y.
    Yang Q.
    Breast Cancer, 1999, 6 (3) : 249 - 258
  • [26] Axillary Lymph Node Status in Breast Cancer a comparative study
    Chohan, M. Zahid Akbar
    Malik, Javed
    Ahmad, Zeeshan
    Crawford, Derek
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2015, 9 (01): : 128 - 130
  • [27] Whole sentinel lymph node analysis by a molecular assay predicts axillary node status in breast cancer
    Ohi, Y.
    Umekita, Y.
    Sagara, Y.
    Rai, Y.
    Yotsumoto, D.
    Matsukata, A.
    Baba, S.
    Tamada, S.
    Matsuyama, Y.
    Ando, M.
    Sagara, Y.
    Sasaki, M.
    Tsuchimochi, S.
    Tanimoto, A.
    Sagara, Y.
    BRITISH JOURNAL OF CANCER, 2012, 107 (08) : 1239 - 1243
  • [28] Whole sentinel lymph node analysis by a molecular assay predicts axillary node status in breast cancer
    Y Ohi
    Y Umekita
    Y Sagara
    Y Rai
    D Yotsumoto
    A Matsukata
    S Baba
    S Tamada
    Y Matsuyama
    M Ando
    Y Sagara
    M Sasaki
    S Tsuchimochi
    A Tanimoto
    Y Sagara
    British Journal of Cancer, 2012, 107 : 1239 - 1243
  • [29] Correlation of shear-wave elastography stiffness and apparent diffusion coefficient values with tumor characteristics in breast cancer
    Kwon, Mi-ri
    Youn, Inyoung
    Ko, Eun Sook
    Choi, Seon-Hyeong
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [30] Correlation of Shear-Wave Elastography and Apparent Diffusion Coefficient Values in Breast Cancer and Their Relationship with the Prognostic Factors
    Orguc, Sebnem
    Acar, Cagdas Riza
    DIAGNOSTICS, 2022, 12 (12)