Fast Quantitative Magnetic Resonance Imaging Evaluation of Hydrocephalus Using 3-Dimensional Fluid-Attenuated Inversion Recovery: Initial Experience

被引:0
|
作者
Goo, Hyun Woo [1 ,2 ]
Park, Sang Hyub
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, 88,Olymp Ro 43 Gil, Seoul 05505, South Korea
[2] Univ Ulsan, Res Inst Radiol, Asan Med Ctr, Coll Med, 88,Olymp Ro 43 Gil, Seoul 05505, South Korea
关键词
brain ventricular system; hydrocephalus; image segmentation; magnetic resonance imaging; volume measurement; VENTRICULAR VOLUME; MRI; FLAIR;
D O I
10.1097/RCT.0000000000001539
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: This study aimed to demonstrate the initial experience of using fast quantitative magnetic resonance imaging (MRI) to evaluate hydrocephalus. Methods: A total of 109 brain MRI volumetry examinations (acquisition time, 7 minutes 30 seconds) were performed in 72 patients with hydrocephalus. From the measured ventricular system and brain volumes, ventricle-brain volume percentage was calculated to standardize hydrocephalus severity (processing time, <5 minutes). The obtained values were categorized into no, mild, and severe based on the fronto-occipital horn ratio (FOHR) and the ventricle-brain volume percentages reported in the literature. The measured volumes and percentages were compared between patients with mild hydrocephalus and those with severe hydrocephalus. The diagnostic performance of brain hydrocephalus MRI volumetry was evaluated using receiver operating characteristic curve analysis. Results: Ventricular volumes and ventricle-brain volume percentages were significantly higher in in patients with severe hydrocephalus than in those with mild hydrocephalus (FOHR-based severity: 352.6 +/- 165.6 cm(3) vs 149.1 +/- 78.5 cm(3), P < 0.001, and 26.8% [20.8%-33.1%] vs 12.1% +/- 6.0%, P < 0.001; percentage-based severity: 359.5 +/- 143.3 cm3 vs 137.0 +/- 62.9 cm(3), P < 0.001, and 26.8% [21.8%-33.1%] vs 11.3% +/- 4.2%, P < 0.001, respectively), whereas brain volumes were significantly lower in patients with severe hydrocephalus than in those with mild hydrocephalus (FOHR-based severity: 878.1 +/- 363.5 cm(3) vs 1130.1 cm(3) [912.1-1244.2 cm(3)], P = 0.006; percentage-based severity: 896.2 +/- 324.6 cm3 vs 1142.3 cm(3) [944.2-1246.6 cm(3)], P = 0.005, respectively). The ventricle-brain volume percentage was a good diagnostic parameter for evaluating the degree of hydrocephalus (area under the curve, 0.855; 95% confidence interval, 0.719-0.990; P < 0.001). Conclusions: Brain MRI volumetry can be used to evaluate hydrocephalus severity and may provide guide interpretation because of its rapid acquisition and postprocessing times.
引用
收藏
页码:292 / 297
页数:6
相关论文
共 50 条
  • [31] Three-Dimensional Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging in Sudden Sensorineural Hearing Loss: Correlations With Audiologic and Vestibular Testing
    Ryu, In Sun
    Yoon, Tae Hyun
    Ahn, Joong Ho
    Kang, Woo Seok
    Choi, Byung Se
    Lee, Jeong Hyun
    Shim, Myung Joo
    OTOLOGY & NEUROTOLOGY, 2011, 32 (08) : 1205 - 1209
  • [32] Diffusion-weighted and fluid-attenuated inversion recovery magnetic resonance imaging as sensitive and early indicators of hippocampal injury
    Golomb, MR
    Lev, MH
    LeSueur, LL
    Rosenberger, PB
    ANNALS OF NEUROLOGY, 1998, 44 (03) : 549 - 549
  • [33] Problems With Diagnosis by Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging in Patients With Acute Aneurysmal Subarachnoid Hemorrhage Commentary
    Han, Dae Hee
    Tanaka, Yuichi
    NEUROLOGIA MEDICO-CHIRURGICA, 2010, 50 (07) : 537 - 537
  • [34] Suppression of inner ear signal intensity on fluid-attenuated inversion recovery magnetic resonance imaging in cats with vestibular disease
    Everest, Stephen
    Monteith, Gabrielle
    Gaitero, Luis
    Samarani, Francesca
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2023, 25 (04)
  • [35] Importance of Contrast-Enhanced Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging in Various Intracranial Pathologic Conditions
    Lee, Eun Kyoung
    Lee, Eun Ja
    Kim, Sungwon
    Lee, Yong Seok
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (01) : 127 - 141
  • [36] Yield of fluid-attenuated inversion recovery in drug-resistant focal epilepsy with noninformative conventional magnetic resonance imaging
    Taillibert, S
    Oppenheim, C
    Baulac, M
    Dormont, D
    Marsault, C
    Cabanis, EA
    Tourbah, A
    EUROPEAN NEUROLOGY, 1999, 41 (02) : 64 - 72
  • [37] A preliminary study of fluid-attenuated inversion recovery and diffusion magnetic resonance imaging in comatose survivors following cardiac resuscitation
    Wijdicks, EFM
    Miller, GM
    Campeau, NG
    ANNALS OF NEUROLOGY, 2000, 48 (03) : 458 - 458
  • [38] Fluid-attenuated inversion recovery (FLAIR) for assessment of cerebral infarction - Initial clinical experience in 50 patients
    BrantZawadzki, M
    Atkinson, D
    Detrick, M
    Bradley, WG
    Scidmore, G
    STROKE, 1996, 27 (07) : 1187 - 1191
  • [39] Synthetic double inversion recovery imaging in brain MRI: quantitative evaluation and feasibility of synthetic MRI and a comparison with conventional double inversion recovery and fluid-attenuated inversion recovery sequences
    Odgerel Zorigt
    Takahito Nakajima
    Yuka Kumasaka
    Akiko Jingu
    Yoshito Tsushima
    BMC Medical Imaging, 22
  • [40] Analysis of elements in a minimal amount of temporomandibular joint fluid on fluid-attenuated inversion recovery magnetic resonance images
    Hanyuda, Hitoshi
    Otonari-Yamamoto, Mika
    Imoto, Kenichi
    Sakamoto, Junichiro
    Kodama, Sayaka
    Kamio, Takashi
    Sano, Tsukasa
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 115 (01): : 114 - 120