Design of intermittent continuous measurement of radon concentration in water

被引:1
|
作者
Hu, Tao [1 ]
Yuan, Shuai [1 ]
Mo, Yixiang [1 ]
Lin, Fen [1 ]
Fan, Zhongkai [2 ]
Liu, Shuaibin [1 ]
Xie, Ruomei [1 ]
Yi, Haibo [1 ]
Li, Huiying [1 ]
Liu, Zhipeng [1 ]
Sun, Jiale [1 ]
Wu, Jiulin [1 ]
Chen, Linquan [1 ]
Wang, Luwei [1 ]
Yuan, Hongzhi [1 ]
Tan, Yanliang [1 ,3 ]
机构
[1] Hengyang Normal Univ, Coll Phys & Elect Engn, Hengyang 421008, Hunan, Peoples R China
[2] Univ South China, Sch Nucl Sci & Technol, Hengyang 421001, Hunan, Peoples R China
[3] Hengyang Normal Univ, Hengyang, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Water radon concentration; Intermittent continuous measurement; Bubbling method; RAD7; RN-222;
D O I
10.1016/j.apradiso.2023.110894
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The U.S. Environmental Protection Agency established the maximum contaminant level limit for radon concentration in drinking water as 11.1 Bq L-1. A new device based on the bubbling method with a 290 mL sample bottle was designed for intermittent continuous measurement of water radon concentration. A STM32 is used to control the switch of the water pump and the valves. The Water-Radon-Measurement software written in C# is to connect RAD7 and calculate the water radon concentration automatically.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] ELECTRET METHOD FOR CONTINUOUS MEASUREMENT OF THE CONCENTRATION OF RADON IN WATER
    DUA, SK
    HOPKE, PK
    KOTRAPPA, P
    HEALTH PHYSICS, 1995, 68 (01): : 110 - 114
  • [2] Continuous radon gas measurement along with intermittent radon- and thoron-progeny measurement for one year
    Kobayashi, T
    Takaku, Y
    RADON AND THORON IN THE HUMAN ENVIRONMENT, 1998, : 418 - 423
  • [3] MEASUREMENT OF RADON CONCENTRATION IN WATER USING THE PORTABLE RADON SURVEY METER
    Yokoyama, S.
    Mori, N.
    Shimo, M.
    Fukushi, M.
    Ohnuma, S.
    RADIATION PROTECTION DOSIMETRY, 2011, 146 (1-3) : 23 - 26
  • [4] Fast measurement of radon concentration in water with Lucas cell
    Machaj, B
    Bartak, J
    NUKLEONIKA, 2004, 49 (01) : 29 - 31
  • [5] Measurement of radon concentration in northern Greece ground water
    Savidou, A
    Zouridakis, N
    FRESENIUS ENVIRONMENTAL BULLETIN, 2001, 10 (04): : 411 - 413
  • [6] CONTINUOUS RADON CONCENTRATION MONITORING
    CATHEY, L
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1978, 49 (12): : 1670 - 1674
  • [7] Measurement of Radon Concentration in Drinking Water in Bhiwani District of Haryana
    Duggal, Vikas
    Sharma, Samriti
    Srivastava, Ajay Kumar
    Mehra, Rohit
    JOURNAL OF THE GEOLOGICAL SOCIETY OF INDIA, 2018, 91 (06) : 700 - 703
  • [8] Measurement of Radon - 222 Concentration Levels in Spring Water in Iraq
    Yousuf, R. M.
    Husain, M. M.
    Najam, L. A.
    JORDAN JOURNAL OF PHYSICS, 2009, 2 (02): : 89 - 93
  • [9] Measurement of Radon Concentration in Drinking Water in Bhiwani District of Haryana
    Vikas Duggal
    Samriti Sharma
    Ajay Kumar Srivastava
    Rohit Mehra
    Journal of the Geological Society of India, 2018, 91 : 700 - 703
  • [10] A new-designed system for continuous measurement of radon in water
    He, Chunyu
    Zeng, Zhi
    Zhang, Lei
    Wang, Yunxiang
    Guo, Qiuju
    APPLIED RADIATION AND ISOTOPES, 2022, 187