Comparison of BACTEC versus conventional enrichment medium for peritoneal dialysate fluid culture

被引:1
|
作者
Tan, Shanti Shi Hui [1 ]
Lee, Karen [2 ]
Deepak, Rama Narayana [2 ]
Tan, Si Hui [3 ]
Lim, Eng Kuang [1 ]
Liu, Allen Yan Lun [1 ]
机构
[1] Khoo Teck Puat Hosp, Dept Gen Med, Singapore, Singapore
[2] Khoo Teck Puat Hosp, Dept Lab Med, Singapore, Singapore
[3] Khoo Teck Puat Hosp, Renal Ctr, Singapore, Singapore
关键词
peritoneal dialysis; peritonitis; end-stage kidney disease; bacteriological culture; BACTEC system; blood culture technique; direct inoculation; EFFLUENT; BACT/ALERT; DIAGNOSIS; RECOVERY; SYSTEMS; GROWTH;
D O I
10.5414/CN110788
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Bacterial peritonitis remains a significant cause of mortality in patients on peritoneal dialysis (PD). Early detection of causative organisms and targeted antimicrobial treatment allow for better clinical outcomes. This study compares bacterial growth results from peritoneal dialysate in the BACTEC blood culture system vs. conventional culture. Materials and methods: We conducted a prospective study on 46 patients with 63 consecutive episodes of suspected PD peritonitis between August 2020 and August 2021. PD dialysate was simultaneously sent to the laboratory in both BACTEC and sterile bottles. BACTEC bottles were incubated in the BD BACTEC FX system for 5 days. PD effluent transported from the sterile bottles was centrifuged at 3,000 rpm for 15 minutes; the supernatant was inoculated into cooked-meat broth for enrichment. Both incubation methods were extended to 14 days if microorganisms were seen on the Gram-stained smear. Recovery of isolated micro-organisms and time to detection (TTD) were compared. Results: 26 episodes of suspected PD peritonitis based on clinical criteria were identified during the study period. The sensitivity of the BACTEC and the conventional culture methods was 50% and 42.3%, respectively (p = 0.45). Seven samples had partial concordance or discordant results. McNemar's.2-test revealed no statistical difference between either method (p = 0.45). TTD was 18.9 +/- 24.4 hours via the BACTEC method vs. 37 +/- 16.5 hours in conventional cultures (p = 0.014). Conclusion: The comparable sensitivities and similar yield in identifying pathogens could be due to the enrichment medium and prolonged incubation period. The shorter TTD for the BACTEC method could facilitate earlier confirmation of bacteriological diagnosis and subsequent treatment strategies.
引用
收藏
页码:18 / 23
页数:6
相关论文
共 50 条
  • [21] COMPARISON OF A RADIOMETRIC METHOD (BACTEC) AND CONVENTIONAL CULTURE MEDIA FOR RECOVERY OF MYCOBACTERIA FROM SMEAR-NEGATIVE SPECIMENS
    MORGAN, MA
    HORSTMEIER, CD
    DEYOUNG, DR
    ROBERTS, GD
    JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (02) : 384 - 388
  • [22] PERITONEAL-FLUID AND INFERTILITY - A COMPARISON OF INVITRO FERTILIZATION OF OOCYTES IN PERITONEAL-FLUID AND B2-MENEZO MEDIUM
    WITTEMER, C
    MENARD, A
    DELLENBACH, P
    HUMAN REPRODUCTION, 1990, 5 (08) : 955 - 958
  • [23] Bacterial contamination of embryo culture medium in conventional in vitro fertilisation versus ICSI
    Berkes-Bara, E.
    Nemes, A.
    Beata, D.
    Joo, K.
    Murber, A.
    Urbancsek, J.
    Fancsovits, P.
    HUMAN REPRODUCTION, 2023, 38
  • [24] Comparison of cytokines in the peritoneal fluid and conditioned medium of adolescents and adults with and without endometriosis
    Bailey, Amelia P.
    Hill, Abby S.
    Beste, Michael T.
    Cook, Christi D.
    Sarda, Vishnudas
    Laufer, Marc R.
    Isaacson, Keith B.
    Griffith, Linda G.
    Missmer, Stacey A.
    AMERICAN JOURNAL OF REPRODUCTIVE IMMUNOLOGY, 2021, 85 (03)
  • [25] Comparison of BacT/Alert blood culture bottles with lytic media for culture of peritoneal dialysis fluid
    Wust, J
    vonGraevenitz, A
    INFECTION, 1995, 23 (06) : 378 - 379
  • [26] A COMPARISON OF IMMUNOMAGNETIC SEPARATION PLUS ENRICHMENT WITH CONVENTIONAL SALMONELLA CULTURE IN THE EXAMINATION OF RAW SAUSAGES
    COLEMAN, DJ
    NYE, KJ
    CHICK, KE
    GAGG, CM
    LETTERS IN APPLIED MICROBIOLOGY, 1995, 21 (04) : 249 - 251
  • [27] Comparison of BACTEC 9120 and Conventional Blood Culture Systems for Isolation of Microorganisms from Blood and Other Sterile Body Fluids
    Maham, Said
    Shirvani, Fariba
    Jahromi, Mana Hadipour
    Fallah, Fatemeh
    Razavi, Seid Sajad
    Nikfarjam, Ali
    Rahbar, Mohammad
    JOURNAL OF PURE AND APPLIED MICROBIOLOGY, 2012, 6 (04): : 2039 - 2044
  • [28] Comparison of peritoneal fluid culture results from adults and children undergoing CAPD
    Yinnon, AM
    Gabay, D
    Raveh, D
    Schlesinger, Y
    Slotki, I
    Attias, D
    Rudensky, B
    PERITONEAL DIALYSIS INTERNATIONAL, 1999, 19 (01): : 51 - 55
  • [29] Clinical Comparison of Conventional and Mobile Endockscope Videocystoscopy Using an Air or Fluid Medium
    Dutta, Rahul
    Yoon, Renai
    Patel, Roshan M.
    Spradling, Kyle
    Okhunov, Zhamshid
    Sohn, William
    Lee, Hak J.
    Landman, Jaime
    Clayman, Ralph V.
    JOURNAL OF ENDOUROLOGY, 2017, 31 (06): : 593 - 597
  • [30] Longitudinal Analysis of Fluid and Solute Transport: A More Biocompatible Versus a Conventional Peritoneal Dialysis Solution
    Annemieke, Coester
    Watske, Smit
    Dirk, Struijk
    Raymond, Krediet
    BLOOD PURIFICATION, 2009, 28 (04) : 312 - 313