VNA Calibration using Coaxial Air Lines with Two Plug Connectors

被引:1
|
作者
Gellersen, Frauke [1 ]
Kuhlmann, Karsten [1 ]
Rausche, Florian [1 ]
机构
[1] Phys Tech Bundesanstalt, Braunschweig, Germany
关键词
Calibration; coaxial air line; TRL; metrology;
D O I
10.23919/EuMC58039.2023.10290291
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work a two-port VNA calibration is performed using 3.5 mm coaxial air lines with plug connectors on both sides. The measurements are evaluated using a Thru-Reflect-Line calibration. Working only with plug connectors during calibration helps to minimize the connector effects and to improve the accuracy of the calibration. To be able to make a Thru connection with zero length and for the characterization of devices with a jack connector, a multi-gender test port adapter is used. The obtained measurement results are compared to a different calibration where a set of air lines with plug and jack connectors and a multi line evaluation were used.
引用
收藏
页码:608 / 611
页数:4
相关论文
共 50 条
  • [22] Millimeter-wave VNA Calibration using a CMOS Transmission Line with Distributed Switches
    Chien, Jun-Chau
    2022 IEEE RADIO FREQUENCY INTEGRATED CIRCUITS SYMPOSIUM (RFIC), 2022, : 283 - 286
  • [23] Calibration of Broadband Antenna Using the Standard Field Method With VNA Considering the Near Field
    Ishigami, Shinobu
    Kawamata, Ken
    Minegishi, Shigeki
    PROCEEDINGS OF THE 2024 IEEE JOINT INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, SIGNAL & POWER INTEGRITY: EMC JAPAN/ASIAPACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, EMC JAPAN/APEMC OKINAWA 2024, 2024, : 119 - 121
  • [24] COAXIAL POWER METER CALIBRATION USING A WAVEGUIDE STANDARD
    ENGEN, GF
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION C-ENGINEERING AND INSTRUMENTATION, 1966, C 70 (02): : 127 - +
  • [25] Characterization Scattering Parameters of Coaxial air-lines by Physical Measurements
    Liang, HanChen
    6TH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2010, 7544
  • [26] Two coaxial lines cross-coupled to a rectangular waveguide
    Park, M. Y.
    Eom, H. J.
    IET MICROWAVES ANTENNAS & PROPAGATION, 2008, 2 (01) : 10 - 14
  • [27] Paracatadioptric camera calibration using lines
    Barreto, JP
    Araujo, H
    NINTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS I AND II, PROCEEDINGS, 2003, : 1359 - 1365
  • [28] Cylindrical sensor calibration using lines
    Smadja, L
    Benosman, R
    Devars, J
    ICIP: 2004 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1- 5, 2004, : 1851 - 1854
  • [29] A CALIBRATION PROCEDURE FOR TWO-PORT VNA WITH THREE MEASUREMENT CHANNELS BASED ON T-MATRIX
    Zhao, W.
    Qin, H. -B.
    Qiang, L.
    PROGRESS IN ELECTROMAGNETICS RESEARCH LETTERS, 2012, 29 : 35 - 42
  • [30] Demonstration of TRL Calibration Performance on mmW PCBs using WSMP Connectors
    Ozturk, Yagmur
    Nahar, Niru K.
    Sertel, Kubilay
    2023 100TH ARFTG MICROWAVE MEASUREMENT CONFERENCE, ARFTG, 2023,