Effect of material type, torque value, and sterilization on linear displacements of a scan body: An in vitro study

被引:9
|
作者
Diker, Emre [1 ,2 ]
Terzioglu, Hakan [2 ]
Gouveia, Diogo N. M. [3 ]
Donmez, Mustafa Borga [4 ,5 ,8 ]
Seidt, Jeremy [3 ,6 ]
Yilmaz, Burak [3 ,4 ,7 ]
机构
[1] Med Dis Dent Clin, Private Practice, Ankara, Turkiye
[2] Ankara Univ, Fac Dent, Dept Prosthodont, Ankara, Turkiye
[3] Ohio State Univ Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH USA
[4] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[5] Istinye Univ, Fac Dent, Dept Prosthodont, I?stanbul, Turkiye
[6] Ohio State Univ Coll Engn, Dept Mech & Aerosp Engn, Columbus, OH USA
[7] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[8] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
关键词
linear displacement; polyetheretherketone; scan body; sterilization; titanium; torque value; AXIAL DISPLACEMENT; IMPLANT IMPRESSION; SCREW; ABUTMENTS; CONNECTION; TRUENESS; CROWNS;
D O I
10.1111/cid.13187
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: There is limited knowledge on the effect of scan body (SB) material type, torque value, and sterilization on linear displacements of implant SBs. Purpose: To evaluate the effect of material type, torque value, and sterilization on linear displacements of SBs during screw tightening by using digital image correlation (DIC) analysis. Materials and Methods: One polyetheretherketone (PEEK, Zfx Intraoral Scan Body) and one titanium SB (Ti, MPS Zimmer Scanbody R1410) were tightened with 5 Ncm torque on two implants (Zimmer TSV circle divide 4.7 mm) by using a digital torque limiting device. SBs' initial spatial positions relative to the implants were recorded by using 3D DIC technique. Measurements were repeated after initially increasing torque value to 10 Ncm and then to 15 Ncm, and these steps were repeated for a total of 10 PEEK and 10 Ti SBs on both implants (n = 20). All SBs were then sterilized 25 times by using an autoclave (STATIM 5000 S G4) according to manufacturer's recommendations and all measurements were repeated. Linear displacements on three axes were calculated for each SB with increasing torque values (from 5 to 10 Ncm and from 10 to 15 Ncm) before and after sterilization. SB displacements within each torque value-sterilization pair were compared by using Mann-Whitney U test, whereas Wilcoxon signed-rank test was used to compare SB displacements within each material-torque value pair between conditions and within each material-sterilization pair between torque values (alpha = 0.05). Results: On x-axis, PEEK SBs had higher displacements than Ti SBs (p < 0.001), whereas sterilization (p <= 0.028) and 15 Ncm torque application (p <= 0.006) led to higher displacements of PEEK SBs. On y-axis, PEEK SBs had higher displacements than Ti SBs with 15 Ncm torque application (p <= 0.033). A total of 15 Ncm torque-applied PEEK SBs and 10 Ncm torque-applied Ti SBs had higher displacements after sterilization (p <= 0.028). Application of 15 Ncm torque led to higher displacements regardless of the material (p <= 0.002). On z-axis, PEEK SBs had higher displacements (p <= 0.015), except for 10 Ncm torque-applied sterilized SBs (p = 0.102). With 10 Ncm torque application, sterilization decreased the displacement values of PEEK SBs (p = 0.044). Greater displacements were observed with 10 Ncm torque-applied Ti SBs before sterilization and 15 Ncm torque-applied PEEK SBs after sterilization (p <= 0.033). Conclusions: Axial displacement of SBs was affected by material type, torque value, and sterilization. Ti SBs mostly had lower displacements than PEEK SBs. Application of 15 Ncm torque to tested PEEK SBs should be refrained from and a calibrated tightening tool may enable the application of 10 Ncm or lower torque values for lower displacements. Sterilization generally increased PEEK SB displacements.
引用
收藏
页码:419 / 425
页数:7
相关论文
共 50 条
  • [1] Vertical Deviation Caused by Tightening Torque on Implant Scan Body: An In Vitro Study
    Shi, Xiaorui
    Liu, Xinran
    Liu, Shiming
    Wang, Miaozhen
    Liu, Feng
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (05) : 653 - 659
  • [2] Post sterilization of intraoral scan body and the effect it has on the axes and distances between three adjacent implants: in-vitro study
    Ben-Izhack, Gil
    Lugassy, Diva
    Rosner, Ofir
    Nissan, Joseph
    Rachmiel, Shir
    Khoury, Yara
    Shely, Asaf
    BMC ORAL HEALTH, 2024, 24 (01):
  • [3] Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study
    Cakmak, Gulce
    Yilmaz, Hakan
    Santos, Alejandro Trevino
    Kokat, Ali Murat
    Yilmaz, Burak
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 419 - 426
  • [4] Effect of supramucosal height of a scan body and implant angulation on the accuracy of intraoral scanning: An in vitro study
    Sicilia, Elena
    Lagreca, Gabriela
    Papaspyridakos, Panos
    Finkelman, Matthew
    Cobo, Juan
    Att, Wael
    Revilla-Leon, Marta
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1126 - 1134
  • [5] Displacement of scan body during screw tightening: A comparative in vitro study
    Kim, JungHan
    Son, KeunBaDa
    Lee, Kyu-Bok
    JOURNAL OF ADVANCED PROSTHODONTICS, 2020, 12 (05): : 307 - 315
  • [6] Effect of heat sterilization and chemical method of sterilization on the polyvinyl siloxane impression material. A comparative study
    Asopa, Swati Joshi
    Padiyar, U. Narendra
    Verma, Sumit
    Suri, Prerna
    Somayaji, Nagaveni S.
    Radhakrishnan, Indu Cherangapadath
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2020, 9 (03) : 1348 - 1353
  • [7] The Effect of Sterilization Methods of Endoscopic Instruments on the Body: A Study on Rat Model
    Hut, Adnan
    Yildirim, Dogan
    Donmez, Turgut
    Tatar, Cihad
    Mirapoglu, Semih
    Erdogan, Rukiye Nilgun
    Saglam, Zumrut Mine Isik
    Kilincaslan, Huseyin
    JOURNAL OF INVESTIGATIVE SURGERY, 2018, 31 (03) : 218 - 225
  • [8] Influence of different scan body design features and intraoral scanners on the congruence between scan body meshes and library files: An in vitro study
    Michelinakis, George
    Apostolakis, Dimitrios
    Nikolidakis, Dimitrios
    Lapsanis, George
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (02): : 454e1 - 454e11
  • [9] Effect of the Sterilization Method on the Performance of Collagen Type I on Chronic Wound Parameters In Vitro
    Wiegand, Cornelia
    Abel, Martin
    Ruth, Peter
    Wilhelms, Tim
    Schulze, Daniel
    Norgauer, Johannes
    Hipler, Uta-Christina
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 90B (02) : 710 - 719
  • [10] Accuracy of Impression Material During COVID-19 after Sterilization-In vitro Study
    Alhaddad, Abdulrahman Jafar
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (50B) : 241 - 246