Comprehensive Single-Platform Lipidomic/Metabolomic Analysis Using Supercritical Fluid Chromatography-Mass Spectrometry

被引:4
|
作者
Kozlov, Oleksandr [1 ]
Hancova, Eliska [1 ]
Cifkova, Eva [1 ]
Lisa, Miroslav [1 ]
机构
[1] Univ Hradec Kralove, Fac Sci, Dept Chem, Hradec Kralove 50003, Czech Republic
关键词
LIPIDOMIC ANALYSIS; HIGH-THROUGHPUT; METABOLOMICS;
D O I
10.1021/acs.analchem.3c04771
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Supercritical fluid chromatography (SFC) is a rapidly expanding technique in the analysis of nonpolar to moderately polar substances and, more recently, also in the analysis of compounds with higher polarity. Herein, we demonstrate a proof of concept for the application of a commercial SFC instrument with electrospray ionization-mass spectrometry (MS) detection as a platform for the comprehensive analysis of metabolites with the full range of polarities, from nonpolar lipids up to highly polar metabolites. The developed single-platform SFC-MS lipidomic/metabolomic method is based on two consecutive injections of lipid and polar metabolite extracts from biphase methyl tert-butyl ether extraction using a diol column and two different gradient programs of methanol-water-ammonium formate modifier. Detailed development of the method focused mainly on the pressure limits of the system, the long-term repeatability of results, and the chromatographic performance, including optimization of the flow rate program, modifier composition and gradient, and injection solvent selection. The developed method enabled fast and comprehensive analysis of lipids and polar metabolites from plasma within a 24 min cycle with two injections using a simple analytical platform based on a single instrument, column, and mobile phase. Finally, the results from SFC-MS analysis of polar metabolites were compared with widely established liquid chromatography MS analysis in metabolomics. The comparison showed different separation selectivity of metabolites using both methods and overall lower sensitivity of the SFC-MS due to the higher flow rate and worse chromatographic performance.
引用
收藏
页码:1320 / 1327
页数:8
相关论文
共 50 条
  • [21] Supercritical fluid extraction coupled with chromatography-mass spectrometry: Hair analysis. Chromatography-mass spectrometry data processing using the CODA mathematical algorithm
    Bogdanov, A.V.
    Glazkov, I.N.
    Revel'skii, I.A.
    Journal of Analytical Chemistry, 2007, 62 (01): : 63 - 67
  • [22] Supercritical fluid extraction coupled with chromatography-mass spectrometry: Hair analysis. Chromatography-mass spectrometry data processing using the CODA mathematical algorithm
    A. V. Bogdanov
    I. N. Glazkov
    I. A. Revel’skii
    Journal of Analytical Chemistry, 2007, 62 : 63 - 67
  • [23] Supercritical fluid extraction coupled with chromatography-mass spectrometry: Hair analysis. Chromatography-mass spectrometry data processing using the CODA mathematical algorithm
    Bogdanov, A. V.
    Glazkov, I. N.
    Revel'skii, I. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 62 (01) : 63 - 67
  • [24] Analysis of fifteen estrogen metabolites using packed column supercritical fluid chromatography-mass spectrometry
    Xu, X
    Roman, JM
    Veenstra, TD
    Van Anda, J
    Ziegler, RG
    Issaq, HJ
    ANALYTICAL CHEMISTRY, 2006, 78 (05) : 1553 - 1558
  • [25] Comprehensive analysis of vitamin D3 impurities in oily drug products using supercritical fluid chromatography-mass spectrometry
    Jambo, Hugues
    Dispas, Amandine
    Perez-Mayan, Leticia
    Rodriguez, Isaac
    Ziemons, Eric
    Hubert, Philippe
    DRUG TESTING AND ANALYSIS, 2024, 16 (07) : 692 - 707
  • [26] SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY - A POTENTIALLY USEFUL TECHNIQUE FOR PORPHYRIN ANALYSIS
    WRIGHT, BW
    SMITH, RD
    ORGANIC GEOCHEMISTRY, 1989, 14 (02) : 227 - 232
  • [27] Validation of lipidomic analysis of human plasma and serum by supercritical fluid chromatography–mass spectrometry and hydrophilic interaction liquid chromatography–mass spectrometry
    Denise Wolrab
    Michaela Chocholoušková
    Robert Jirásko
    Ondřej Peterka
    Michal Holčapek
    Analytical and Bioanalytical Chemistry, 2020, 412 : 2375 - 2388
  • [28] SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY OF CAROTENOID-PIGMENTS
    FREW, NM
    JOHNSON, CG
    BROMUND, RH
    ACS SYMPOSIUM SERIES, 1988, 366 : 208 - 228
  • [29] ANALYTICAL APPLICATIONS OF CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY
    KALINOSKI, HT
    UDSETH, HR
    WRIGHT, BW
    SMITH, RD
    JOURNAL OF CHROMATOGRAPHY, 1987, 400 : 307 - 316
  • [30] ANALYSIS OF VETERINARY DRUGS USING SUPERCRITICAL FLUID CHROMATOGRAPHY AND SUPERCRITICAL FLUID CHROMATOGRAPHY MASS-SPECTROMETRY
    PERKINS, JR
    GAMES, DE
    STARTIN, JR
    GILBERT, J
    JOURNAL OF CHROMATOGRAPHY, 1991, 540 (1-2): : 257 - 270