Sectional strength design of a double-skin truss-reinforced composite shear wall

被引:4
|
作者
Han, Jianhong [1 ]
Shu, Ganping [2 ]
Qin, Ying [2 ]
Zhou, Guangen [3 ]
Zhou, Xiongliang [3 ]
机构
[1] Xinjiang Inst Engn, BIM & Intelligent Construct Ind Educ Integrat Res, Sch Civil Engn, Urumqi, Peoples R China
[2] Southeast Univ, Sch Civil Engn, Nanjing, Peoples R China
[3] Zhejiang Southeast Space Frame Grp Co Ltd, Hangzhou, Peoples R China
关键词
Double -skin composite shear wall; Truss connector; Shear strength; Flexural Strength; Design Proposal; SEISMIC BEHAVIOR; CONCRETE; PERFORMANCE;
D O I
10.1016/j.tws.2023.111377
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The double-skin truss-reinforced composite shear wall is an innovative element which comprises two steel plates, core concrete, concrete-filled steel tubes (CFSTs), which act as boundary members, and steel truss connectors. Truss connectors decrease the out-of-plane deformation that affects the steel plates, and due to the resultant connection and constraint effects, the truss connectors enhance the bearing capacity of the wall. This paper briefly introduces the quasi-static test of five full-scale rectangular double-skin truss-reinforced composite shear wall specimens. The specimen exhibited shear compression failure with an aspect ratio of 2.0, and flexure shear failure occurred when the aspect ratio exceeded 2.0. Based on the analysis of actual stress state of the steel web and actual working performance of the infilled concrete, the shear strength and flexure strength design formulas of double-skin truss-reinforced composite shear wall were established. Comparison results with 26 specimens demonstrate that the design formulas exhibit remarkable accuracy, as most errors are within 20 % and 25 %, respectively. Which provide a preliminary sectional strength design proposal for the double-skin truss-reinforced composite shear wall.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] The suitability of double-skin wall for climate in the high rise
    Xie, Zhenyu
    Li, Chao
    Zhan, Kuangyi
    ADVANCED BUILDING MATERIALS AND SUSTAINABLE ARCHITECTURE, PTS 1-4, 2012, 174-177 : 3120 - 3125
  • [22] Shear and tensile behaviors of headed stud connectors in double skin composite shear wall
    Yan, Jia-Bao
    Wang, Zhe
    Wang, Tao
    Wang, Xiao-Ting
    STEEL AND COMPOSITE STRUCTURES, 2018, 26 (06): : 759 - 769
  • [23] Experimental research on seismic behavior of double skin composite shear wall
    Guo, X. (guo-xiao-nong@tongji.edu.cn), 1636, Science Press (41):
  • [24] Experimental study on seismic behavior of double-skin composite wall with L-shaped connectors
    Chen, Lihua
    Yin, Chao
    Wang, Chenggang
    Liu, Yuming
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 174
  • [25] Data-driven shear strength prediction of steel reinforced concrete composite shear wall
    Huang, Peng
    Dai, Kuangyu
    Yu, Xiaohui
    MATERIALS TODAY COMMUNICATIONS, 2024, 38
  • [26] Impact of concrete strength on seismic behavior of T-shaped double-skin composite walls
    Qian, Kai
    He, Pan
    Deng, Ning
    Li, Honghao
    ENGINEERING STRUCTURES, 2021, 236
  • [27] Cyclic In-Plane Shear Behavior of Double-Skin Composite Walls in High-Rise Buildings
    Ji, Xiaodong
    Cheng, Xiaowei
    Jia, Xiangfu
    Varma, Amit H.
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (06)
  • [28] Experimental seismic behavior of T-shaped double skin composite wall with steel truss
    Han, Jianhong
    Shu, Ganping
    Qin, Ying
    Zhou, Guangen
    Zhou, Xiongliang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 184
  • [29] Seismic behavior of double-skin composite wall with L-shaped and C-shaped connectors
    Chen, Lihua
    Wang, Shiye
    Lou, Yu
    Xia, Dengrong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 160 : 255 - 270
  • [30] Finite element modeling of impact shear resistance of double skin composite wall
    Hossain, Khandaker M. A.
    Rafiei, Shahryar
    Lachemi, Mohamed
    Behdinan, Kamran
    Anwar, Muhammed S.
    THIN-WALLED STRUCTURES, 2016, 107 : 101 - 118